generated: '2026-07-27' method: searched source: https://consumerdatastandardsaustralia.github.io/standards/ docs: https://consumerdatastandardsaustralia.github.io/standards/#versioning note: > Alinta Energy publishes no versioning, deprecation or SLA document of its own. Its lifecycle obligations are set entirely by the Consumer Data Standards and the CDR rules, which bind it as a designated energy data holder. The one lifecycle surface Alinta genuinely operates is the CDR Common Discovery pair — a live, public, machine-readable status and planned-outage feed on its own infrastructure. versioning: scheme: header-per-endpoint (x-v / x-min-v) standards_version: 1.36.0 current_endpoint_versions: listEnergyPlans: '1' getEnergyPlanDetail: '3' listElectricityServicePoints: '2' getElectricityServicePointDetail: '2' listEnergyAccounts: '2' getEnergyAccountDetail: '4' getBillingForEnergyAccount: '3' getStatus: '1' getOutages: '1' getCustomerDetail: '2' negotiation: Client sends x-v (mandatory); an unsupported version returns HTTP 406. confirmed_live: 'x-v 1 on /discovery/status and /discovery/outages; x-v 3 on /energy/plans/{planId}.' docs: https://consumerdatastandardsaustralia.github.io/standards/#endpoint-versioning deprecation: policy: > Endpoint versions are superseded and retired through the Consumer Data Standards Future Dated Obligation (FDO) process: each change names a date by which data holders MUST implement the new endpoint version and a later date from which they MAY retire the prior version. Obsolete versions stay published in the standard for reference. examples_binding_alinta: - endpoint: Get Generic Plan Detail obligation: Data holders MUST implement v3 by 11 November 2024; MAY retire v2 from 3 March 2025. - endpoint: Get Energy Account Detail obligation: Data holders MUST implement v4 by 11 November 2024; MAY retire v3 from 3 March 2025. - endpoint: Transaction Security Ciphers obligation: Data holders and recipients MUST only support BCP195-recommended ciphers by 17 March 2025. obsolete_versions_documented: true policy_url: https://consumerdatastandardsaustralia.github.io/standards/#versioning obligation_schedule: https://consumerdatastandardsaustralia.github.io/standards/#future-dated-obligations sunset_header: false note: RFC 8594 Sunset/Deprecation headers are not used; retirement is scheduled by dated obligation, not by header. status: status_endpoints: - url: https://public.cdr.alintaenergy.com.au/cds-au/v1/discovery/status brand: Alinta Energy operation: getStatus confirmed: 'HTTP 200 on 2026-07-27 — {"data":{"status":"OK","updateTime":"2026-07-27T20:26:07Z","explanation":"All services operational"}}' - url: https://public.cdr.lumoenergy.com.au/cds-au/v1/discovery/status brand: Lumo Energy (Alinta''s second retail brand, separately registered data holder) operation: getStatus confirmed: HTTP 200 outage_endpoints: - url: https://public.cdr.alintaenergy.com.au/cds-au/v1/discovery/outages brand: Alinta Energy operation: getOutages confirmed: 'HTTP 200 on 2026-07-27 — {"data":{"outages":[]}}' human_status_page: none note: > These are machine-readable status endpoints, not an HTML status page. They are the only operational-transparency surface Alinta publishes, and they are mandated rather than voluntary. sla: availability_target: 99.5% per month availability_scope: All CDR endpoints, authenticated and unauthenticated; excludes planned outages. planned_outage_notice: At least one week's lead time for normal outages, published to Data Recipient Software Products; critical security fixes may occur without notice. performance: rule: 95% of calls per hour within the nominated response-time threshold. thresholds: unauthenticated: 1500ms high_priority: 1000ms (includes Get Status, Get Outages, Get Energy Accounts, Get Energy Account Detail, Get Balance For Energy Account, Get Invoices For Account, Get Customer, Get Customer Detail) low_priority: 1500ms unattended: 4000ms large_payload: 6000ms (Get Bulk Billing, Get Billing For Specific Accounts) secondary_request: 1000ms (data holders) / 1500ms (secondary data holders) large_secondary_request: 1500ms (data holders) / 4500ms (secondary data holders) source: https://consumerdatastandardsaustralia.github.io/standards/#non-functional-requirements note: Enforced by the ACCC under the CDR rules; there is no Alinta-authored SLA document. reporting: mechanism: CDR Get Metrics admin endpoint (data holder reporting to the regulator, not publicly readable). deprecated_operations: []