{ "cells": [ { "cell_type": "markdown", "source": [ "# Parsing PSS/e `*.RAW` Files" ], "metadata": {} }, { "cell_type": "markdown", "source": [ "**Originally Contributed by**: Clayton Barrows" ], "metadata": {} }, { "cell_type": "markdown", "source": [ "## Introduction" ], "metadata": {} }, { "cell_type": "markdown", "source": [ "An example of how to parse PSS/e files and create a `System` using [PowerSystems.jl](github.com/NREL-SIIP/PowerSystems.jl)" ], "metadata": {} }, { "cell_type": "markdown", "source": [ "### Dependencies" ], "metadata": {} }, { "outputs": [], "cell_type": "code", "source": [ "using PowerSystems\n", "using TimeSeries" ], "metadata": {}, "execution_count": 1 }, { "cell_type": "markdown", "source": [ "### Fetch Data\n", "PowerSystems.jl links to some test data that is suitable for this example.\n", "Let's download the test data" ], "metadata": {} }, { "outputs": [], "cell_type": "code", "source": [ "PowerSystems.download(PowerSystems.TestData; branch = \"master\")\n", "base_dir = dirname(dirname(pathof(PowerSystems)));" ], "metadata": {}, "execution_count": 2 }, { "cell_type": "markdown", "source": [ "### Create a `System`" ], "metadata": {} }, { "outputs": [ { "name": "stdout", "output_type": "stream", "text": [ "[ Info: The PSS(R)E parser currently supports buses, loads, shunts, generators, branches, transformers, and dc lines\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: The following fields in LOAD are missing: INTRPT\n", "[ Info: Switched shunt converted to fixed shunt, with default value gs=0.0\n", "[ Info: angmin and angmax values are 0, widening these values on branch 32 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 29 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 1 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 54 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 78 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 81 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 101 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 2 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 105 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 109 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 74 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 41 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 65 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 51 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 53 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 106 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 119 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 27 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 75 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 42 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 33 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 28 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 50 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 52 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 111 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 63 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 115 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 92 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 88 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 93 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 26 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 10 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 120 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 77 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 24 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 87 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 117 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 58 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 25 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 114 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 23 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 49 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 59 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 5 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 31 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 89 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 62 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 43 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 90 to +/- 60.0 deg.\n", "[ Info: angmin and angmax values are 0, widening these values on branch 39 to +/- 60.0 deg.\n", "[ Info: no active generators found at bus 309, updating to bus type from 2 to 1\n", "[ Info: no active generators found at bus 320, updating to bus type from 2 to 1\n", "[ Info: no active generators found at bus 119, updating to bus type from 2 to 1\n", "[ Info: no active generators found at bus 303, updating to bus type from 2 to 1\n", "[ Info: no active generators found at bus 310, updating to bus type from 2 to 1\n", "[ Info: no active generators found at bus 104, updating to bus type from 2 to 1\n", "[ Info: no active generators found at bus 308, updating to bus type from 2 to 1\n", "[ Info: no active generators found at bus 319, updating to bus type from 2 to 1\n", "[ Info: no active generators found at bus 212, updating to bus type from 2 to 1\n", "[ Info: no active generators found at bus 312, updating to bus type from 2 to 1\n", "[ Info: no active generators found at bus 317, updating to bus type from 2 to 1\n", "[ Info: no active generators found at bus 324, updating to bus type from 2 to 1\n", "[ Info: no active generators found at bus 103, updating to bus type from 2 to 1\n", "[ Info: the voltage setpoint on generator 32 does not match the value at bus 118\n", "[ Info: the voltage setpoint on generator 29 does not match the value at bus 118\n", "[ Info: the voltage setpoint on generator 1 does not match the value at bus 101\n", "[ Info: the voltage setpoint on generator 54 does not match the value at bus 201\n", "[ Info: the voltage setpoint on generator 78 does not match the value at bus 221\n", "[ Info: the voltage setpoint on generator 81 does not match the value at bus 222\n", "[ Info: the voltage setpoint on generator 101 does not match the value at bus 307\n", "[ Info: the voltage setpoint on generator 2 does not match the value at bus 101\n", "[ Info: the voltage setpoint on generator 105 does not match the value at bus 310\n", "[ Info: the voltage setpoint on generator 109 does not match the value at bus 313\n", "[ Info: the voltage setpoint on generator 74 does not match the value at bus 215\n", "[ Info: the voltage setpoint on generator 41 does not match the value at bus 121\n", "[ Info: the voltage setpoint on generator 132 does not match the value at bus 315\n", "[ Info: the voltage setpoint on generator 153 does not match the value at bus 322\n", "[ Info: the voltage setpoint on generator 65 does not match the value at bus 213\n", "[ Info: the voltage setpoint on generator 155 does not match the value at bus 322\n", "[ Info: the voltage setpoint on generator 51 does not match the value at bus 123\n", "[ Info: the voltage setpoint on generator 53 does not match the value at bus 123\n", "[ Info: the voltage setpoint on generator 106 does not match the value at bus 312\n", "[ Info: the voltage setpoint on generator 119 does not match the value at bus 313\n", "[ Info: the voltage setpoint on generator 27 does not match the value at bus 115\n", "[ Info: the voltage setpoint on generator 75 does not match the value at bus 215\n", "[ Info: the voltage setpoint on generator 42 does not match the value at bus 122\n", "[ Info: the voltage setpoint on generator 33 does not match the value at bus 118\n", "[ Info: the voltage setpoint on generator 28 does not match the value at bus 116\n", "[ Info: the voltage setpoint on generator 50 does not match the value at bus 123\n", "[ Info: the voltage setpoint on generator 52 does not match the value at bus 123\n", "[ Info: the voltage setpoint on generator 159 does not match the value at bus 324\n", "[ Info: the voltage setpoint on generator 111 does not match the value at bus 313\n", "[ Info: the voltage setpoint on generator 63 does not match the value at bus 207\n", "[ Info: the voltage setpoint on generator 121 does not match the value at bus 313\n", "[ Info: the voltage setpoint on generator 115 does not match the value at bus 313\n", "[ Info: the voltage setpoint on generator 141 does not match the value at bus 319\n", "[ Info: the voltage setpoint on generator 92 does not match the value at bus 301\n", "[ Info: the voltage setpoint on generator 88 does not match the value at bus 223\n", "[ Info: the voltage setpoint on generator 93 does not match the value at bus 301\n", "[ Info: the voltage setpoint on generator 26 does not match the value at bus 115\n", "[ Info: the voltage setpoint on generator 10 does not match the value at bus 102\n", "[ Info: the voltage setpoint on generator 120 does not match the value at bus 313\n", "[ Info: the voltage setpoint on generator 77 does not match the value at bus 218\n", "[ Info: the voltage setpoint on generator 24 does not match the value at bus 114\n", "[ Info: the voltage setpoint on generator 87 does not match the value at bus 223\n", "[ Info: the voltage setpoint on generator 117 does not match the value at bus 313\n", "[ Info: the voltage setpoint on generator 58 does not match the value at bus 202\n", "[ Info: the voltage setpoint on generator 25 does not match the value at bus 115\n", "[ Info: the voltage setpoint on generator 114 does not match the value at bus 313\n", "[ Info: the voltage setpoint on generator 23 does not match the value at bus 113\n", "[ Info: the voltage setpoint on generator 160 does not match the value at bus 324\n", "[ Info: the voltage setpoint on generator 154 does not match the value at bus 322\n", "[ Info: the voltage setpoint on generator 149 does not match the value at bus 321\n", "┌ Info: Constructing System from Power Models\n", "│ data[\"name\"] = \"rts-gmlc\"\n", "└ data[\"source_type\"] = \"pti\"\n", "[ Info: Reading bus data\n", "[ Info: Reading generator data\n", "[ Info: Reading branch data\n", "┌ Warning: Rate 500.0 MW for ATTAR -ATTILA -i_32 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for ASTOR -ATTLEE -i_29 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for ABEL -ADAMS -i_1 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for BARRY -BASOV -i_54 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for CAMUS -CARUSO -i_78 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for CARREL -CARUSO -i_81 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for CLIVE -COMTE -i_101 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for ABEL -ADLER -i_2 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for CURTISS -ATTLEE -i_105 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for CABOT -CAMUS -i_74 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for BACON -BAJER -i_41 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for BEDE -BEETHOVEN -i_65 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for BARKLA -BARLOW -i_51 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for BARLOW -BLOCH -i_53 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for ASTON -ASTOR -i_27 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for CAESAR -CARTER -i_75 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for BAFFIN -BALZAC -i_42 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for ATTILA -AUSTEN -i_33 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for ASTON -AUBREY -i_28 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for BARDEEN -BARRY -i_50 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for BARKLA -BLOCH -i_52 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for BAYLE -BEHRING -i_63 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for CHIFA -CHUHSI -i_92 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for CHASE -CHIFA -i_88 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for CHIFA -CLAY -i_93 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for ASSER -ATTAR -i_26 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for ALDER -ALGER -i_10 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for CALVIN -CARUSO -i_77 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for ARTHUR -AVERY -i_24 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for CHAIN -CHIFA -i_87 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for BARTON -BORDET -i_58 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for ASSER -ASTON -i_25 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for ARTHUR -ATTLEE -i_23 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for BARDEEN -BARLOW -i_49 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for BASOV -BATES -i_59 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for ADAMS -ALBER -i_5 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for ATTAR -ATTILA -i_31 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for CHASE -COBB -i_89 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for BATES -BELL -i_62 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for BAILEY -BALZAC -i_43 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for CHASE -COBB -i_90 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for BACH -BAIN -i_39 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for ATTILA -AUSTEN -i_34 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for BAIN -BANKS -i_44 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for CHUHSI -CLARK -i_94 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for BARTON -BASOV -i_55 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for CECIL -COMTE -i_86 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for ARCHER -AUSTEN -i_17 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 500.0 MW for CLAY -CLIVE -i_99 is larger than the max expected in the range of (min = 134.0, max = 145.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "┌ Warning: Rate 175.0 MW for CABELL -CAESAR -i_71 is larger than the max expected in the range of (min = 47.0, max = 52.0).\n", "└ @ PowerSystems ~/.julia/packages/PowerSystems/61h6O/src/utils/IO/branchdata_checks.jl:148\n", "[ Info: Reading branch data\n", "[ Info: Reading DC Line data\n", "[ Info: Reading storage data\n" ] }, { "output_type": "execute_result", "data": { "text/plain": "System\n======\nSystem Units Base: SYSTEM_BASE\nBase Power: 100.0\nBase Frequency: 60.0\n\nComponents\n==========\nNum components: 539\n\n\u001b[1m9×3 DataFrame\u001b[0m\n\u001b[1m Row \u001b[0m│\u001b[1m ConcreteType \u001b[0m\u001b[1m SuperTypes \u001b[0m\n\u001b[1m \u001b[0m│\u001b[90m String \u001b[0m\u001b[90m String \u001b[0m\n─────┼───────────────────────────────────────────────────────\n 1 │ Arc Topology <: Component <: Infrast…\n 2 │ Area AggregationTopology <: Topology …\n 3 │ Bus Topology <: Component <: Infrast…\n 4 │ FixedAdmittance ElectricLoad <: StaticInjection …\n 5 │ Line ACBranch <: Branch <: Device <: …\n 6 │ LoadZone AggregationTopology <: Topology …\n 7 │ PowerLoad StaticLoad <: ElectricLoad <: St…\n 8 │ TapTransformer ACBranch <: Branch <: Device <: …\n 9 │ ThermalStandard ThermalGen <: Generator <: Stati…\n\u001b[36m 1 column omitted\u001b[0m\n\nTimeSeriesContainer\n===================\nComponents with time series data: 0\nTotal StaticTimeSeries: 0\nTotal Forecasts: 0\n", "text/html": [ "
Base Power: 100.0
\n", "Num components: 539
\n", "9 rows × 3 columns
ConcreteType | SuperTypes | Count | |
---|---|---|---|
String | String | Int64 | |
1 | Arc | Topology <: Component <: InfrastructureSystemsComponent <: InfrastructureSystemsType <: Any | 108 |
2 | Area | AggregationTopology <: Topology <: Component <: InfrastructureSystemsComponent <: InfrastructureSystemsType <: Any | 3 |
3 | Bus | Topology <: Component <: InfrastructureSystemsComponent <: InfrastructureSystemsType <: Any | 73 |
4 | FixedAdmittance | ElectricLoad <: StaticInjection <: Device <: Component <: InfrastructureSystemsComponent <: InfrastructureSystemsType <: Any | 3 |
5 | Line | ACBranch <: Branch <: Device <: Component <: InfrastructureSystemsComponent <: InfrastructureSystemsType <: Any | 105 |
6 | LoadZone | AggregationTopology <: Topology <: Component <: InfrastructureSystemsComponent <: InfrastructureSystemsType <: Any | 21 |
7 | PowerLoad | StaticLoad <: ElectricLoad <: StaticInjection <: Device <: Component <: InfrastructureSystemsComponent <: InfrastructureSystemsType <: Any | 51 |
8 | TapTransformer | ACBranch <: Branch <: Device <: Component <: InfrastructureSystemsComponent <: InfrastructureSystemsType <: Any | 15 |
9 | ThermalStandard | ThermalGen <: Generator <: StaticInjection <: Device <: Component <: InfrastructureSystemsComponent <: InfrastructureSystemsType <: Any | 160 |
Components with time series data: 0
\n", "Total StaticTimeSeries: 0
\n", "Total Forecasts: 0
\n", "Resolution: 0 seconds
\n" ] }, "metadata": {}, "execution_count": 3 } ], "cell_type": "code", "source": [ "sys = System(joinpath(base_dir, \"data\", \"psse_raw\", \"RTS-GMLC.RAW\"));\n", "\n", "sys" ], "metadata": {}, "execution_count": 3 }, { "cell_type": "markdown", "source": [ "---\n", "\n", "*This notebook was generated using [Literate.jl](https://github.com/fredrikekre/Literate.jl).*" ], "metadata": {} } ], "nbformat_minor": 3, "metadata": { "language_info": { "file_extension": ".jl", "mimetype": "application/julia", "name": "julia", "version": "1.6.0" }, "kernelspec": { "name": "julia-1.6", "display_name": "Julia 1.6.0", "language": "julia" } }, "nbformat": 4 }