generated: '2026-08-16' method: searched source: https://foresight-dx.com/ note: >- Foresight Diagnostics publishes no API and therefore has no API-standards conformance surface — there is no OpenAPI, AsyncAPI, GraphQL SDL, OAuth metadata document or RFC 9457 error envelope to assert against. What it does publish, in the site-wide footer of every page on its own domain, is a set of laboratory and information-security certifications with named certificate numbers, plus a downloadable ISO 27001 certificate hosted on that same domain. Those are recorded below. The certifications are organizational and laboratory accreditations, NOT API or interoperability conformance; they are captured here because they are the only verifiable compliance program the company publishes. api_standards: - id: openapi conforms: false evidence: >- No OpenAPI/Swagger document at any probed path on foresight-dx.com (/openapi.json, /openapi.yaml, /swagger.json, /v1/openapi.json, /api-docs, /docs, /redoc all HTTP 404). No API host exists to probe. - id: asyncapi conforms: false evidence: No event, streaming or webhook surface is documented or advertised. - id: graphql conforms: false evidence: https://foresight-dx.com/graphql returned HTTP 404. - id: oauth2 conforms: false evidence: >- /.well-known/oauth-authorization-server and /.well-known/openid-configuration both returned HTTP 404. No authorization server is published. - id: rfc9457 conforms: false evidence: No API contract exists in which to declare application/problem+json. - id: fhir conforms: false evidence: >- No FHIR endpoint, capability statement or interoperability claim is published. Results are delivered as clinical laboratory reports, not through a health-data API. - id: hl7v2 conforms: false evidence: >- No HL7 v2 interface is advertised on the public site, though a CLIA laboratory of this kind would typically exchange orders and results with ordering institutions over private, contracted interfaces that are not public. certifications: - id: iso-27001 name: ISO/IEC 27001:2013 Information Security Management System conforms: true identifier: BMSC-049-2312-ISMS1012 evidence: >- Certificate number published in the footer of every page on foresight-dx.com and the certificate PDF served from the company's own domain at https://foresight-dx.com/wp-content/uploads/2024/07/Foresight-ISO-27001.pdf (HTTP 200, application/pdf, 897,176 bytes). - id: clia name: CLIA certification (Clinical Laboratory Improvement Amendments) conforms: true identifier: 06D2287941 evidence: >- CLIA number 06D2287941 published in the site-wide footer of foresight-dx.com. - id: cap name: College of American Pathologists (CAP) laboratory accreditation conforms: true identifier: '9346637' evidence: >- CAP number 9346637 published in the site-wide footer of foresight-dx.com. regulatory_status: - id: fda-clearance conforms: false evidence: >- The company states on every page that "Foresight CLARITY has not been cleared or approved by the US Food and Drug Administration (FDA)" and that it was developed and its performance characteristics determined by Foresight's central laboratory — i.e. it is offered as a laboratory-developed test (LDT).