#### ALL FULL DEFINITIONS PARAMETERS #### #### ALL GENERATED DEFINITIONS PARAMETERS #### Active AFM Change per tuning cyle Active AFM Closed loop Active AFM Delay after engine start Active AFM Delay after injector re-start Active AFM Delay in lambda reading Active AFM Fuel Smoothing Active AFM fuel tuning enabled Active AFM Lambda target (closed loop) Active AFM Lambda target (open loop) Active AFM Maximum change Active AFM Maximum ECT Active AFM Maximum gear Active AFM Maximum IAT Active AFM Maximum lambda Active AFM Maximum load Active AFM Maximum rpm Active AFM Maximum TPS Active AFM Maximum VTC Active AFM Minimum ECT Active AFM Minimum gear Active AFM Minimum IAT Active AFM Minimum lambda Active AFM Minimum load Active AFM Minimum rpm Active AFM Minimum TPS Active AFM Minimum VTC Active AFM Open loop Active AFM Update frequency Active AFM Use corrected wideband Active AFM Use fuel trims Active AFN Use fuel trims Active Closed loop Active Fuel Smoothing Active fuel tuning enabled Active fuel tuning high #1 Active fuel tuning high #2 Active fuel tuning high #3 Active fuel tuning high #4 Active fuel tuning high #5 Active fuel tuning low #1 Active fuel tuning low #2 Active fuel tuning low #3 Active fuel tuning low #4 Active fuel tuning low #5 Active knock retard enabled Active knock retard high Active knock retard low Active knock retard max retard Active knock retard method Active knock retard min Active knock retard step AFM enabled AFM flow AFM fuel Air temperature fuel compensation cranking Air temperature fuel compensation low flow Boost control activation pressure(Off=504032,On=1) Boost control activation pressure Boost control air temperature compensation Boost control duty lookup Boost control duty to pressure Boost control enabled Boost control fixed duty Boost control frequency S2000 Boost control frequency Boost control max duty Boost control quick spool Boost control solenoid is normally open Boost control type Boost cut enabled Boost cut pressure Calibration ID Cam angle high Cam angle low Change per tuning cyle Closed loop target lambda #1 Closed loop target lambda high load Closed loop target lambda low load Closed loop target lambda Cold start idle air control system (P050A, P050B) enabled Cold start idle air control system (P050A, P050B) Coolant thermostat temperature check enabled (P0128) Coolant thermostat temperature check enabled(P0128) Cranking (seq mode) fuel direct ratio Cranking fuel trim Cruise control enabled(Off= 255, On= 16) enabled Default PA value Delay after engine start Delay after injector re-start Delay in lambda reading EGR enabled EGR flow malfunction (P0400) enabled EGR flow malfunction (P0400) ELD enabled Engine oil level enabled EPS enabled Ethanol ECT cranking compensation Ethanol fuel compensation Ethanol ignition compensation Ethanol ignition multiplier Ethanol input enabled(Off=0,On=15) Ethanol input enabled(Off=0,On=60) Ethanol percentage EVAP FTP enabled (P0451 P0452 P0453 P1454) EVAP FTP enabled(P0451 P0452 P0453 P1454) (RSSWGO91) EVAP leak detection enabled(P0455 P0456 P0457) EVAP VSV error check enabled(P0498 P0499) Flash alternator light when TC active Flash check engine for knock enabled Flash check engine for TC Forced induction enabled Fuel high #1 Fuel high #2 Fuel high #3 Fuel high #4 Fuel high #5 Fuel low #1 Fuel low #2 Fuel low #3 Fuel low #4 Fuel low #5 Fuel Pressure Full throttle shift enabled Full throttle shift minimum throttle Full throttle shift rpm limit Gear ignition compensation Idle fuel table rpm low Ignition dwell angle voltage compensation Ignition high #1 Ignition high #2 Ignition high #3 Ignition high #4 Ignition high #5 Ignition IAT retard applied to ignition advance Ignition low #1 Ignition low #2 Ignition low #3 Ignition low #4 Ignition low #5 Ignition retard gear compensation Ignition retard throttle compensation Immobilizer enabled(Off=0) Injector phase (warm up) Injector size Knock ignition limit high #1 Knock ignition limit high #2 Knock ignition limit high #3 Knock ignition limit high #4 Knock ignition limit high #5 Knock ignition limit low #1 Knock ignition limit low #2 Knock ignition limit low #3 Knock ignition limit low #4 Knock ignition limit low #5 Knock retard high Knock retard low Knock sensitivity high #1 Knock sensitivity high #2 Knock sensitivity high cylinder 1-2 Knock sensitivity high cylinder 3-4 Knock sensitivity high Knock sensitivity low #1 Knock sensitivity low #2 Knock sensitivity low cylinder 1-2 Knock sensitivity low cylinder 3-4 Knock sensitivity low Knock sensor enabled Lambda target (closed loop) Lambda target (open loop) Launch min rpm for ign retard and fuel enrichment Launch rpm (adjustable) Launch rpm additional fuel Launch rpm ign retard MAP offset MAP scalar MAP too low / too high enabled(P1127 P1128) Mass or volume circuit range performance problem enabled(P0101) Maximum cam angle delta Maximum change Maximum ECT Maximum gear Maximum IAT Maximum lambda Maximum load delta Maximum load Maximum plate deviation (P2101) Maximum rpm delta Maximum rpm Maximum TPS Maximum VTC Minimum ECT for alternator control Minimum gear Minimum IAT Minimum lambda Minimum load Minimum pressure for speed/density Minimum rpm Minimum TPS Minimum VTC Misfire detection enabled Mode 6 CVN OBD MODE $01 PID $1C value | RSOBDREQ enabled OBD region (0 OBD region(0) | RSSWOBDCH enabled OBDII mode 6 support(Off=0,On=255) OBDII mode 9 support(Off=0,On=255) Open loop Overall fuel trim Overrev rpm Overrun cutoff MAP high cam hys high Overrun cutoff MAP high cam hys low Overrun cutoff MAP low cam hys high Overrun cutoff MAP low cam hys low Overrun fuel cut delay P0420 Malfunction Threshold P2263 boost problem enabled #1 P2263 boost problem enabled #2 P2263 boost problem enabled #3 P2263 boost problem enabled #4 P2263 boost problem enabled #5 PA sensor enabled PA vs MAP error enabled (P2227) PA vs MAP error enabled(P2227) Pit lane speed limit enabled Pit lane speed limit speed Primary oxygen sensor enabled Purge/EVAP enabled Radiator fan off Readiness codes enabled RSFIECUID5 enabled RSSWENGOILLIFE enabled RSSWGO00AB enabled RSSWGO13C enabled RSSWGO14B enabled RSSWGO45 enabled RSSWGO48S enabled RSSWGO61AC enabled RSSWGO61AC RSSWGO61E enabled RSSWGO63BL enabled RSSWGO63BR enabled RSSWGO63D enabled RSSWGO67 enabled RSSWGOF121 enabled Second ECT sensor enabled Secondary intake runner low rpm error enabled (P1077) Secondary oxygen sensor enabled SWM9VINOUT SWMFPTN System control register 1 Target lambda high Target lambda low Throttle flow vs opening Tip in fuel throttle compensation TPlate Normal Traction Control ignition retard value Traction control input(Off=0,On=4) Traction control input(Off=0,On=52) Traction control input(Off=0,On=6) Traction control minimum rpm Traction control voltage offset Tuning method Unknown DTC #1 enabled Unknown DTC #10 enabled Unknown DTC #11 enabled Unknown DTC #12 enabled Unknown DTC #13 enabled Unknown DTC #14 enabled Unknown DTC #15 enabled Unknown DTC #16 enabled Unknown DTC #17 enabled Unknown DTC #18 enabled Unknown DTC #19 enabled Unknown DTC #2 enabled Unknown DTC #20 enabled Unknown DTC #21 enabled Unknown DTC #22 enabled Unknown DTC #23 enabled Unknown DTC #24 enabled Unknown DTC #25 enabled Unknown DTC #26 enabled Unknown DTC #27 enabled Unknown DTC #28 enabled Unknown DTC #29 enabled Unknown DTC #3 enabled Unknown DTC #30 enabled Unknown DTC #31 enabled Unknown DTC #32 enabled Unknown DTC #34 enabled Unknown DTC #35 enabled Unknown DTC #36 enabled Unknown DTC #4 enabled Unknown DTC #5 enabled Unknown DTC #6 enabled Unknown DTC #7 enabled Unknown DTC #8 enabled Unknown DTC #9 enabled Unkonwn sensor #1 enabled Unkonwn sensor #2 enabled Unkonwn sensor #3 enabled Unkonwn sensor #4 enabled Unkonwn sensor #5 enabled Unkonwn sensor #6 enabled Update frequency Use corrected wideband Use fuel trims Use MAP fuel tables Use MAP to determine WOT(Off=1,On=0) Use speed/density (MAP) fuel tables VSA enabled VTC base duty cycle VTC enabled VTEC oil pressure switch enabled Water temperature fuel compensation cranking Water temperature fuel compensation high Wideband input(Off=0,On=12) Wideband input(Off=0,On=14) Wideband input(Off=0,On=4) Wideband input(Off=0,On=52) Wideband lambda Wideband voltage input(Off=0,On=14) Wideband voltage offset WOT lambda adjustment high #1 WOT lambda adjustment high #2 WOT lambda adjustment high #3 WOT lambda adjustment low #1 WOT lambda adjustment low #2 WOT lambda adjustment low #3