Attribute details
|
|
Name
|
Name of the calibration attribute.
|
|
Short description
|
Brief description of the calibration attribute.
|
|
Criticality
|
Criticality level that indicates how important the calibration attribute is.
|
|
Service frequency
|
Frequency at which you must perform the calibration.
|
|
Category
|
Type of calibration.**Note:** The Enterprise Asset Management application includes default calibration categories such as Electrical, Flow, Humidity, and Pressure. You can create additional calibration categories for any calibrations that do not fall under the default categories. For detailed instructions, see [Create a calibration category for your enterprise asset calibrations](https://raw.githubusercontent.com/ServiceNow/ServiceNowDocs/australia/markdown/australia/it-asset-management/enterprise-asset-management/create-eam-calibration-categories.md).
|
|
Active
|
Option that indicates if the calibration attribute is active.
|
|
Order
|
Order in which the calibration attribute applies to the enterprise asset. If your enterprise asset contains more than one calibration attribute, the attribute with the lowest numerical value applies to the asset first.**Important:** You must use a unique numerical value for each calibration attribute.
|
|
Calibration properties
|
|
Value type
|
Method by which you want to measure tolerance conformance. Select one of the following options:- **Accuracy % full scale**: Fixed percentage of accuracy that your calibration measurements must fall within at any point within the enterprise asset's full measurement range. The corresponding tolerance limits remain the same at every point within the measurement range. For example, if a measurement range is 100 units and the accuracy percentage is set to ±1%, the tolerance limits are ±1 unit at every point within the measurement range.
- **Accuracy % point**: Fixed percentage of accuracy that your calibration measurements must fall within at a specific point within the enterprise asset's full measurement range. The corresponding tolerance limits increase or decrease proportionally based on the value of the point that you are comparing your calibration measurement against. For example, if your accuracy percentage is set to ±1% and you want to compare your calibration measurement against a point that has a value of 50 units, the tolerance limits for this specific point are ±0.5 units. If you want to compare your calibration measurement against a point that has a value of 60 units, the tolerance limits increase to ±0.6 units.
- **Range**: Measurement range that your calibration measurements must fall within. The corresponding tolerance limits are based on the lowest and highest acceptable point values within the range.
- **Less than**: Value within the enterprise asset's full measurement range that your calibration measurements must fall below. The corresponding tolerance limit is based on the highest acceptable point value within the range.
- **Greater than**: Value within the enterprise asset's full measurement range that your calibration measurements must lie above. The corresponding tolerance limit is based on the lowest acceptable point value within the range.
- **True/false**: Option to assess any qualitative elements of the calibration.
|
|
Scale
|
Full measurement range that you're measuring tolerance conformance against.**Note:** This field appears only if you set the **Value type** field to **Accuracy % full scale**.
|
|
Unit
|
Unit of measurement that you're using to measure tolerance conformance.**Note:** This field appears only if you set the **Value type** field to one of the following options:
- **Accuracy % full scale**
- **Accuracy % point**
- **Range**
- **Less than**
- **Greater than**
|
|
Accuracy \(%\)
|
Percentage of accuracy that your calibration measurements must fall within.**Note:** This field appears only if you set the **Value type** field to either **Accuracy % full scale** or **Accuracy % point**.
|
|
Resolution
|
Smallest distinguishable change in value that you can detect and measure. The higher the resolution is, the more specific the change in value is.**Note:** This field appears only if you set the **Value type** field to one of the following options:
- **Accuracy % full scale**
- **Accuracy % point**
|
|
Quality standard
|
|
Quality standard
|
Set of requirements and guidelines that you must follow when performing the calibrations.**Note:** You can create quality standards manually in the Admin center view of the Enterprise Asset Workspace. See [Create a quality standard for your enterprise asset calibrations](https://raw.githubusercontent.com/ServiceNow/ServiceNowDocs/australia/markdown/australia/it-asset-management/enterprise-asset-management/create-eam-calibration-quality-standard.md) for detailed instructions.
|
|
Instrument
|
|
Instrument model
|
Model of the instrument that you must use to perform the calibrations.
|
|
Instruction
|
General instructions or instrument settings that you must follow when performing the calibrations.
|