--- uw_version: "3.0" deal_id: "uw_2026_dc7q4m1" deal_name: "Mesa Gateway Data Center — Mesa, AZ" created: "2026-09-09T08:00:00Z" last_modified: "2026-09-09T11:00:00Z" property_address: "6200 S Basalt Ridge Rd" city: "Mesa" state: "AZ" zip: "85212" asset_class: "data_center" loan_type: "permanent" scenario: "stabilized_acquisition" status: "in_progress" deal_stage: "full_underwrite" recommendation: "pending" quick_metrics: purchase_price: 160000000 loan_amount: 96000000 noi_underwritten: 11200000 dscr: 1.579 ltv: 0.6 debt_yield: 0.1167 cap_rate: 0.07 irr_projected: 0.135 equity_required: 69000000 flags: - "phase_2_pre_lease_rent_commencement_gap" blocking_flags: [] tier: "analyst" institution_config_id: null created_by: "wizard" source_documents: - "mesa_gateway_rent_roll_aug2026.xlsx" - "mesa_gateway_t12_2025.pdf" - "mesa_gateway_arroyo_power_capacity_letter_2026.pdf" - "mesa_gateway_appraisal_2026.pdf" --- > Synthetic example: every name, party and figure in this record is fictional. # Mesa Gateway Data Center — Mesa, AZ > **Deal ID:** uw_2026_dc7q4m1 | **Scenario:** Stabilized Acquisition | **Status:** In Progress > **10.0 MW Commissioned / 12.5 MW Planned** | **11.0 MW Contracted** | **PUE 1.25** | **$160,000,000 Purchase** | **$16,000/kW** | **7.00% Cap Rate (in-place)** This is the standard's builtin data-center example (RFC 0080). Its three `dc_*` sections state capacity in **kilowatts**, PUE, redundancy, power billing, and rent per kW-month alongside the standard real-estate inputs. The record carries two documented review conditions: 1,000 kW of phase 2 is pre-leased ahead of commissioning (`CC-DC-04`), and the in-place rent runs 20% under the comp set, a 25% mark-to-market (`CC-DC-07`). Both appear as warnings in the stored validation result and runtime output. --- ## Deal Context {#deal_context} Mesa Gateway is a 10 MW (critical IT) wholesale data center in the Elliot Road corridor, 100% contracted to two tenants on power-metered leases, with a permitted 2.5 MW phase 2 already pre-leased to the anchor. Thesis: acquire a modern N+1 facility with a secured 15 MW utility feed at $16,000/kW — well below the cost of new powered capacity in a market where the utility queue, not land, is the constraint. ```json uw:section=deal_context source=manual ts=2026-09-09T08:20:00Z v=1 confidence=high { "_meta": { "section": "deal_context", "provenance": { "source": "manual", "actor": "analyst", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T08:20:00Z", "notes": null }, "quality": { "confidence": "high", "human_review_required": false, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "_notes": "Utility feed is 15 MW under an executed Arroyo Power capacity agreement, which covers the 12.5 MW build-out at design PUE. Phase 2 (2.5 MW) is permitted; 1 MW of it is pre-leased to the anchor with rent commencing on delivery.", "deal_summary": "10 MW commissioned wholesale data center in Mesa, 100% contracted to two tenants under metered pass-through power, with a permitted 2.5 MW phase 2 of which 1 MW is pre-leased.", "investment_thesis": "Secured utility capacity is the scarce asset in the East Valley. Buying commissioned, contracted megawatts at $16,000/kW, with an expansion phase already permitted and partly pre-leased, captures the utility-queue premium without development risk.", "value_creation_strategy": "Deliver phase 2 into the pre-lease, mark the anchor's 2029 renewal to a market that is 25% above the in-place rate, and hold the interconnection and services lines as they scale with density.", "hold_strategy": "core_plus_hold", "exit_strategy_description": "Sell into the institutional bid for stabilized wholesale capacity at year 5-7, or refinance once phase 2 is delivered and the anchor renews at market.", "deal_goal": "13-14% levered IRR with contracted cash flow and a permitted expansion." } ``` --- ## Property {#property} `rentable_square_feet` explicitly states rentable building area as a secondary size; it does not state the building footprint or infer area from power. White space (`raised_floor_sf`) is separately stated in the capacity section. Commissioned critical IT kW remains the primary size for this data center. No area measurement standard is asserted here. ```json uw:section=property source=manual ts=2026-09-09T08:40:00Z v=1 confidence=high { "_meta": { "section": "property", "provenance": { "source": "manual", "actor": "analyst", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T08:40:00Z", "notes": null }, "quality": { "confidence": "high", "human_review_required": false, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "rentable_square_feet": 180000, "year_built": 2021, "building_class": "A", "stories": 1, "site_acres": 22.4, "parking_spaces": 120, "parking_type": "surface", "condition": "excellent", "occupancy_pct": 1, "submarket": "Elliot Road corridor / East Valley", "critical_it_load_kw": 10000, "_notes": " Primary size is an identity of the stated dc_capacity.critical_it_load_kw field." } ``` --- ## Rent Roll {#rent_roll} Two in-place tenants on wholesale leases, rent quoted per kW-month and carried here as annual base rent over the white space each occupies. The 1,000 kW phase-2 pre-lease is **not** in the roll — rent commences on delivery — and appears only in `dc_capacity.contracted_it_load_kw`. ```json uw:section=rent_roll source=manual ts=2026-09-09T09:10:00Z v=1 confidence=high { "_meta": { "section": "rent_roll", "provenance": { "source": "manual", "resolution": "user_input", "actor": "analyst", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T09:10:00Z", "notes": null }, "quality": { "confidence": "high", "human_review_required": false, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "_notes": "Both leases are metered pass-through on power. Anchor rolls 2029-12-31; in-place at $150/kW-mo vs ~$187.50 market. Phase-2 pre-lease (1,000 kW, $150/kW-mo) commences on delivery, targeted 2027-07-01.", "as_of_date": "2026-08-01", "total_rentable_sf": 60000, "occupied_sf": 60000, "vacant_sf": 0, "occupancy_pct": 1, "weighted_avg_rent_psf": 300, "tenants": [ { "tenant_id": "T-A", "tenant_name": "Helios Cloud Services", "suite": "Hall 1-2", "leased_sf": 36000, "annual_base_rent": 10800000, "rent_psf": 300, "lease_start": "2022-01-01", "lease_expiration": "2029-12-31", "lease_type": "NNN", "tenant_credit": "investment_grade", "anchor_tenant": true }, { "tenant_id": "T-B", "tenant_name": "Meridian Colo Partners", "suite": "Hall 3", "leased_sf": 24000, "annual_base_rent": 7200000, "rent_psf": 300, "lease_start": "2023-04-01", "lease_expiration": "2033-03-31", "lease_type": "NNN", "tenant_credit": "non_investment_grade", "anchor_tenant": false } ] } ``` --- ## NOI Model {#noi_model} Year-1 underwritten on the 10,000 kW in place. Power is a pass-through: the $8.76M utility bill on the commissioned load at design PUE is recovered under `expense_reimbursements` and expensed under `utilities`, so it nets to zero at NOI. ```json uw:section=noi_model source=system/calculations.ts ts=2026-09-09T10:30:00Z v=1 confidence=high { "_meta": { "section": "noi_model", "provenance": { "source": "system/calculations.ts", "actor": "system", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T10:30:00Z", "notes": null }, "quality": { "confidence": "high", "human_review_required": false, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "_notes": "Base rent = 10,000 kW x $150 x 12. Reimbursements = 10,000 kW x 1.25 PUE x 8,760 h x $0.08/kWh, matched by utilities expense. Other income = interconnection ($660,000) + remote hands and services ($264,000).", "income": { "base_rent": 18000000, "vacancy_credit_loss": 0, "expense_reimbursements": 8760000, "other_income": 924000, "effective_gross_income": 27684000 }, "expenses": { "property_taxes": 2400000, "insurance": 520000, "cam": 2023480, "utilities": 8760000, "repairs_maintenance": 1650000, "management_fee": 830520, "general_admin": 300000, "total_operating_expenses": 16484000 }, "net_operating_income": 11200000, "noi_per_sf": 62.22 } ``` --- ## Operating Statement (T-12) {#operating_statement} Trailing-twelve summary reconciled to the NOI model — same revenue, expense and NOI totals, with power billed through at cost on both sides. The line-item detail lives in the source statement. ```json uw:section=operating_statement source=system/extractor ts=2026-09-09T11:00:00Z v=1 confidence=medium { "_meta": { "section": "operating_statement", "provenance": { "source": "system/extractor", "resolution": "ai_extracted", "actor": "analyst", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T11:00:00Z", "notes": "T-12 summary reconciled to the NOI model; line detail retained in the source statement." }, "quality": { "confidence": "medium", "human_review_required": false, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "period": "t12", "period_end": "2026-06-30", "statement_basis": "accrual", "income": { "total_revenue": 27684000 }, "expenses": { "total_operating_expenses": 16484000 }, "net_operating_income": 11200000, "reconciles_to_noi_model": true } ``` --- ## Debt Structure {#debt_structure} ```json uw:section=debt_structure source=manual ts=2026-09-09T10:45:00Z v=1 confidence=high { "_meta": { "section": "debt_structure", "provenance": { "source": "manual", "actor": "analyst", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T10:45:00Z", "notes": null }, "quality": { "confidence": "high", "human_review_required": false, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "_notes": "Fixed-rate permanent debt at 60% LTV, sized inside a 1.58x DSCR / 11.7% debt yield. Lender underwrote the in-place 10 MW only; phase 2 is unencumbered upside.", "loan_type": "permanent", "lender_type": "life_co", "loan_amount": 96000000, "ltv": 0.6, "ltc": 0.58, "interest_rate_type": "fixed", "all_in_rate_at_close": 0.0625, "term_months": 120, "amortization_months": 360, "amortization": "30yr_amortizing", "io_months": 0, "annual_debt_service": 7093062, "underwritten_noi": 11200000, "dscr": 1.579, "debt_yield": 0.1167, "recourse": "non_recourse_with_carve_outs", "prepayment": "yield_maintenance" } ``` --- ## Sources & Uses {#sources_uses} ```json uw:section=sources_uses source=system/calculations.ts ts=2026-09-09T10:50:00Z v=1 confidence=high { "_meta": { "section": "sources_uses", "provenance": { "source": "system/calculations.ts", "actor": "system", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T10:50:00Z", "notes": null }, "quality": { "confidence": "high", "human_review_required": false, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "sources": { "loan_amount": 96000000, "sponsor_equity": 69000000, "total": 165000000 }, "uses": { "purchase_price": 160000000, "closing_costs": 3200000, "ti_lc_reserve": 1800000, "total": 165000000 }, "total_sources": 165000000, "total_uses": 165000000, "equity_metrics": { "equity_total": 69000000 }, "_notes": " equity_total equals the single stated sponsor-equity source (identity of stated fields)." } ``` --- ## Valuation {#valuation} `price_per_sf` uses the explicitly stated `property.rentable_square_feet` as a secondary price comparison. The primary pricing denominator remains commissioned critical IT kW, through the builtin `price_per_commissioned_kw` calculation. No conversion between kW, rentable area and raised-floor area is implied. RFC 0125 binds the SF figure to data-center dictionary verification. ```json uw:section=valuation source=manual ts=2026-09-09T11:00:00Z v=1 confidence=high { "_meta": { "section": "valuation", "provenance": { "source": "manual", "resolution": "user_input", "actor": "analyst", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T11:00:00Z", "notes": null }, "quality": { "confidence": "high", "human_review_required": false, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "purchase_price": 160000000, "appraised_value": 162500000, "underwritten_value": 160000000, "going_in_cap_rate": 0.07, "exit_cap_rate_assumption": 0.0725, "valuation_method": "income_capitalization", "price_per_sf": 888.89, "stabilized_value_estimate": 172000000, "cap_rate": 0.07, "ltv": 0.6, "ltc": 0.581818, "dscr": 1.579, "debt_yield": 0.116667, "cash_on_cash": 0.059521, "utilization": 1.1, "commissioned_share": 0.8, "facility_load_kw": 12500, "annual_facility_kwh": 82676880, "annual_power_cost": 0, "power_cost_per_kw_month": 0, "annual_rent_revenue": 19800000, "blended_revenue_per_kw_month": 157, "mark_to_market": 0.25, "price_per_commissioned_kw": 16000, "noi_per_commissioned_kw": 1120, "price_per_kw": 16000, "noi_per_kw": 1120, "loan_per_kw": 9600, "_notes": " RFC 0080 starter metrics are deterministic outputs of the stated inputs; no default or cascade was used." } ``` ## Preliminary Sizing Loan sizing against the three standard constraints. The governing test is LTV; the proposed loan of $96,000,000 fits inside it. ```json uw:section=preliminary_sizing source=manual ts=2026-09-09T10:40:00Z v=1 confidence=medium { "_meta": { "section": "preliminary_sizing", "provenance": { "source": "manual", "actor": "analyst", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T10:40:00Z", "notes": null }, "quality": { "confidence": "medium", "human_review_required": false, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "sizing_basis": { "noi_underwritten": 11200000, "value_basis": 160000000, "annual_debt_constant": 0.0739 }, "constraints": [ { "test": "max_ltv", "limit": 0.75, "max_loan": 120000000 }, { "test": "min_dscr", "limit": 1.25, "max_loan": 121244925 }, { "test": "min_debt_yield", "limit": 0.09, "max_loan": 124444444 } ], "max_supportable_loan": 120000000, "governing_constraint": "ltv", "proposed_loan": 96000000, "proposed_within_constraints": true, "cushion": 24000000 } ``` ## Borrower / Sponsor {#borrower_sponsor} Mesa Gateway Holdings LLC, a single-asset borrower controlled by one sponsor entity. Principals only: sponsor financial statements are requested for the diligence period, so no net-worth or liquidity figure is stated yet. ```json uw:section=borrower_sponsor source=manual ts=2026-09-09T11:00:00Z v=1 confidence=medium { "_meta": { "section": "borrower_sponsor", "provenance": { "source": "manual", "actor": "analyst", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T11:00:00Z", "notes": "Principals only; sponsor PFS and liquidity statements requested for the DD period." }, "quality": { "confidence": "medium", "human_review_required": true, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "principals": [ { "name": "Sonoran Digital Infrastructure Partners LP", "role": "sponsor", "ownership_pct": 1, "is_guarantor": true, "is_key_man": false, "pfs_received": false, "tax_returns_received": false, "figures_verified": false } ], "entity": { "name": "Mesa Gateway Holdings LLC", "type": "llc", "state": "DE" } } ``` --- ## Market Analysis East Valley wholesale fundamentals as of 2026-08. Rent is quoted per kW-month; the comp set is carried in `dc_revenue.market_rent_per_kw_month`. ```json uw:section=market_analysis source=manual ts=2026-09-09T09:30:00Z v=1 confidence=medium { "_meta": { "section": "market_analysis", "provenance": { "source": "manual", "actor": "analyst", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T09:30:00Z", "notes": "Broker survey and published capacity reports; refresh before credit committee." }, "quality": { "confidence": "medium", "human_review_required": false, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "market": "Phoenix Metro", "submarket": "Mesa / East Valley", "data_as_of": "2026-08-01", "vacancy": { "current_rate": 0.03, "trend": "stable" }, "rents": { "yoy_growth_pct": 0.08, "trend": "rising" }, "cap_rates": { "range_low": 0.065, "range_high": 0.0725, "subject_going_in": 0.07 }, "supply": { "note": "Announced capacity is large but utility-gated; delivered megawatts remain scarce through 2028." } } ``` --- ## Capacity & Topology {#dc_capacity} Every figure is in **kW** — capacity is quoted in MW and rent in $/kW-month, and one unit throughout is what prevents a x1000 error. Contracted load (11,000 kW) exceeds commissioned load (10,000 kW) because 1,000 kW of phase 2 is pre-leased; that is `CC-DC-04`, a schedule question and not a defect. ```json uw:section=dc_capacity source=manual ts=2026-09-09T09:00:00Z v=1 confidence=high { "_meta": { "section": "dc_capacity", "provenance": { "source": "manual", "actor": "analyst", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T09:00:00Z", "notes": null }, "quality": { "confidence": "high", "human_review_required": false, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "_notes": "Commissioned 10 MW in three halls; permitted phase 2 adds 2.5 MW. Utility feed 15 MW per the Arroyo Power capacity agreement — covers full build-out at design PUE (12,500 kW x 1.25 = 15,625 kW is the future check, not today's). Measured PUE 1.32 on the T-12, within 15% of the 1.25 design.", "critical_it_load_kw": 10000, "planned_it_load_kw": 12500, "contracted_it_load_kw": 11000, "utility_feed_kw": 15000, "design_pue": 1.25, "measured_pue": 1.32, "redundancy": "n_plus_1", "raised_floor_sf": 60000, "design_density_kw_per_rack": 12.5 } ``` ## Power Economics {#dc_power} Metered pass-through: tenants pay their own metered power at cost, so the landlord earns no power margin, `power_margin` is null, and the landlord's power cost is zero (RFC 0103). No metered facility total is carried; the operator's stated average draw of 65% of contracted load, at the trailing measured PUE of 1.32, gives the facility's annual energy. Full draw is never assumed. ```json uw:section=dc_power source=manual ts=2026-09-09T09:05:00Z v=1 confidence=high { "_meta": { "section": "dc_power", "provenance": { "source": "manual", "actor": "analyst", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T09:05:00Z", "notes": null }, "quality": { "confidence": "high", "human_review_required": false, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "utility_rate_per_kwh": 0.08, "billing": "metered_pass_through", "power_margin": null, "stated_annual_power_cost": null, "metered_annual_kwh": null, "draw_factor": 0.65 } ``` ## Revenue {#dc_revenue} Weighted-average contracted rent of $150/kW-month on the 11,000 kW contracted, against a $187.50 comp set — a 25% mark-to-market (market above in-place: upside at the anchor's 2029 roll), which is what fires `CC-DC-07`. ```json uw:section=dc_revenue source=manual ts=2026-09-09T09:15:00Z v=1 confidence=high { "_meta": { "section": "dc_revenue", "provenance": { "source": "manual", "actor": "analyst", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T09:15:00Z", "notes": null }, "quality": { "confidence": "high", "human_review_required": false, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "lease_type": "wholesale_turnkey", "rent_per_kw_month": 150, "interconnection_revenue_annual": 660000, "services_revenue_annual": 264000, "market_rent_per_kw_month": 187.5 } ``` --- ## Validation {#validation} Financial-validity engine run over the sections above. ```json uw:section=validation source=system/financialValidityChecker ts=2026-09-09T11:00:00Z v=1 confidence=high { "_meta": { "section": "validation", "provenance": { "source": "system/financialValidityChecker", "actor": "system", "agent_id": null, "agent_version": null, "timestamp": "2026-09-09T11:00:00Z", "notes": null }, "quality": { "confidence": "high", "human_review_required": false, "flags": [], "partial": false, "provisional": false }, "lifecycle": { "revision": 1, "superseded": false } }, "overall_status": "warnings", "financial_validity": [], "completeness": [], "cross_section_consistency": [ { "flag_id": "CC-DC-04", "sections_involved": ["dc_capacity"], "description": "Contracted load exceeds commissioned load — pre-leased phases; confirm the delivery schedule and any rent-commencement gaps.", "severity": "warning", "field_a": { "section": "dc_capacity", "field": "contracted_it_load_kw", "value": 11000 }, "field_b": { "section": "dc_capacity", "field": "critical_it_load_kw", "value": 10000 }, "variance": null }, { "flag_id": "CC-DC-07", "sections_involved": ["dc_revenue"], "description": "Contracted rent more than 15% below market — verify the comp set or the lease vintage.", "severity": "warning", "field_a": { "section": "dc_revenue", "field": "rent_per_kw_month", "value": 150 }, "field_b": { "section": "dc_revenue", "field": "market_rent_per_kw_month", "value": 187.5 }, "variance": null } ] } ```