Validation Log 2026-05-24 08:09:06.008061 mwtab Python Library Version: 2.1.1 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN008117/mwtab/json Study ID: ST004800 Analysis ID: AN008117 File format: json Status: Contains Validation Issues Number of Issues: 11 Number of Warnings: 2 Number of Value Errors: 10 Number of Consistency Errors: 1 Number of Format Errors: 0 Issue Log: Error: The value, "300", in ["MS"]["CAPILLARY_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value in ["MS"]["DRY_GAS_FLOW"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value in ["MS"]["GAS_PRESSURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['psi', 'psig', 'bar', 'kPa']. Ignore this when more complicated descriptions are required. Error: The value, "300", in ["MS"]["ION_SOURCE_TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "300", in ["MS"]["SOURCE_TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "3500 V", in ["MS"]["SPRAY_VOLTAGE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['kV']. Ignore this when more complicated descriptions are required. Error: The value, "45", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: SUBJECT_SAMPLE_FACTORS section missing sample ID(s). The following IDs were found in the ["MS_METABOLITE_DATA"]["Data"] section but not in the SUBJECT_SAMPLE_FACTORS: "" Warning: The "Retention time" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Error: Column(s) with no name were found in the ["MS_METABOLITE_DATA"]["Data"] table. Warning: The "" column at position 38 in the ["MS_METABOLITE_DATA"]["Data"] table has all null values.