Validation Log 2026-01-11 07:49:08.947012 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN007397/mwtab/json Study ID: ST004421 Analysis ID: AN007397 File format: json Status: Contains Validation Issues Number of Issues: 22 Number of Warnings: 14 Number of Value Errors: 21 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["INSTRUMENT_NAME"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["COLUMN_NAME"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["FLOW_GRADIENT"]. A legitimate value should be provided for this required key. Error: The value, "N/A", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "N/A", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["SOLVENT_A"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["SOLVENT_B"]. A legitimate value should be provided for this required key. Warning: The "NB_2024_029 - Blank_1_1" column at position 59 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "NB_2024_029 - Blank_1_2" column at position 60 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "NB_2024_039 - Blank_1" column at position 104 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "NB_2024_039 - Blank_2" column at position 105 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "NB_2024_039 - Blank_3" column at position 106 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "NB_2024_039 - Blank_4" column at position 107 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "NB_2025_015 - Blank_1" column at position 145 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "NB_2025_015 - Blank_2" column at position 146 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "NB_2025_015 - Blank_3" column at position 147 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "NB_2025_015 - Blank_4" column at position 148 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "NB_2025_015 - Blank_5" column at position 149 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "NB_2025_058 - Blank_1" column at position 186 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "NB_2025_058 - Blank_3" column at position 188 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "NB_2025_058 - Blank_4" column at position 189 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Error: The ["MS_METABOLITE_DATA"]["Metabolites"] table does not have a column for "Metabolite". It is likely misspelled or using a common incorrect substitute.