#### ALL FULL DEFINITIONS PARAMETERS #### #### ALL GENERATED DEFINITIONS PARAMETERS #### Active AFM Maximum gear Active fuel tuning enabled Active fuel tuning high #1 Active fuel tuning high #2 Active fuel tuning high #3 Active fuel tuning high #4 Active fuel tuning high #5 Active fuel tuning low #1 Active fuel tuning low #2 Active fuel tuning low #3 Active fuel tuning low #4 Active fuel tuning low #5 Active knock retard enabled Active knock retard high Active knock retard low Active knock retard max retard Active knock retard method Active knock retard min Active knock retard step AFM enabled AFM fuel Air temperature fuel compensation cranking Boost control activation pressure Boost control air temperature compensation Boost control duty lookup Boost control duty to pressure Boost control enabled Boost control fixed duty Boost control frequency S2000 Boost control frequency Boost control max duty Boost control quick spool Boost control solenoid is normally open Boost control type Boost cut enabled Boost cut pressure Calibration ID Cam angle high Cam angle low Change per tuning cyle Closed loop target lambda high load Closed loop target lambda Coil test enabled (P351 P352 P353 P354) Coolant thermostat temperature check enabled (P0128) #3 Cranking fuel trim Default PA value Delay after engine start Delay after injector re-start Delay in lambda reading EGR enabled EPS enabled Ethanol ECT cranking compensation Ethanol fuel compensation Ethanol ignition compensation Ethanol ignition multiplier Ethanol input enabled(Off=0,On=15) Ethanol input enabled(Off=0,On=60) Ethanol percentage EVAP FTP enabled (P0451 P0452 P0453 P1454) EVAP leak detection enabled (P0455 P0456 P0457) Flash check engine for knock enabled Fuel high #1 Fuel high #2 Fuel high #3 Fuel high #4 Fuel high #5 Fuel low #1 Fuel low #2 Fuel low #3 Fuel low #4 Fuel low #5 Fuel Pressure Gear ignition compensation Idle fuel table rpm high Idle fuel table rpm low Idle speed (after start) Ignition high #1 Ignition high #2 Ignition high #3 Ignition high #4 Ignition high #5 Ignition low #1 Ignition low #2 Ignition low #3 Ignition low #4 Ignition low #5 Ignition retard gear compensation Ignition retard rpm compensation Ignition retard throttle compensation Injector size Knock ignition limit high #1 Knock ignition limit high #2 Knock ignition limit high #3 Knock ignition limit high #4 Knock ignition limit high #5 Knock ignition limit low #1 Knock ignition limit low #2 Knock ignition limit low #3 Knock ignition limit low #4 Knock ignition limit low #5 Knock retard high Knock retard low Knock sensitivity high #1 Knock sensitivity high #2 Knock sensitivity high cylinder 1-2 Knock sensitivity high cylinder 3-4 Knock sensitivity high Knock sensitivity low #1 Knock sensitivity low #2 Knock sensitivity low cylinder 1-2 Knock sensitivity low cylinder 3-4 Knock sensitivity low Knock sensor enabled MAP offset MAP scalar Maximum cam angle delta Maximum change Maximum ECT Maximum gear Maximum IAT Maximum lambda Maximum load delta Maximum load Maximum plate deviation (P2101) Maximum rpm delta Maximum rpm Maximum TPS Maximum VTC Minimum ECT for alternator control Minimum gear Minimum IAT Minimum lambda Minimum load Minimum pressure for speed/density Minimum rpm Minimum TPS Minimum VTC Open loop Overall fuel trim Overrev rpm P0420 Malfunction Threshold Pit lane speed limit enabled Pit lane speed limit speed Purge/EVAP enabled RSSWGO45 RSSWGO67 Second ECT sensor enabled Secondary oxygen sensor enabled Speed limiter rpm Speed limiter speed Target lambda high Target lambda low TPlate Normal Traction Control ignition retard value Traction control input(Off=0,On=4) Traction control input(Off=0,On=52) Traction control input(Off=0,On=6) Traction control minimum rpm Traction control voltage offset Tuning method Update frequency Use corrected wideband Use fuel trims Use MAP fuel tables VSA enabled VTC enabled VTC WOT table enabled(Off=160,On=141) VTEC engage minimum speed VTEC oil pressure switch enabled Water temperature ignition compensation hot low Water temperature ignition retard Wideband input(Off=0,On=12) Wideband input(Off=0,On=14) Wideband input(Off=0,On=4) Wideband input(Off=0,On=52) Wideband lambda Wideband voltage offset WOT lambda adjustment high #1 WOT lambda adjustment high #2 WOT lambda adjustment high #3 WOT lambda adjustment low #1 WOT lambda adjustment low #2 WOT lambda adjustment low #3