generated: '2026-09-06' method: searched source: >- https://production-accure.eu.auth0.com/.well-known/openid-configuration ; https://cdn.prod.website-files.com/67f3b2b2af7509d6ee127613/67f3b2b2af7509d6ee127a39_ACCURE_ISO27001_2022_certificate.pdf ; https://www.accure.net/battery-analytics/battery-intelligence name: ACCURE Battery Intelligence conformance and compliance summary: >- Two verifiable conformance signals: an OpenID Connect / OAuth 2.0 authorization server (ACCURE's own Auth0 tenant, metadata served anonymously) and a published, in-date ISO/IEC 27001:2022 certificate issued by DQS GmbH. No API-level domain standard could be verified, because ACCURE publishes no machine-readable contract to read one from. conformance: - id: oauth2 conforms: true evidence: https://production-accure.eu.auth0.com/.well-known/openid-configuration note: >- RFC 8414 authorization server metadata is served at /.well-known/oauth-authorization-server on ACCURE's Auth0 tenant, advertising authorization_code, client_credentials, refresh_token, device_code and token-exchange grants. - id: oidc conforms: true evidence: https://production-accure.eu.auth0.com/.well-known/openid-configuration note: >- OpenID Connect Discovery 1.0 document with issuer, jwks_uri, userinfo_endpoint and end_session_endpoint. id_token signing algs RS256/PS256/HS256. - id: pkce conforms: true evidence: https://production-accure.eu.auth0.com/.well-known/openid-configuration note: 'code_challenge_methods_supported includes S256 (RFC 7636).' - id: rfc7009-token-revocation conforms: true evidence: https://production-accure.eu.auth0.com/oauth/revoke note: 'revocation_endpoint published in the discovery document.' - id: iso-27001 conforms: true evidence: https://cdn.prod.website-files.com/67f3b2b2af7509d6ee127613/67f3b2b2af7509d6ee127a39_ACCURE_ISO27001_2022_certificate.pdf note: >- ISO/IEC 27001:2022 certificate for ACCURE Battery Intelligence GmbH, Oranienstrasse 9, 52066 Aachen, Germany. Certificate registration no. 316212 61 ISMS22, issued by DQS GmbH (accredited body, Frankfurt am Main), date of certification 2024-09-04, valid 2024-09-04 to 2027-09-03. Scope: "Development, operation, and maintenance of battery analytics products, including the provisioning of associated support and consulting services." Statement of Applicability v1.0 of 2024-02-15. Linked from the accure.net site footer as "ISO 27001". - id: rfc9457 conforms: false evidence: 'No public contract or error reference. Not observable.' - id: json:api conforms: false evidence: 'No public contract. Not observable.' - id: odata conforms: false evidence: 'No public contract. Not observable.' - id: scim conforms: false evidence: >- ACCURE states the platform supports single sign-on, but no SCIM schema URN or provisioning endpoint is published. Not observable. domain_standards: regime: energy_utilities checked: - id: opc-ua conforms: false claimed: true evidence: https://www.accure.net/battery-analytics/battery-intelligence note: >- PROSE CLAIM ONLY, DELIBERATELY NOT CREDITED. ACCURE's product page states "Open REST and OPC-UA interfaces stream data to CMMS or market-dispatch tools, while SFTP and API endpoints pull historical logs from virtually any BMS." OPC UA (IEC 62541) is a genuine domain standard for this market and the claim is plausible, but domain_standard_conformance reads the CONTRACT, not a marketing page. ACCURE publishes no OPC UA address-space model, no nodeset file, and no machine-readable contract of any kind, so nothing can be verified. Recorded as a claim to chase, not as a conformance. - id: ieee-2030-5 conforms: false evidence: 'Not named on any ACCURE public surface. Not observable.' - id: openadr conforms: false evidence: 'Not named on any ACCURE public surface. Not observable.' - id: green-button conforms: false evidence: 'Not named on any ACCURE public surface. Not observable.' - id: espi conforms: false evidence: 'Not named on any ACCURE public surface. Not observable.' - id: smart-energy-code conforms: false evidence: 'Not named on any ACCURE public surface. Not observable.' note: >- Reward-only dimension. ACCURE's market does have standards worth declaring (OPC UA / IEC 62541 for industrial telemetry, IEEE 2030.5 and OpenADR for grid interaction), and ACCURE says in prose that it speaks one of them. The gap is that it is declared nowhere a machine can read it. certifications: - name: ISO/IEC 27001:2022 status: certified certificate_number: 316212 61 ISMS22 issuer: DQS GmbH accredited_body: DQS GmbH, August-Schanz-Strasse 21, 60433 Frankfurt am Main, Germany certified: '2024-09-04' valid_from: '2024-09-04' valid_until: '2027-09-03' scope: >- Development, operation, and maintenance of battery analytics products, including the provisioning of associated support and consulting services. url: https://cdn.prod.website-files.com/67f3b2b2af7509d6ee127613/67f3b2b2af7509d6ee127a39_ACCURE_ISO27001_2022_certificate.pdf gaps: - 'No SOC 2 report or attestation is published.' - >- The in-product trust centre route (/account/trust-center in the platform SPA) is behind Auth0; no public trust page exists at trust.accure.net, security.accure.net, accure.net/trust or accure.net/security (all miss).