|
Manufacturer
|
Name of the network asset's manufacturer. Select the search icon \(\[Omitted image "search.png"\] Alt text: Search icon.\) and select a manufacturer code. To learn more, see [Create manufacturer and vendor codes](https://raw.githubusercontent.com/ServiceNow/ServiceNowDocs/australia/markdown/australia/telecom-network-inventory/telecommunications-network-inventory/add-company-designate-manufacturer-tni.md).
|
|
Model number
|
Manufacturer's model number for this network asset.
|
|
Orientation
|
Physical orientation of the slots in this network asset:
- **--None--**
No specific physical slot orientation.
- **Horizontal**
Horizontal slot orientation.
- **Vertical**
Vertical slot orientation.
|
|
Unit position
|
Unit position of this network asset.
|
|
Network Domain
|
Domain of ownership and responsibility for this network asset or connection. Select one of the following options:- **Mobility**
Network asset that is associated with the mobility equipment domain.
- **Telco**
Network asset that is associated with the Telco equipment domain.
- **Core**
Network asset that is associated with the core equipment domain.
|
|
Units occupied
|
Total number of equipment holder units, both occupied and available, in this network asset.
|
|
Units in use
|
Number of equipment holder units that are in use in this network asset.
|
|
Units available
|
Number of equipment holder units that are available for use in this network asset.
|
|
Comments
|
Free form text that is used to comment on a network asset. For example, `Duty tech is Rahul Dev`.
|
|
Allotted Electric Power
|
Maximum power allotted to the asset.**Note:**
- To maintain the power capacity of the rack/cabinet, it’s essential to incorporate a minimum value of 10 Watts.
- By default, the value is converted to Kilowatts \(KW\), in the capacity metric and following is the conversion formula
- Watts \(W\) - <power-in-watts> / 1000
- Megawatts \(MW\) - 1000 \* <power-in-mega-watts>
- Horsepower \(HP\) - 0.746 \* <power-in-horsepower>
|
|
Allotted Electric Power unit
|
Units in which the allotted electric power of the asset is measured. Select any one of the following units.- Watts \(W\)
- Kilowatts \(KW\)
- Megawatts \(MW\)
- Horsepower \(HP\)
|
|
Unit of Measure System
|
Measurement type based on which the **Max weight capacity unit** is fetched. Select any one of the following measurement types.- Metric
- US Imperial
|
|
Max weight capacity
|
Maximum capacity of assets.**Note:** By default, the value is converted to Pounds \(lbs\), in the capacity metric and following is the conversion formula
- Ounces: <weight-in-ounces> / 16
- Grams: <weight-in-grams> / 453.59
- Kilograms: 2.204 \* <weight-in-kilograms>
|
|
Max weight capacity unit
|
Unit in which weight of the asset is measured. Select any one of the following.- Grams \(g\)
**Note:** This field is only accessible when the Metric system is used for unit of measurement.
- Kilograms \(kg\)
**Note:** This field is only accessible when the Metric system is used for unit of measurement.
- Ounces \(oz\)
**Note:** This field is only accessible when the US Imperial system is used for unit of measurement.
- Pounds \(lbs\)
**Note:** This field is only accessible when the US Imperial system is used for unit of measurement.
|