images/shenzen_neo/nas-pd02z.png Fix parameters for temperature model, based on user feedback https://github.com/OpenZWave/open-zwave/issues/1866 Add Product Pic Entry Adapt the sensitivity of the motion detection. This parameter can be determined how long the associated devices should stay ON status. For instance, this parameter is set to 30(second), the PIR detector will send a BASIC_SET Command to an associated device with value basic set level if PIR detector is triggered and the associated device will be turned on 30(second) before it is turned off. This Parameter value must be large than Parameter 6#. If user set this parameter to default by Configure CC, the parameter #6 will be set to default value. Available Settings:5 to 600(second). Basic Set Command will be sent, on the associated devices (group 2), where contains a value when PIR detector is triggered, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be. This Parameter is used to some associated devices. Available Settings: 0, 1 to 99 or 255. Enable the motion detection (PIR) function. This parameter does not effect the luminance reporting. Define the illumination level value which determines when the 'Illumination switch ON function' is activated. If the illumination level falls below this value and a person moves across or within the detected area, the motion sensor will switch on the associated device (group 2). 0 to 1000(Lux). Period after motion detection in which the sensor is insensitive for new motion detection. This value must be less than the 'Motion detection ON time'. Available Settings: 1 to 8(s). Determine the time between illumination reports, even when value has not changed. NOTE: This Value Must Be less than Wakeup Interval Time. Available Settings: 60 ~ 36000(second). Enable the function to switch on a associated device (group 2) once motion has been detected and the illumination level will be less than the value specified in 'Illumination switch ON level'. This parameter defines by how much Lux Level must change, in lux, to be reported to the main controller. This parameter is configured the value that differential between current measured and previous report value. If the differential value larger than the settings, device will report this measured temperature value to nodes associated in lifeline. This parameter can enabled or disable the PIR led blinking function. The motion detected event can be sent multiple times/only once until device report motion cleared event. This parameter defines the calibrated scale for ambient light intensity.