Validation Log 2026-05-03 08:06:08.032195 mwtab Python Library Version: 2.1.1 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN008084/mwtab/txt Study ID: ST004781 Analysis ID: AN008084 File format: txt Status: Contains Validation Issues Number of Issues: 9 Number of Warnings: 3 Number of Value Errors: 9 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "Male and female", for the subsection, "GENDER", in the "SUBJECT" section should be one of "Male", "Female", "Male, Female", "Hermaphrodite", or "N/A". Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. You may have to ignore this error in certain situations. For example, SOLVENT_A for a GCMS experiment. Error: The value, "7.7mL/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "150-320", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "SOLVENT_A", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. You may have to ignore this error in certain situations. For example, SOLVENT_A for a GCMS experiment. Error: An empty value or a null value was detected for the subsection, "SOLVENT_B", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. You may have to ignore this error in certain situations. For example, SOLVENT_A for a GCMS experiment. Warning: The "quantitated m/z" column at position 4 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "KEGG" column at position 2 in the METABOLITES table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "retention time" column at position 3 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.