Validation Log 2026-01-11 07:45:25.813585 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN007306/mwtab/json Study ID: ST004372 Analysis ID: AN007306 File format: json Status: Contains Validation Issues Number of Issues: 13 Number of Warnings: 5 Number of Value Errors: 13 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "3500", in ["MS"]["CAPILLARY_VOLTAGE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "12l/min", in ["MS"]["DRY_GAS_FLOW"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value, "200", in ["MS"]["DRY_GAS_TEMP"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "175", in ["MS"]["FRAGMENT_VOLTAGE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V']. Ignore this when more complicated descriptions are required. Error: The value, "750", in ["MS"]["OCTPOLE_VOLTAGE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V']. Ignore this when more complicated descriptions are required. Error: The value, "35℃", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "20 µL", in ["CHROMATOGRAPHY"]["SAMPLE_INJECTION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "20℃", in ["CHROMATOGRAPHY"]["INJECTION_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Warning: The "KEGG" column at position 6 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "CAS ID" column at position 5 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "cas_number". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ChEBI" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "chebi_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ChEBI" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "chebi_id", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 0 CHEBI:15843 1 CHEBI:15551 Warning: The "RT" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.