#### ALL FULL DEFINITIONS PARAMETERS #### #### ALL GENERATED DEFINITIONS PARAMETERS #### Active fuel tuning enabled Active fuel tuning high #1 Active fuel tuning high #2 Active fuel tuning high #3 Active fuel tuning high #4 Active fuel tuning high #5 Active fuel tuning low #1 Active fuel tuning low #2 Active fuel tuning low #3 Active fuel tuning low #4 Active fuel tuning low #5 Active knock retard enabled Active knock retard high Active knock retard low Active knock retard max retard Active knock retard method Active knock retard min Active knock retard step AFM fuel AFM maximum voltage AFM minimum voltage Air temperature fuel compensation cranking Boost control activation pressure Boost control air temperature compensation Boost control duty lookup Boost control duty to pressure Boost control enabled Boost control fixed duty Boost control frequency Boost control max duty Boost control quick spool Boost control solenoid is normally open Boost control type Boost cut enabled Boost cut pressure Calibration ID Cam angle high Cam angle low Change per tuning cyle Closed loop target lambda Cold start idle air control system (P050A, P050B) Coolant thermostat temperature check enabled (P0128) Cranking fuel trim Delay after engine start Delay after injector re-start Driving recorder enabled(Off=35127,On=54814) ELD enabled Engine oil pressure sensor enabled Ethanol ECT cranking compensation Ethanol fuel compensation Ethanol ignition compensation Ethanol ignition multiplier Ethanol input enabled(Off=0,On=60) Ethanol percentage EVAP leak detection enabled (P0455 P0456 P0457) Flash check engine for knock enabled Forced induction enabled Fuel high #1 Fuel high #2 Fuel high #3 Fuel high #4 Fuel high #5 Fuel low #1 Fuel low #2 Fuel low #3 Fuel low #4 Fuel low #5 Fuel Pressure Gear ignition compensation Idle speed (after start) Idle Speed Ignition high #1 Ignition high #2 Ignition high #3 Ignition high #4 Ignition high #5 Ignition low #1 Ignition low #2 Ignition low #3 Ignition low #4 Ignition low #5 Injector size Injector Voltage Compensation Knock ignition limit high #1 Knock ignition limit high #2 Knock ignition limit high #3 Knock ignition limit high #4 Knock ignition limit high #5 Knock ignition limit low #1 Knock ignition limit low #2 Knock ignition limit low #3 Knock ignition limit low #4 Knock ignition limit low #5 Knock retard high Knock retard low Knock sensitivity high #1 Knock sensitivity high #2 Knock sensitivity high cylinder 1-2 Knock sensitivity high cylinder 3-4 Knock sensitivity high Knock sensitivity low #1 Knock sensitivity low #2 Knock sensitivity low cylinder 1-2 Knock sensitivity low cylinder 3-4 Knock sensitivity low Launch rpm #1 Launch rpm #2 Launch rpm recover #1 Launch rpm recover #2 MAP offset MAP scalar Maximum cam angle delta Maximum change Maximum ECT Maximum gear Maximum IAT Maximum lambda Maximum load delta Maximum load Maximum rpm delta Maximum rpm Maximum TPS Maximum VTC Minimum ECT for alternator control Minimum gear Minimum IAT Minimum IPW Minimum lambda Minimum load Minimum pressure for speed/density Minimum rpm Minimum TPS Minimum VTC Misfire detection Open loop Overall fuel trim Overrun cutoff MAP high cam (recover) Pit lane speed limit enabled Post Start Idle Speed Primary oxygen sensor enabled Rev limiter #1 Rev limiter #2 Rev limiter #3 Rev limiter #4 Rev limiter recover #1 Rev limiter recover #2 Rev limiter recover #3 Rev limiter recover #4 Revlimiter 1 Revlimiter 2 Revlimiter 3 Revlimiter 4 Revlimiter 5 Revlimiter 6 Revlimiter 7 Revlimiter Second ECT sensor enabled Secondary oxygen sensor enabled Speed limiter speed Start emissions reduction enabled SWINJOK Target lambda high Target lambda low Traction Control ignition retard value Traction control input(Off=0,On=4) Traction control input(Off=0,On=52) Traction control minimum rpm Traction control voltage offset Tuning method Update frequency Use corrected wideband Use fuel trims Use MAP fuel tables Use MAP to determine WOT(Off=1,On=0) VSA enabled VTEC Engagement VTEC rpm window Water temperature ignition retard Wideband input(Off=0,On=12) Wideband input(Off=0,On=14) Wideband input(Off=0,On=52) Wideband lambda Wideband voltage offset WOT lambda adjustment high #1 WOT lambda adjustment high #2 WOT lambda adjustment high #3 WOT lambda adjustment low #1 WOT lambda adjustment low #2 WOT lambda adjustment low #3 Write security word #1 Write security word #2