--- title: Configure event collection from OBM description: Configure the Operation Bridge Manager \(OBM\), also known as OMi v2, connector instance to receive alerts from the OBM server. The OBM connector script OBM v2 will be available after installing the Event Management Connectors app. locale: en-US canonical_url: https://www.servicenow.com/docs/r/australia/it-operations-management/event-management/configure-obm-connector.html release: australia product: Event Management classification: event-management topic_type: task last_updated: "2026-03-12" reading_time_minutes: 3 breadcrumb: [Configure a pull connector, Configure Event Management connectors, Event Management Integrations, Configure, Event Management, ITOM AIOps, IT Operations Management] --- # Configure event collection from OBM Configure the Operation Bridge Manager \(OBM\), also known as OMi v2, connector instance to receive alerts from the OBM server. The OBM connector script OBM v2 will be available after installing the Event Management Connectors app. ## Before you begin Role required: evt\_mgmt\_admin Supported versions: 10.01, 10.10, 10.11, 10.12, 10.60, 10.61, and 11.01. ## About this task Starting from the Xanadu release, the OOTB \(Out-Of-The-Box\) event rules provided with the connector, which you have not previously used \(i.e., neither activated, deactivated, nor modified\), will now have the **Apply additional matching rules** check box set to true. Previously, this check box was disabled. This change allows you to execute more event rules or automation using the same filter conditions for the events. **Note:** This feature applies only to active event rules. ## Procedure 1. Navigate to **All** > **Event Management** > **Event Connectors \(Pull\)** > **Connector Instances**. 2. Click **New** and create a connector instance with the following details:
| Field | Value |
|---|---|
| Name | Descriptive name for the OBM connector. |
| Description | Description for the use of the OBM event collection instance. |
| Host IP | Specify the OBM IP address. |
| Credential | Select the required credentials from the list or click **New** and create the required credentials. If you create the credentials, save them using a unique and recognizable name, for example OBMOPS. |
| Event collection last run time | The last run time value is automatically updated. |
| Last event collection status | The last run time value is automatically updated. |
| Event collection schedule \(seconds\) | Frequency in seconds that the system checks for new events from OBM. The default value is 120 seconds. |
| Last error message | The last error message is automatically updated |
| Connector Definition | Select **OBM V2**.**Note:** This script will be available after installing the Event Management connector scoped app. |
| MID Servers \(MID Server for Connectors section\) | Specify the MID Server to run the OBM connector instance. You can configure several MID Servers. If the first server is down, the next MID Server If that MID Server is not available, the next is selected, and so on. MID Servers are sorted according to the order that their details were entered into the MID Server for Connectors section. If no MID Server is specified, an available MID Server that has a matching IP range is used. |