Validation Log 2025-12-15 03:23:05.812442 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN006990/mwtab/txt Study ID: ST004204 Analysis ID: AN006990 File format: txt Status: Contains Validation Issues Number of Issues: 11 Number of Warnings: 5 Number of Value Errors: 11 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "12 hours", for the subsection, "TREATMENT_DOSEDURATION", in the "TREATMENT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['h', 'weeks', 'days']. Ignore this when more complicated descriptions are required. Error: The value, "320℃", for the subsection, "CAPILLARY_TEMPERATURE", in the "MS" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "35psi", for the subsection, "DRY_GAS_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value, "3.5kV", for the subsection, "SPRAY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['kV']. Ignore this when more complicated descriptions are required. Error: The value, "0.2mL/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "40℃", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Warning: The "m/z" column at position 4 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Molecular Weight" column at position 2 in the METABOLITES table, matches a standard column name, "mass". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Lipidmaps_ID" column at position 7 in the METABOLITES table, matches a standard column name, "lm_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "RT [min]" column at position 3 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Lipidmaps_ID" column at position 7 in the METABOLITES table may have incorrect values. 90% or more of the values are the same, but 10% or less are different.