# The confidence score The separate [record confidence scores](record-scoring-v3.md) export v3.2a assay-validation and v3.2b independent-study probabilities. This page specifies the preserved legacy 0-3 annotation score. The final stage of database processing assigns a confidence score to each TCR:peptide:MHC complex, computed from the reported ``method`` entries. The score combines sequencing confidence, identification confidence and verification confidence. The rule summaries below are generated from the scoring functions. Sequencing confidence uses the sequencing method, single-cell flag, frequency and available support counts. Identification confidence uses the assignment method and frequency; verification confidence uses the reported verification method. The following thresholds describe `vdjdb.score.confidence`. Frequency is a fraction from 0 to 1. Within each component, the first matching row takes precedence; method matches use substrings of the lowercased field. | Component | Criterion | Points | |---|---|---| | Sequencing | Nonempty single-cell flag other than `no` | 3 | | Sequencing | `sanger` | 3 with support count at least 2; otherwise 2 | | Sequencing | `amplicon-seq` | 3 with frequency at least 0.01 and support count at least 2 when known; otherwise 1 | | Sequencing | Other or missing method | 1 | | Identification | `culture` or `cloning` | 1 with frequency at least 0.5; otherwise 0 | | Identification | `sort`, `beads`, `separation` or `stain` | 1 with frequency at least 0.05; otherwise 0 | | Identification | `targets` | 1 with frequency at least 0.25; otherwise 0 | | Verification | `direct` | 3 | | Verification | `targets` | 2 | | Verification | `sort`, `beads`, `separation` or `stain` | 1 | Unmatched identification or verification methods contribute 0 points. The Sanger support count uses `method.frequency.count` where available, otherwise the numerator of a ratio frequency. Unknown counts do not disqualify the amplicon frequency rule. For an observation without a structure, the score is the smaller of sequencing confidence and the sum of identification and verification confidence. A verification method recognised by the scorer sets sequencing confidence to 3. A nonempty `meta.structure.id` sets the score to 3; QC requires a PDB entry identifier in that field. Among records that point to the same unique complex entry, that is the same set of unique **complex** fields - independent submissions, replicas, and so on - the maximal score is taken. This maximum groups the alpha and beta junctions and V/J calls, receptor species, both MHC chains, MHC class and peptide. It does not group by donor or publication. A shared score therefore does not mean every observation received the strongest assay. score | description ------|---------------------- 0 | Low confidence/no information - a critical aspect of sequencing/specificity validation is missing 1 | Moderate confidence - no verification / poor TCR sequence confidence 2 | High confidence - has some specificity verification, good TCR sequence confidence 3 | Very high confidence - has extensive verification or structural data ## Interpreting the score The score ranks support for the sequence-to-pMHC annotation. It is not a probability, an affinity estimate, a measure of killing or cytokine production, or a clinical-response prediction. Multimer binding and functional responses establish different properties; retain the methods alongside the score. Single-cell sequencing improves sequence confidence but still requires evidence linking that sequence to the reported pMHC. See {doc}`chunk-format` for assay attribution and unresolved peptide pools. Method vocabulary and score matching are distinct. A source-reported method can pass vocabulary review without matching a scoring rule. Do not rename a readout to obtain more points or infer an unreported validation experiment from a high shared score. ## Score rules The table below is rendered from `vdjdb.score.confidence` while this page builds. ```{vdjdb-score-rules} ``` ## Record confidence score v3 The separate [record confidence v3 specification](record-scoring-v3.md) defines the Bayesian evidence pipeline, frozen model, parameter defaults, compressed record-ID linked outputs, validation comparisons and false-positive denominators. It combines motif, publication, donor and predicted-structure evidence while retaining the legacy score above. The dedicated page includes the Python API and optional inference modes.