Validation Log 2026-05-03 07:50:58.505940 mwtab Python Library Version: 2.1.1 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN007610/mwtab/json Study ID: ST004530 Analysis ID: AN007610 File format: json Status: Contains Validation Issues Number of Issues: 9 Number of Warnings: 2 Number of Value Errors: 9 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "0, 8, 15 and 42 days", in ["SUBJECT"]["AGE_OR_AGE_RANGE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value, "Male and female", in ["SUBJECT"]["GENDER"] should be one of "Male", "Female", "Male, Female", "Hermaphrodite", or "N/A". Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["FLOW_GRADIENT"]. A legitimate value should be provided for this required key. You may have to ignore this error in certain situations. For example, SOLVENT_A for a GCMS experiment. Error: The value, "NA", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "NA", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["SOLVENT_A"]. A legitimate value should be provided for this required key. You may have to ignore this error in certain situations. For example, SOLVENT_A for a GCMS experiment. Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["SOLVENT_B"]. A legitimate value should be provided for this required key. You may have to ignore this error in certain situations. For example, SOLVENT_A for a GCMS experiment. Warning: The "HMDB" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "hmdb_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "HMDB" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "hmdb_id", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 0 NA1 1 NA2 2 NA3 4 HMDB0001548...7 16 HMDB0000149...19 17 HMDB0000243...20 28 HMDB0000060...31 32 HMDB0000243...35 41 HMDB0000060...44 45 HMDB0000149...48 46 HMDB0000532...49 48 HMDB0000112...51 58 HMDB0000532...61 78 HMDB0000112...81 86 HMDB0000224...89 94 HMDB0000168...97 100 HMDB0000812...103 101 HMDB0003402_1 103 HMDB0003402_2 106 HMDB0000168...109 107 HMDB0000812...110 108 HMDB0011745...111 110 HMDB0011745...113 111 HMDB0000182...114 127 HMDB0000224...130 140 HMDB0003418...143 143 HMDB0003418...146 146 HMDB0000660...149 147 HMDB0001266...150 149 HMDB0001266...152 151 HMDB0000660...154 155 HMDB0000182...158 171 HMDB0001548...174 186 HMDB0001078...189 187 HMDB0001401...190 188 HMDB0001078...191 189 HMDB0001401...192 192 HMDB0000296...195 195 HMDB0000296...198