Use Goal Current(102) to set a desired current when the [Operating Mode(11)] is **Torque Control Mode**. Also, the Goal Current(102) can be used to set a limit to current in Current-based Position Control Mode. Note that the Goal Current(102) can not be set larger than the [Current Limit(38)].