On/Off switch This IPSO object should be used with an On/Off switch to report the state of the switch. 3342 urn:oma:lwm2m:ext:3342:1.1 1.0 1.1 Multiple Optional Digital Input State R Single Mandatory Boolean The current state of a digital input. Digital Input Counter R Single Optional Integer The cumulative value of active state detected. On time RW Single Optional Integer s The time in seconds that the device has been on. Writing a value of 0 resets the counter. Off Time RW Single Optional Integer s The time in seconds in the off state. Writing a value of 0 resets the counter. Application Type RW Single Optional String The application type of the sensor or actuator as a string depending on the use case. Timestamp R Single Optional Time The timestamp of when the measurement was performed. Fractional Timestamp R Single Optional Float 0..1 s Fractional part of the timestamp when sub-second precision is used (e.g., 0.23 for 230 ms).