--- name: ieee-transactions-on-robotics description: Use when targeting IEEE Transactions on Robotics (T-RO) or deciding whether a robotics manuscript fits this venue. Encodes the journal's fit, the complete-and-experimentally-validated-contribution bar, real-robot evidence rigor, the T-RO-vs-IJRR routing, house style, official-submission re-check, and desk-reject heuristics. --- # IEEE Transactions on Robotics (ieee-transactions-on-robotics) ## Journal positioning IEEE Transactions on Robotics (T-RO), published jointly by the IEEE Robotics and Automation Society and partnering societies, is a flagship archival venue for **complete, rigorously validated robotics contributions**: manipulation, locomotion, motion planning, control, perception-for-action, estimation, and mechanism/system design. The defining expectation is a self-contained advance demonstrated through **experiments on real robots or high-fidelity simulation**, with quantitative evaluation — not a preliminary idea or a method shown only on a toy. Compared with its sibling `the-international-journal-of-robotics-research`, T-RO favors complete, well-validated results, while IJRR leans to longer, conceptually framed archival treatments; route by depth-of-framing vs. completeness-of-validation. This skill is a **fit / venue-selection / re-framing** tool. It does not replace the journal's current official author information. Before submitting, re-check the live IEEE T-RO author guidance and submission system. ## When to trigger - The author names T-RO for a manipulation, locomotion, planning, control, or perception-for-action manuscript and wants a fit/framing check. - A result must be re-framed from "a method that works in simulation" into a complete contribution with real-robot or high-fidelity experimental validation. - The author is choosing between T-RO and `the-international-journal-of-robotics-research`, or between T-RO and a conference-paper extension. - The author needs T-RO's experimental-validation bar and desk-reject heuristics. ## Scope & topic fit - Manipulation and grasping: dexterous and contact-rich manipulation, planning and control of manipulators, tactile/force-based interaction. - Legged, wheeled, aerial, and underwater locomotion: dynamics, gait, and control demonstrated on physical platforms or validated high-fidelity simulation. - Motion and task planning: sampling-based, optimization-based, and learning-based planning with analysis and demonstrated performance. - Robot control and estimation: whole-body control, state estimation, SLAM-for-control, and learning-based control with real-system evaluation. - Perception for action: closing the loop from sensing to robot behavior, where the robotics contribution (not the vision algorithm alone) is central. - Mechanism, actuator, and system design: novel robot designs validated by characterization and task demonstration. ## Method & evidence bar - **Experiments on real robots** are the norm; high-fidelity simulation is acceptable when justified, but pure toy simulation rarely clears the bar. - Evaluation must be quantitative and statistically meaningful: report trials, success rates, error metrics, and timing, with appropriate baselines. - The contribution must be complete — formulation, method, analysis (where relevant), and a convincing experimental campaign — not a preliminary proof-of-concept. - Compare against the closest robotics baselines under matched conditions; ablate to show which component drives the gain. - For learning-based methods, address sim-to-real transfer, generalization, and robustness, not just one trained instance on one setup. - Provide reproducibility detail: platform, parameters, and ideally a supplementary video and code/data per current policy. ## Structure & house style - IEEE double-column format; T-RO publishes full-length **Papers** (substantial, archival) — match the contribution to that scope and re-check current article types and length policy on the live guide. - The introduction frames the robotics problem and the gap, then states the complete contribution; conference-to-journal extensions must add substantial new content. - Figures are load-bearing: system/method diagrams, experimental setups, result plots with error bars, and frames from the accompanying video. - A thorough experimental-results section is central; tables summarize quantitative comparisons across baselines and conditions. - A supplementary video is strongly expected for hardware results. ## Official-submission checklist - Before giving submission-ready advice, read `../../resources/source-basis.md` and `../../resources/official-source-map.md`; start from the IEEE Author Center anchors, then cite the current T-RO-specific page you checked. - Search the live site for "IEEE Transactions on Robotics information for authors" and follow the current ScholarOne/IEEE version. - Re-check article types, page/length limits and overlength policy, and the IEEE double-column template. - Confirm video, code/data, and reproducibility submission requirements. - Re-check ORCID, competing-interests, funding, author-contribution, and AI-use disclosure requirements, and IEEE open-access options. - If the live official instructions conflict with this skill, the official instructions win. ## Pre-submission self-check - [ ] The contribution is a complete robotics advance, not a preliminary idea or single toy demo. - [ ] Validation is on real robots (or justified high-fidelity simulation) with quantitative metrics. - [ ] Results report trials/success rates/errors with appropriate baselines and ablations. - [ ] Learning-based claims address transfer, generalization, and robustness beyond one setup. - [ ] Any conference precursor is substantially extended with new content. - [ ] A supplementary video and reproducibility detail accompany hardware results; length fits current limits. ## Common desk-reject triggers - Method shown only in toy simulation with no real-robot or high-fidelity validation. - Preliminary proof-of-concept lacking a complete formulation, analysis, or convincing experiments. - Incremental conference extension with little new content beyond the prior paper. - A computer-vision or learning paper with a robot used only as a label, no robotics contribution. - Quantitative evaluation without baselines, trials, or statistics; cherry-picked single runs. ## Re-routing decision - Longer, conceptually framed, foundational archival robotics → `the-international-journal-of-robotics-research`. - Control-theoretic result with guarantees as the core → `ieee-transactions-on-automatic-control` / `automatica`. - Industrial robot deployment with hardware-system focus → `ieee-transactions-on-industrial-electronics`. - Medical/surgical-robotics imaging contribution → `ieee-transactions-on-medical-imaging` / `ieee-transactions-on-biomedical-engineering`. - Focused, timely result → a robotics letters venue or conference. ## Output format ```text [Fit] High / Medium / Low (one-line reason) [Target] IEEE Transactions on Robotics [Topic tags] <2–3 closest robotics subtopics> [Contribution] [Method/evidence] [Top risk] [Article type] Paper [Official items to re-check]
[Re-route suggestion] ```