openapi: 3.1.0 info: title: Axle 1. Authentication 5. Data API description: For full documentation please see our official docs at docs.axle.energy version: 1.4.6 servers: - url: https://api.axle.energy tags: - name: 5. Data description: Send asset metrics to Axle, for analysis and optimisation purposes paths: /data/readings: post: tags: - 5. Data summary: Post Readings description: 'Send asset readings data to Axle using the generic readings format. This endpoint accepts compressed data using gzip encoding. Returns statuses of the processed readings, indicating whether each reading was accepted or rejected. **Direction convention:** for readings that can be either positive or negative (e.g. `boundary_import_kw`, `battery_inverter_import_kw`), a positive value denotes *import* (power flowing in from the grid, or into the battery) and a negative value denotes *export* (power flowing out to the grid, or out of the battery). All other reading types are unidirectional; the required sign for each `label` is documented in the `ReadingDataPointLabel` schema below.' operationId: post_readings_data_readings_post requestBody: content: application/json: schema: $ref: '#/components/schemas/ReadingsDataPoints' required: true responses: '200': description: Successfully recorded readings with processing summary content: application/json: schema: $ref: '#/components/schemas/ReadingsResponse' '400': description: Invalid data format or validation error '403': description: Permission denied '500': description: Server error while recording readings '422': description: Validation Error content: application/json: schema: $ref: '#/components/schemas/HTTPValidationError' security: - OAuth2PasswordBearer: [] components: schemas: ReadingDataPoint: properties: asset_id: type: string format: uuid title: Asset Id description: ID of the asset start_timestamp: type: string format: date-time title: Start Timestamp description: Start time of the reading end_timestamp: type: string format: date-time title: End Timestamp description: End time of the reading value: type: number title: Value description: Value of the reading label: allOf: - $ref: '#/components/schemas/ReadingDataPointLabel' description: Label for the reading type: object required: - asset_id - start_timestamp - end_timestamp - value - label title: ReadingDataPoint description: Reading data for a single asset. ReadingsDataPoints: properties: readings: items: $ref: '#/components/schemas/ReadingDataPoint' type: array title: Readings description: List of readings to be submitted type: object required: - readings title: ReadingsDataPoints description: Readings data for multiple assets. ReadingDataPointLabel: type: string enum: - boundary_import_kw - battery_inverter_import_kw - charger_consumption_energy_kwh - charger_lifetime_consumption_energy_kwh - boundary_lifetime_import_energy_kwh - boundary_lifetime_export_energy_kwh - provisional_consumption_kwh - solar_power_kw - battery_state_of_charge_pct - battery_stored_energy_kwh title: ReadingDataPointLabel description: 'The type of reading being submitted. - boundary_import_kw: Instantaneous power import from the grid in kW. Positive indicates power imported from the grid, negative indicates power exported to the grid. - battery_inverter_import_kw: Instantaneous inverter power into the battery in kW. Positive indicates power into the battery (charging), negative indicates power out of the battery (discharging). - charger_consumption_energy_kwh: Total energy consumed by the charger in kWh in a 30min interval. Must be >= 0. - charger_lifetime_consumption_energy_kwh: Total energy consumed by the charger in kWh in its lifetime. Must be >= 0. - boundary_lifetime_import_energy_kwh: Cumulative lifetime energy imported across the site boundary in kWh. A monotonic non-decreasing register; must be >= 0. - boundary_lifetime_export_energy_kwh: Cumulative lifetime energy exported across the site boundary in kWh. A monotonic non-decreasing register; must be >= 0. - provisional_consumption_kwh: Provisional consumption data in kWh. Must be >= 0. - solar_power_kw: Instantaneous solar generation in kW. Must be >= 0. - battery_state_of_charge_pct: Instantaneous state of charge of the battery in percentage. Must be between 0 and 100 (inclusive). - battery_stored_energy_kwh: Stored energy in the battery in kWh. Must be >= 0.' ValidationError: properties: loc: items: anyOf: - type: string - type: integer type: array title: Location msg: type: string title: Message type: type: string title: Error Type type: object required: - loc - msg - type title: ValidationError ReadingsResponse: properties: responses: items: $ref: '#/components/schemas/ReadingResponse' type: array title: Responses description: List of responses for each reading submission type: object required: - responses title: ReadingsResponse description: Response model for a batch of readings submissions. ReadingResponse: properties: asset_id: type: string format: uuid title: Asset Id description: ID of the asset start_timestamp: type: string format: date-time title: Start Timestamp description: Start time of the reading end_timestamp: type: string format: date-time title: End Timestamp description: End time of the reading label: allOf: - $ref: '#/components/schemas/ReadingDataPointLabel' description: Label for the reading accepted: type: boolean title: Accepted description: Whether the reading was accepted error: type: string title: Error description: Error message if the reading was rejected type: object required: - asset_id - start_timestamp - end_timestamp - label - accepted title: ReadingResponse description: Response model for a single reading submission. HTTPValidationError: properties: detail: items: $ref: '#/components/schemas/ValidationError' type: array title: Detail type: object title: HTTPValidationError securitySchemes: OAuth2PasswordBearer: type: oauth2 flows: password: scopes: {} tokenUrl: auth/token-form