title: Splunk UDP integration configuration fields
description: Description of the fields on the Splunk UDP integration configuration forms for Health Log Analytics.
locale: en-US
canonical_url: https://www.servicenow.com/docs/r/australia/it-operations-management/health-log-analytics/il-connector-hla-splunkudp-fields.html
release: australia
product: Health Log Analytics
classification: health-log-analytics
topic_type: reference
last_updated: "2026-03-12"
reading_time_minutes: 2
keywords: [Splunk UDP, data input, integration, configuration, field, description, ServiceNow, Health Log Analytics, HLA]
breadcrumb: [Integration configuration fields, Health Log Analytics reference, Health Log Analytics, ITOM AIOps, IT Operations Management]
---
# Splunk UDP integration configuration fields
Description of the fields on the Splunk UDP integration configuration forms for Health Log Analytics.
For the Splunk UDP integration setup procedure, see [Set up a Splunk UDP integration for Health Log Analytics](https://raw.githubusercontent.com/ServiceNow/ServiceNowDocs/australia/markdown/australia/it-operations-management/health-log-analytics/il-connector-hla-splunkudp.md).
|
Field
|
Description
|
|---|
|
Integration Name
|
Unique name of this integration. For example: My Splunk UDP integration. This field is required.**Note:** When you fill in this field, the generic name displayed on the form adjusts automatically to match the name you entered.
|
|
MID server name
|
MID Server to which log data from Splunk is pulled. This field is required.**Note:**
- You can select only MID Servers that support basic authentication. MID Servers that support mTLS are not listed.
- The default maximum number of data inputs streaming logs to a single MID Server is 10. You can modify this number in the MID Server properties.
- If log ingestion is not enabled for the selected MID Server, Health Log Analytics enables it automatically.
|
|
Port
|
The port for the MID Server. This field is required. **Note:** Make sure that your organization’s security team opens the selected port on the MID Server.
|
|
Description
|
Option to add a brief description of the integration to help identify it.
|
|
Transport
|
The protocol used for streaming log messages to your ServiceNow instance: UDP. This field is read-only.
|
|
Field
|
Description
|
|---|
|
Lookup hostnames
|
Option to perform DNS lookup to resolve IPs to hostnames. The default value is false.
|
|
Sub sample receive ratio
|
The ratio of logs to receive. The default value is -1: no logs are received.For example: If you want one out of every five logs to be received, change the value to 5.
|
|
Character encoding
|
The character encoding for this data input. The default value is UTF-8. This field is read-only.
|
|
Drop if queue is full
|
Option to discard logs if there is a load on the MID Server.
|
|
Sub sample drop ratio
|
The ratio of logs to drop. The default value is -1: no logs are dropped.For example: If you want one out of every five logs to be dropped, change the value to 5.
|
|
Max length in bytes
|
The maximum length of log messages in bytes. The default value is 32766.
|
|
Default timezone
|
The time zone of events that the system will use if a log does not specify the time zone.By default, the system uses GMT in such cases, but you can specify a different time zone.
|