Filling level The uCIFI filling level sensor measures how full and/or how empty a container (e.g. waste, fuel) is and reports it either in percentage or in centimeters. The filling level sensor may be complemented with a temperature sensor to compose a waste filling sensor that can also identify waste container fire. 3435 urn:oma:lwm2m:ext:3435 1.0 1.0 Multiple Optional Container height RW Single Optional Integer cm Height of the container. Actual filling percentage R Single Mandatory Float /100 Percentage of container filled with content. Actual filling level R Single Optional Integer cm Height of content in the container. High threshold RW Single Optional Float /100 Threshold above which the container is considered full. Container full R Single Mandatory Boolean Set to True if the actual filling percentage is above the high threshold. Low threshold RW Single Optional Float /100 Threshold below which the container is considered empty. Container empty R Single Mandatory Boolean Set to True if the actual filling percentage is below the low threshold. Average filling speed R Single Optional Float /100 Average percentage filled per day. Average filling speed reset E Single Optional Reset average filling speed. Forecast full date R Single Optional Time Next date at which the container should reach the high threshold. Forecast empty date R Single Optional Time Next date at which the container should reach the low threshold. Container out of location R Single Optional Boolean Set to True if the container is not at the location where it should be. Container out of position R Single Optional Boolean Set to True if the container is not in correct upright position.