#--------------------------- MMS Temperature Module Configuration ---------------------------# #--------------------------- Controller Fan ---------------------------# [controller_fan my_controller_fan] pin: vivid:PA14 # Fan control pin stepper: manual_stepper selector_stepper, manual_stepper drive_stepper # Monitored steppers #--------------------------- Temperature Sensors ---------------------------# [temperature_sensor _PTC_Temper] sensor_pin: vivid:PA4 # Sensor input pin sensor_type: Generic 3950 # Sensor type pullup_resistor: 2200 # Pullup resistor value (ohms) min_temp: -20 # Minimum temperature (C) max_temp: 100 # Maximum temperature (C) [temperature_sensor ViViD_Dryer_L] sensor_type: AHT3X # Sensor type i2c_mcu: vivid # I2C MCU # i2c_bus: i2c1_PA9_PA10 i2c_software_scl_pin: vivid:PA9 # Software I2C clock pin i2c_software_sda_pin: vivid:PA10 # Software I2C data pin aht10_report_time: 5 # Report interval (seconds) min_temp: -20 # Minimum temperature (C) max_temp: 100 # Maximum temperature (C) [temperature_sensor ViViD_Dryer_R] sensor_type: AHT3X # Sensor type i2c_mcu: vivid # I2C MCU # i2c_bus: i2c3_PA7_PA6 i2c_software_scl_pin: vivid:PA7 # Software I2C clock pin i2c_software_sda_pin: vivid:PA6 # Software I2C data pin aht10_report_time: 5 # Report interval (seconds) min_temp: -20 # Minimum temperature (C) max_temp: 100 # Maximum temperature (C) #--------------------------- Heater Configuration ---------------------------# [heater_generic ViViD_Dryer] heater_pin: vivid:PC14 # Heater control pin sensor_type: temperature_combined # Combined sensor type sensor_list: aht10 ViViD_Dryer_L, aht10 ViViD_Dryer_R # Combined sensors combination_method: max # Combination method maximum_deviation: 100 # Maximum temperature deviation control: pid # Control method pid_Kp: 51.604 # PID proportional gain pid_Ki: 1.121 # PID integral gain pid_Kd: 593.934 # PID derivative gain min_temp: -20 # Minimum temperature (C) max_temp: 65 # Maximum temperature (C) #--------------------------- Heater Verification ---------------------------# [verify_heater ViViD_Dryer] max_error: 300 # Maximum temperature error check_gain_time: 600 # Gain check timeout (seconds) hysteresis: 10 # Hysteresis value heating_gain: 1 # Minimum heating gain #--------------------------- Heater Fan ---------------------------# [heater_fan ViViD_Dryer_Fan] pin: vivid:PC15 # Fan control pin max_power: 0.3 # Maximum power (0.0-1.0) shutdown_speed: 0 # Speed at shutdown (0.0-1.0) heater: ViViD_Dryer # Associated heater