{ "$schema": "https://json-schema.org/draft/2020-12/schema", "$id": "https://raw.githubusercontent.com/api-evangelist/southern-california-edison/refs/heads/main/json-schema/southern-california-edison-drpep-layers-schema.json", "title": "SCE DRPEP feature layer attribute schemas", "description": "JSON Schema for the attribute shapes of the marquee SCE DRPEP ArcGIS feature layers and tables, derived from the live ArcGIS layer descriptors fetched 2026-07-27. Esri field types are mapped to JSON types and preserved in x-esri-field-type.", "x-generated": "2026-07-27", "x-method": "derived", "x-source": "arcgis/*-featureserver.json + live ArcGIS layer descriptors", "$defs": { "IcaCircuitSegment": { "type": "object", "title": "ICA - Circuit Segments", "description": "Attributes of DRPEP ICA_Layer layer 0 (ICA - Circuit Segments).", "x-source": "https://drpep.sce.com/arcgis_server/rest/services/Hosted/ICA_Layer/FeatureServer/0?f=json", "properties": { "system_name": { "type": "string", "title": "System Name", "x-esri-field-type": "esriFieldTypeString" }, "substation_name": { "type": "string", "title": "Substation Name", "x-esri-field-type": "esriFieldTypeString" }, "substation_voltage": { "type": "string", "title": "Substation Voltage", "x-esri-field-type": "esriFieldTypeString" }, "circuit_name": { "type": "string", "title": "Circuit Name", "x-esri-field-type": "esriFieldTypeString" }, "circuit_voltage": { "type": "string", "title": "Circuit Voltage", "x-esri-field-type": "esriFieldTypeString" }, "section_id": { "type": "number", "title": "Segment ID", "x-esri-field-type": "esriFieldTypeDouble" }, "node_id": { "type": "string", "title": "Node ID", "x-esri-field-type": "esriFieldTypeString" }, "uniform_generation": { "type": "number", "title": "Uniform Generation Static Grid", "x-esri-field-type": "esriFieldTypeDouble" }, "uniform_generation_op_flex": { "type": "string", "title": "Uniform Generation OpFlex", "x-esri-field-type": "esriFieldTypeString" }, "ica_overall_pv": { "type": "number", "title": "Photovoltaic Static Grid", "x-esri-field-type": "esriFieldTypeDouble" }, "ica_overall_pv_op_flex": { "type": "string", "title": "Photovoltaic OpFlex", "x-esri-field-type": "esriFieldTypeString" }, "ica_overall_load": { "type": "string", "title": "Uniform Load", "x-esri-field-type": "esriFieldTypeString" }, "disclaimer": { "type": "string", "title": "Disclaimer", "x-esri-field-type": "esriFieldTypeString" }, "note": { "type": "string", "title": "Note", "x-esri-field-type": "esriFieldTypeString" }, "lgp_flag": { "type": "string", "title": "LGP Flag", "x-esri-field-type": "esriFieldTypeString" }, "most_limiting_criteria_ug_sg": { "type": "string", "title": "Most Limiting Criteria -Uniform Generation Static Grid", "x-esri-field-type": "esriFieldTypeString" }, "most_limiting_criteria_ug_of": { "type": "string", "title": "Most Limiting Criteria-Uniform Gen Op Flex", "x-esri-field-type": "esriFieldTypeString" }, "most_limiting_criteria_lsg": { "type": "string", "title": "Most Limiting Criteria -Load Static Grid", "x-esri-field-type": "esriFieldTypeString" }, "most_limiting_criteria_pv_sg": { "type": "string", "title": "Most Limiting Criteria -Photovoltaic Static Grid", "x-esri-field-type": "esriFieldTypeString" }, "most_limiting_criteria_pv_of": { "type": "string", "title": "Most Limiting Criteria -Photovoltaic Op Flex", "x-esri-field-type": "esriFieldTypeString" }, "phase": { "type": "string", "x-esri-field-type": "esriFieldTypeString" }, "download_link": { "type": "string", "x-esri-field-type": "esriFieldTypeString" }, "download_link_microgrid": { "type": "string", "x-esri-field-type": "esriFieldTypeString" }, "download_link_forecast": { "type": "string", "x-esri-field-type": "esriFieldTypeString" }, "download_link_microgrid_forecas": { "type": "string", "title": "download_link_microgrid_forecast", "x-esri-field-type": "esriFieldTypeString" }, "changed_date": { "type": "string", "x-esri-field-type": "esriFieldTypeString" }, "changed_date_forecast": { "type": "string", "x-esri-field-type": "esriFieldTypeString" }, "objectid": { "type": "integer", "title": "OBJECTID", "x-esri-field-type": "esriFieldTypeOID" }, "SHAPE__Length": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" } }, "additionalProperties": false }, "Substation": { "type": "object", "title": "Substations", "description": "Attributes of DRPEP ICA_Layer layer 16 (Substations).", "x-source": "https://drpep.sce.com/arcgis_server/rest/services/Hosted/ICA_Layer/FeatureServer/16?f=json", "properties": { "subst_id": { "type": "number", "title": "Substation ID", "x-esri-field-type": "esriFieldTypeDouble" }, "sub_name": { "type": "string", "title": "Substation Name", "x-esri-field-type": "esriFieldTypeString" }, "sys_name": { "type": "string", "title": "System Name", "x-esri-field-type": "esriFieldTypeString" }, "sub_type": { "type": "string", "title": "Substation Type Old", "x-esri-field-type": "esriFieldTypeString" }, "sub_type_legend": { "type": "string", "title": "Substation Type", "x-esri-field-type": "esriFieldTypeString" }, "substation_voltage": { "type": "string", "title": "Substation Voltage", "x-esri-field-type": "esriFieldTypeString" }, "existing_gen": { "type": "number", "title": "Existing Generaion", "x-esri-field-type": "esriFieldTypeDouble" }, "queued_gen": { "type": "number", "title": "Queued Generation", "x-esri-field-type": "esriFieldTypeDouble" }, "total_gen": { "type": "number", "title": "Total Generation", "x-esri-field-type": "esriFieldTypeDouble" }, "projected_load": { "type": "number", "title": "Projected Load", "x-esri-field-type": "esriFieldTypeDouble" }, "penetration_level": { "type": "number", "title": "Penetration Level", "x-esri-field-type": "esriFieldTypeDouble" }, "max_remain_cap": { "type": "number", "title": "Maxium Remaining Capacity", "x-esri-field-type": "esriFieldTypeDouble" }, "note": { "type": "string", "title": "Note", "x-esri-field-type": "esriFieldTypeString" }, "objectid": { "type": "integer", "title": "OBJECTID", "x-esri-field-type": "esriFieldTypeOID" } }, "additionalProperties": false }, "ServiceTerritory": { "type": "object", "title": "SCE Service Territory", "description": "Attributes of DRPEP ICA_Layer layer 19 (SCE Service Territory).", "x-source": "https://drpep.sce.com/arcgis_server/rest/services/Hosted/ICA_Layer/FeatureServer/19?f=json", "properties": { "id": { "type": "number", "title": "ID", "x-esri-field-type": "esriFieldTypeDouble" }, "existing_gen": { "type": "number", "title": "Existing Generation", "x-esri-field-type": "esriFieldTypeDouble" }, "queued_gen": { "type": "number", "title": "Queued Generation", "x-esri-field-type": "esriFieldTypeDouble" }, "total_gen": { "type": "number", "title": "Total Generation", "x-esri-field-type": "esriFieldTypeDouble" }, "projected_load": { "type": "number", "title": "Projected Load", "x-esri-field-type": "esriFieldTypeDouble" }, "penetration_level": { "type": "number", "title": "Penetration Level", "x-esri-field-type": "esriFieldTypeDouble" }, "objectid": { "type": "integer", "title": "OBJECTID", "x-esri-field-type": "esriFieldTypeOID" }, "SHAPE__Length": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "SHAPE__Area": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" } }, "additionalProperties": false }, "DistributionCircuit": { "type": "object", "title": "Distribution Circuits", "description": "Attributes of DRPEP Distribution_circuits layer 0 (Distribution Circuits).", "x-source": "https://drpep.sce.com/arcgis_server/rest/services/Hosted/Distribution_circuits/FeatureServer/0?f=json", "properties": { "circuit_id": { "type": "string", "title": "CIRCUIT_ID", "x-esri-field-type": "esriFieldTypeString" }, "circuit_no": { "type": "string", "title": "CIRCUIT_NO", "x-esri-field-type": "esriFieldTypeString" }, "circuit_type": { "type": "string", "title": "CIRCUIT_TYPE", "x-esri-field-type": "esriFieldTypeString" }, "circt_nam": { "type": "string", "title": "CIRCT_NAM", "x-esri-field-type": "esriFieldTypeString" }, "circuit_voltage": { "type": "number", "title": "CIRCUIT_VOLTAGE", "x-esri-field-type": "esriFieldTypeDouble" }, "note": { "type": "string", "title": "NOTE", "x-esri-field-type": "esriFieldTypeString" }, "substation_voltage": { "type": "string", "title": "SUBSTATION_VOLTAGE", "x-esri-field-type": "esriFieldTypeString" }, "sub_name": { "type": "string", "title": "SUB_NAME", "x-esri-field-type": "esriFieldTypeString" }, "sys_name": { "type": "string", "title": "SYS_NAME", "x-esri-field-type": "esriFieldTypeString" }, "objectid": { "type": "integer", "title": "OBJECTID", "x-esri-field-type": "esriFieldTypeOID" }, "SHAPE__Length": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" } }, "additionalProperties": false }, "IcaConsolidatedRow": { "type": "object", "title": "ICA Single Consolidated Table", "description": "Attributes of DRPEP ICA_Tables layer 3 (ICA Single Consolidated Table).", "x-source": "https://drpep.sce.com/arcgis_server/rest/services/Hosted/ICA_Tables/FeatureServer/3?f=json", "properties": { "circuit_name": { "type": "string", "x-esri-field-type": "esriFieldTypeString" }, "circuit_id": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "circuit_voltage": { "type": "string", "x-esri-field-type": "esriFieldTypeString" }, "percent_15_cap": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "res_pct": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "com_pct": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "agr_pct": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "other_pct": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "ind_pct": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "sub_name": { "type": "string", "x-esri-field-type": "esriFieldTypeString" }, "subst_id": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "note_sub": { "type": "string", "x-esri-field-type": "esriFieldTypeString" }, "layer_identifier": { "type": "string", "x-esri-field-type": "esriFieldTypeString" }, "sys_name": { "type": "string", "x-esri-field-type": "esriFieldTypeString" }, "existing_gen": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "queued_gen": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "total_gen": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "projected_load": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "penetration_level": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "max_remain_cap": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "agr_total": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "com_total": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "ind_total": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "res_total": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "other_total": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "objectid": { "type": "integer", "title": "OBJECTID", "x-esri-field-type": "esriFieldTypeOID" } }, "additionalProperties": false }, "HistoricalCircuitLoadProfile": { "type": "object", "title": "Historical Circuit Load Profile", "description": "Attributes of DRPEP ICA_Tables layer 1 (Historical Circuit Load Profile).", "x-source": "https://drpep.sce.com/arcgis_server/rest/services/Hosted/ICA_Tables/FeatureServer/1?f=json", "properties": { "circuit_name": { "type": "string", "title": "CIRCUIT_NAME", "x-esri-field-type": "esriFieldTypeString" }, "voltage": { "type": "string", "title": "VOLTAGE", "x-esri-field-type": "esriFieldTypeString" }, "year": { "type": "number", "title": "YEAR", "x-esri-field-type": "esriFieldTypeDouble" }, "month": { "type": "number", "title": "MONTH", "x-esri-field-type": "esriFieldTypeDouble" }, "hour": { "type": "number", "title": "HOUR", "x-esri-field-type": "esriFieldTypeDouble" }, "min_load": { "type": "number", "title": "MIN_LOAD", "x-esri-field-type": "esriFieldTypeDouble" }, "max_load": { "type": "number", "title": "MAX_LOAD", "x-esri-field-type": "esriFieldTypeDouble" }, "min_load_mw": { "type": "number", "title": "MIN_LOAD_MW", "x-esri-field-type": "esriFieldTypeDouble" }, "max_load_mw": { "type": "number", "title": "MAX_LOAD_MW", "x-esri-field-type": "esriFieldTypeDouble" }, "substation": { "type": "string", "title": "SUBSTATION", "x-esri-field-type": "esriFieldTypeString" }, "monthlabel": { "type": "string", "title": "MONTHLABEL", "x-esri-field-type": "esriFieldTypeString" }, "objectid": { "type": "integer", "title": "OBJECTID", "x-esri-field-type": "esriFieldTypeOID" } }, "additionalProperties": false }, "GnaCircuit": { "type": "object", "title": "GNA - Circuits", "description": "Attributes of DRPEP GNA_Layer layer 2 (GNA - Circuits).", "x-source": "https://drpep.sce.com/arcgis_server/rest/services/Hosted/GNA_Layer/FeatureServer/2?f=json", "properties": { "ckt_capacity_y1": { "type": "string", "title": "CKT_CAPACITY_Y1", "x-esri-field-type": "esriFieldTypeString" }, "ckt_capacity_y2": { "type": "string", "title": "CKT_CAPACITY_Y2", "x-esri-field-type": "esriFieldTypeString" }, "ckt_capacity_y3": { "type": "string", "title": "CKT_CAPACITY_Y3", "x-esri-field-type": "esriFieldTypeString" }, "ckt_capacity_y4": { "type": "string", "title": "CKT_CAPACITY_Y4", "x-esri-field-type": "esriFieldTypeString" }, "ckt_capacity_y5": { "type": "string", "title": "CKT_CAPACITY_Y5", "x-esri-field-type": "esriFieldTypeString" }, "subst_capacity_y1": { "type": "string", "title": "SUBST_CAPACITY_Y1", "x-esri-field-type": "esriFieldTypeString" }, "subst_capacity_y2": { "type": "string", "title": "SUBST_CAPACITY_Y2", "x-esri-field-type": "esriFieldTypeString" }, "subst_capacity_y3": { "type": "string", "title": "SUBST_CAPACITY_Y3", "x-esri-field-type": "esriFieldTypeString" }, "subst_capacity_y4": { "type": "string", "title": "SUBST_CAPACITY_Y4", "x-esri-field-type": "esriFieldTypeString" }, "subst_capacity_y5": { "type": "string", "title": "SUBST_CAPACITY_Y5", "x-esri-field-type": "esriFieldTypeString" }, "circuit_name": { "type": "string", "title": "CIRCUIT_NAME", "x-esri-field-type": "esriFieldTypeString" }, "d_y1": { "type": "string", "title": "D_Y1", "x-esri-field-type": "esriFieldTypeString" }, "d_y2": { "type": "string", "title": "D_Y2", "x-esri-field-type": "esriFieldTypeString" }, "d_y3": { "type": "string", "title": "D_Y3", "x-esri-field-type": "esriFieldTypeString" }, "d_y4": { "type": "string", "title": "D_Y4", "x-esri-field-type": "esriFieldTypeString" }, "d_y5": { "type": "string", "title": "D_Y5", "x-esri-field-type": "esriFieldTypeString" }, "deficiency_year": { "type": "string", "title": "DEFICIENCY_YEAR", "x-esri-field-type": "esriFieldTypeString" }, "dp_max_legend": { "type": "number", "title": "DP_MAX_LEGEND", "x-esri-field-type": "esriFieldTypeDouble" }, "dp_y_max": { "type": "string", "title": "DP_Y_MAX", "x-esri-field-type": "esriFieldTypeString" }, "dp_y1": { "type": "string", "title": "DP_Y1", "x-esri-field-type": "esriFieldTypeString" }, "dp_y2": { "type": "string", "title": "DP_Y2", "x-esri-field-type": "esriFieldTypeString" }, "dp_y3": { "type": "string", "title": "DP_Y3", "x-esri-field-type": "esriFieldTypeString" }, "dp_y4": { "type": "string", "title": "DP_Y4", "x-esri-field-type": "esriFieldTypeString" }, "dp_y5": { "type": "string", "title": "DP_Y5", "x-esri-field-type": "esriFieldTypeString" }, "dy_max": { "type": "string", "title": "DY_MAX", "x-esri-field-type": "esriFieldTypeString" }, "element": { "type": "string", "title": "ELEMENT", "x-esri-field-type": "esriFieldTypeString" }, "gna_id": { "type": "string", "title": "GNA_ID", "x-esri-field-type": "esriFieldTypeString" }, "grid_need": { "type": "string", "title": "GRID_NEED", "x-esri-field-type": "esriFieldTypeString" }, "operating_date": { "type": "string", "title": "OPERATING_DATE", "x-esri-field-type": "esriFieldTypeString" }, "primary_driver": { "type": "string", "title": "PRIMARY_DRIVER", "x-esri-field-type": "esriFieldTypeString" }, "rating": { "type": "string", "title": "RATING", "x-esri-field-type": "esriFieldTypeString" }, "substation_name": { "type": "string", "title": "SUBSTATION_NAME", "x-esri-field-type": "esriFieldTypeString" }, "unit": { "type": "string", "title": "UNIT", "x-esri-field-type": "esriFieldTypeString" }, "year": { "type": "string", "title": "YEAR", "x-esri-field-type": "esriFieldTypeString" }, "circuit_volt": { "type": "string", "title": "CIRCUIT_VOLT", "x-esri-field-type": "esriFieldTypeString" }, "note": { "type": "string", "title": "NOTE", "x-esri-field-type": "esriFieldTypeString" }, "system_name": { "type": "string", "title": "SYSTEM_NAME", "x-esri-field-type": "esriFieldTypeString" }, "objectid": { "type": "integer", "title": "OBJECTID", "x-esri-field-type": "esriFieldTypeOID" }, "SHAPE__Length": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" } }, "additionalProperties": false }, "DdorCircuit": { "type": "object", "title": "DDOR - Circuits", "description": "Attributes of DRPEP DDOR_Layer layer 2 (DDOR - Circuits).", "x-source": "https://drpep.sce.com/arcgis_server/rest/services/Hosted/DDOR_Layer/FeatureServer/2?f=json", "properties": { "circuit_id": { "type": "string", "title": "CIRCUIT_ID", "x-esri-field-type": "esriFieldTypeString" }, "aace_cost_estimate": { "type": "string", "title": "AACE_COST_ESTIMATE", "x-esri-field-type": "esriFieldTypeString" }, "candidate_deferral": { "type": "string", "title": "CANDIDATE_DEFERRAL", "x-esri-field-type": "esriFieldTypeString" }, "circuit_name": { "type": "string", "title": "CIRCUIT_NAME", "x-esri-field-type": "esriFieldTypeString" }, "d_y1": { "type": "string", "title": "D_Y1", "x-esri-field-type": "esriFieldTypeString" }, "d_y2": { "type": "string", "title": "D_Y2", "x-esri-field-type": "esriFieldTypeString" }, "d_y3": { "type": "string", "title": "D_Y3", "x-esri-field-type": "esriFieldTypeString" }, "d_y4": { "type": "string", "title": "D_Y4", "x-esri-field-type": "esriFieldTypeString" }, "d_y5": { "type": "string", "title": "D_Y5", "x-esri-field-type": "esriFieldTypeString" }, "ddor_id": { "type": "string", "title": "DDOR_ID", "x-esri-field-type": "esriFieldTypeString" }, "ddor_project_id": { "type": "string", "title": "DDOR_PROJECT_ID", "x-esri-field-type": "esriFieldTypeString" }, "deficiency_year": { "type": "string", "title": "DEFICIENCY_YEAR", "x-esri-field-type": "esriFieldTypeString" }, "der_eligible_svc": { "type": "string", "title": "DER_ELIGIBLE_SVC", "x-esri-field-type": "esriFieldTypeString" }, "dp_max_legend": { "type": "string", "title": "DP_MAX_LEGEND", "x-esri-field-type": "esriFieldTypeString" }, "dp_y_max": { "type": "string", "title": "DP_Y_MAX", "x-esri-field-type": "esriFieldTypeString" }, "dp_y1": { "type": "string", "title": "DP_Y1", "x-esri-field-type": "esriFieldTypeString" }, "dp_y2": { "type": "string", "title": "DP_Y2", "x-esri-field-type": "esriFieldTypeString" }, "dp_y3": { "type": "string", "title": "DP_Y3", "x-esri-field-type": "esriFieldTypeString" }, "dp_y4": { "type": "string", "title": "DP_Y4", "x-esri-field-type": "esriFieldTypeString" }, "dp_y5": { "type": "string", "title": "DP_Y5", "x-esri-field-type": "esriFieldTypeString" }, "dy_max": { "type": "string", "title": "DY_MAX", "x-esri-field-type": "esriFieldTypeString" }, "equip_type": { "type": "string", "title": "EQUIP_TYPE", "x-esri-field-type": "esriFieldTypeString" }, "gna_id": { "type": "string", "title": "GNA_ID", "x-esri-field-type": "esriFieldTypeString" }, "grid_need": { "type": "string", "title": "GRID_NEED", "x-esri-field-type": "esriFieldTypeString" }, "operating_date": { "type": "string", "title": "OPERATING_DATE", "x-esri-field-type": "esriFieldTypeString" }, "proj_desc": { "type": "string", "title": "PROJ_DESC", "x-esri-field-type": "esriFieldTypeString" }, "proj_desc_add_info": { "type": "string", "title": "PROJ_DESC_ADD_INFO", "x-esri-field-type": "esriFieldTypeString" }, "proj_hist": { "type": "string", "title": "PROJ_HIST", "x-esri-field-type": "esriFieldTypeString" }, "system_name": { "type": "string", "title": "SYSTEM_NAME", "x-esri-field-type": "esriFieldTypeString" }, "substation_name": { "type": "string", "title": "SUBSTATION_NAME", "x-esri-field-type": "esriFieldTypeString" }, "note": { "type": "string", "title": "NOTE", "x-esri-field-type": "esriFieldTypeString" }, "unit": { "type": "string", "title": "UNIT", "x-esri-field-type": "esriFieldTypeString" }, "year": { "type": "string", "title": "YEAR", "x-esri-field-type": "esriFieldTypeString" }, "circuit_volt": { "type": "number", "title": "CIRCUIT_VOLT", "x-esri-field-type": "esriFieldTypeDouble" }, "objectid": { "type": "integer", "title": "OBJECTID", "x-esri-field-type": "esriFieldTypeOID" }, "SHAPE__Length": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" } }, "additionalProperties": false }, "LnbaShortTerm": { "type": "object", "title": "LNBA Short-term, Planning", "description": "Attributes of DRPEP LNBA_Layer layer 1 (LNBA Short-term, Planning).", "x-source": "https://drpep.sce.com/arcgis_server/rest/services/Hosted/LNBA_Layer/FeatureServer/1?f=json", "properties": { "circuit_name": { "type": "string", "title": "Circuit", "x-esri-field-type": "esriFieldTypeString" }, "section_id": { "type": "number", "title": "Section Id", "x-esri-field-type": "esriFieldTypeDouble" }, "circuit_voltage": { "type": "string", "title": "Circuit Voltage", "x-esri-field-type": "esriFieldTypeString" }, "substation_name": { "type": "string", "title": "Substation", "x-esri-field-type": "esriFieldTypeString" }, "system_name": { "type": "string", "title": "System", "x-esri-field-type": "esriFieldTypeString" }, "lnba_result_timeframe": { "type": "string", "title": "LNBA Timeframe", "x-esri-field-type": "esriFieldTypeString" }, "title_1": { "type": "string", "title": "Project 1", "x-esri-field-type": "esriFieldTypeString" }, "desc_1": { "type": "string", "title": "Description 1", "x-esri-field-type": "esriFieldTypeString" }, "date_1": { "type": "string", "title": "Operating Date 1", "x-esri-field-type": "esriFieldTypeString" }, "grid_services_1": { "type": "string", "title": "Distribution Service Required 1", "x-esri-field-type": "esriFieldTypeString" }, "lnba_results_1": { "type": "string", "title": "Estimated LNBA Range 1", "x-esri-field-type": "esriFieldTypeString" }, "title_2": { "type": "string", "title": "Project 2", "x-esri-field-type": "esriFieldTypeString" }, "desc_2": { "type": "string", "title": "Description 2", "x-esri-field-type": "esriFieldTypeString" }, "date_2": { "type": "string", "title": "Operating Date 2", "x-esri-field-type": "esriFieldTypeString" }, "grid_services_2": { "type": "string", "title": "Distribution Service Required 2", "x-esri-field-type": "esriFieldTypeString" }, "lnba_results_2": { "type": "string", "title": "Estimated LNBA Range 2", "x-esri-field-type": "esriFieldTypeString" }, "title_3": { "type": "string", "title": "Project 3", "x-esri-field-type": "esriFieldTypeString" }, "desc_3": { "type": "string", "title": "Description 3", "x-esri-field-type": "esriFieldTypeString" }, "date_3": { "type": "string", "title": "Operating Date 3", "x-esri-field-type": "esriFieldTypeString" }, "grid_services_3": { "type": "string", "title": "Distribution Service Required 3", "x-esri-field-type": "esriFieldTypeString" }, "lnba_results_3": { "type": "string", "title": "Estimated LNBA Range 3", "x-esri-field-type": "esriFieldTypeString" }, "objectid": { "type": "integer", "title": "OBJECTID", "x-esri-field-type": "esriFieldTypeOID" }, "SHAPE__Length": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" } }, "additionalProperties": false }, "PspsCircuit": { "type": "object", "title": "PSPS_Circuit", "description": "Attributes of DRPEP DRP_PSPS_Layer layer 1 (PSPS_Circuit).", "x-source": "https://drpep.sce.com/arcgis_server/rest/services/Hosted/DRP_PSPS_Layer/FeatureServer/1?f=json", "properties": { "objectid": { "type": "integer", "title": "OBJECTID", "x-esri-field-type": "esriFieldTypeOID" }, "circuit_type": { "type": "string", "title": "Circuit Type", "x-esri-field-type": "esriFieldTypeString" }, "circuit_name": { "type": "string", "title": "Circuit Name", "x-esri-field-type": "esriFieldTypeString" }, "substation_name": { "type": "string", "title": "Substation Name", "x-esri-field-type": "esriFieldTypeString" }, "psps_event": { "type": "string", "title": "PSPS Event", "x-esri-field-type": "esriFieldTypeString" }, "total_customers": { "type": "integer", "title": "Total Customers", "x-esri-field-type": "esriFieldTypeInteger" }, "deenergization_datetime": { "type": "string", "description": "Epoch milliseconds (Esri date field)", "title": "De-energization Datetime", "x-esri-field-type": "esriFieldTypeDate" }, "allclear_datetime": { "type": "string", "description": "Epoch milliseconds (Esri date field)", "title": "All Clear Datetime", "x-esri-field-type": "esriFieldTypeDate" }, "wind_speed": { "type": "string", "title": "Wind Speed", "x-esri-field-type": "esriFieldTypeString" }, "wind_gust": { "type": "string", "title": "Wind Gust", "x-esri-field-type": "esriFieldTypeString" }, "fpi": { "type": "string", "title": "Fire Protection Index", "x-esri-field-type": "esriFieldTypeString" }, "year": { "type": "integer", "title": "Year", "x-esri-field-type": "esriFieldTypeInteger" }, "minutes_deenergized": { "type": "number", "title": "Minutest De-energized", "x-esri-field-type": "esriFieldTypeDouble" }, "reenergization_datetime": { "type": "string", "description": "Epoch milliseconds (Esri date field)", "title": "Re-energization Datetime", "x-esri-field-type": "esriFieldTypeDate" }, "stationid": { "type": "string", "title": "Weather Station ID", "x-esri-field-type": "esriFieldTypeString" }, "SHAPE__Length": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" } }, "additionalProperties": false }, "FireThreatTier3": { "type": "object", "title": "CPUC_Fire_Threat_Areas____Tier_3___Extreme", "description": "Attributes of DRPEP Firemap layer 2 (CPUC_Fire_Threat_Areas____Tier_3___Extreme).", "x-source": "https://drpep.sce.com/arcgis_server/rest/services/Hosted/Firemap/FeatureServer/2?f=json", "properties": { "acres": { "type": "number", "title": "Acres", "x-esri-field-type": "esriFieldTypeDouble" }, "tierlvl": { "type": "number", "title": "TierLvl", "x-esri-field-type": "esriFieldTypeDouble" }, "shape_leng": { "type": "number", "title": "Shape_Leng", "x-esri-field-type": "esriFieldTypeDouble" }, "f_overlaps": { "type": "string", "title": "_overlaps", "x-esri-field-type": "esriFieldTypeString" }, "f_segments": { "type": "string", "title": "_segments", "x-esri-field-type": "esriFieldTypeString" }, "fid_drough": { "type": "integer", "title": "FID_Drough", "x-esri-field-type": "esriFieldTypeInteger" }, "type": { "type": "string", "title": "Type", "x-esri-field-type": "esriFieldTypeString" }, "objectid": { "type": "integer", "title": "OBJECTID", "x-esri-field-type": "esriFieldTypeOID" }, "SHAPE__Length": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" }, "SHAPE__Area": { "type": "number", "x-esri-field-type": "esriFieldTypeDouble" } }, "additionalProperties": false } } }