Validation Log 2026-06-14 08:06:45.227975 mwtab Python Library Version: 2.1.1 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN008250/mwtab/txt Study ID: ST004871 Analysis ID: AN008250 File format: txt Status: Contains Validation Issues Number of Issues: 26 Number of Warnings: 11 Number of Value Errors: 23 Number of Consistency Errors: 2 Number of Format Errors: 0 Issue Log: Error: An empty value or a null value was detected for the subsection, "PROJECT_COMMENTS", in the "PROJECT" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value, "22g to 45g", for the subsection, "WEIGHT_OR_WEIGHT_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['g', 'mg', 'kg', 'lbs']. Ignore this when more complicated descriptions are required. Error: The value, "NA", for the subsection, "HEIGHT_OR_HEIGHT_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['cm', 'in']. Ignore this when more complicated descriptions are required. Error: The value, "Male and female", for the subsection, "GENDER", in the "SUBJECT" section should be one of "Male", "Female", "Male, Female", "Hermaphrodite", or "N/A". Ignore this when more complicated descriptions are required. Error: The value, "high", for the subsection, "CAPILLARY_TEMPERATURE", in the "MS" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "-18-25", for the subsection, "CAPILLARY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "50", for the subsection, "DRY_GAS_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value, "-40", for the subsection, "FRAGMENT_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V']. Ignore this when more complicated descriptions are required. Error: The value, "520", for the subsection, "ION_SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "-4200", for the subsection, "ION_SPRAY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "520", for the subsection, "SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "50", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "Ambient", for the subsection, "INJECTION_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Error: The following metabolites in the, MS_METABOLITE_DATA table were not found in the METABOLITES table: "11_12 EET" "14_15 EET" "5_6 EET" "8_9 EET" Error: The following metabolites in the METABOLITES table were not found in the MS_METABOLITE_DATA table: "11,12 EET" "14,15 EET" "5,6 EET" "8,9 EET" Warning: The "refmet_name" column at position 2 in the METABOLITES table, matches a standard column name, "name". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ri" column at position 8 in the METABOLITES table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ri_type" column at position 9 in the METABOLITES table, matches a standard column name, "retention_index_type". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The standard column, "other_id", was found in the METABOLITES table as "other_id". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column. Warning: The "pubchem_id" column at position 3 in the METABOLITES table has all null values. Warning: The "inchi_key" column at position 4 in the METABOLITES table has all null values. Warning: The "kegg_id" column at position 5 in the METABOLITES table has all null values. Warning: The "other_id" column at position 6 in the METABOLITES table has all null values. Warning: The "other_id_type" column at position 7 in the METABOLITES table has all null values. Warning: The "ri" column at position 8 in the METABOLITES table has all null values. Warning: The "ri_type" column at position 9 in the METABOLITES table has all null values.