{ "document": { "acknowledgments": [ { "names": [ "Ivan Sanchez" ], "summary": "reporting this vulnerability" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Vendor: Rockwell Automation", "title": "Risk evaluation" }, { "category": "other", "text": "Commercial Facilities, Defense Industrial Base, Energy, and Government Facilities", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Globally", "title": "Countries/areas deployed" }, { "category": "other", "text": "Milwaukee, Wisconsin", "title": "Company headquarters location" }, { "category": "general", "text": "ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the ICS -CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability. Not remotely exploitable. High skill level is needed to exploit.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-17-047-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-047-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-047-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-047-01" } ], "title": "Rockwell Automation Connected Components Workbench", "tracking": { "current_release_date": "2017-03-21T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-047-01", "initial_release_date": "2017-02-16T00:00:00.000000Z", "revision_history": [ { "date": "2017-02-16T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-17-047-01P Rockwell Automation Connected Components Workbench" }, { "date": "2017-03-21T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-17-047-01 Rockwell Automation Connected Components Workbench (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "<= 9.01.00", "product": { "name": "Connected Components Workbench - Developer Edition 9328-CCWDEVDEE: v9.01.00 and earlier", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Connected Components Workbench - Developer Edition 9328-CCWDEVDEE" }, { "branches": [ { "category": "product_version_range", "name": "<= 9.01.00", "product": { "name": "Connected Components Workbench - Developer Edition 9328-CCWDEVITE: v9.01.00 and earlier", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Connected Components Workbench - Developer Edition 9328-CCWDEVITE" }, { "branches": [ { "category": "product_version_range", "name": "<= 9.01.00", "product": { "name": "Connected Components Workbench - Developer Edition 9328-CCWDEVESE: v9.01.00 and earlier", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Connected Components Workbench - Developer Edition 9328-CCWDEVESE" }, { "branches": [ { "category": "product_version_range", "name": "<= 9.01.00", "product": { "name": "Connected Components Workbench - Developer Edition 9328-CCWDEVZHE: v9.01.00 and earlier", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Connected Components Workbench - Developer Edition 9328-CCWDEVZHE" }, { "branches": [ { "category": "product_version_range", "name": "<= 9.01.00", "product": { "name": "Connected Components Workbench - Free Standard Edition (All Supported Languages): v9.01.00 and earlier", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "Connected Components Workbench - Free Standard Edition (All Supported Languages)" }, { "branches": [ { "category": "product_version_range", "name": "<= 9.01.00", "product": { "name": "Connected Components Workbench - Developer Edition 9328-CCWDEVFRE: v9.01.00 and earlier", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "Connected Components Workbench - Developer Edition 9328-CCWDEVFRE" }, { "branches": [ { "category": "product_version_range", "name": "<= 9.01.00", "product": { "name": "Connected Components Workbench - Developer Edition 9328-CCWDEVENE: v9.01.00 and earlier", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "Connected Components Workbench - Developer Edition 9328-CCWDEVENE" }, { "branches": [ { "category": "product_version_range", "name": "<= 9.01.00", "product": { "name": "Connected Components Workbench - Developer Edition 9328-CCWDEVPTE: v9.01.00 and earlier", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "Connected Components Workbench - Developer Edition 9328-CCWDEVPTE" } ], "category": "vendor", "name": "Rockwell Automation" } ] }, "vulnerabilities": [ { "cve": "CVE-2017-5176", "cwe": { "id": "CWE-427", "name": "Uncontrolled Search Path Element" }, "notes": [ { "category": "summary", "text": "Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim 's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges.CVE-2017-5176 has been assigned to this vulnerability. A CVSS v3 base score of 7.0 has been assigned; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-5176" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Rockwell Automation has released a new version of Connected Components Workbench, Version 10.00 and Version 10.01 (All supported languages) which addresses the identified vulnerability.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Rockwell Automation recommends updating to the latest version of Connected Components Workbench, Version 10.00 or later", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "http://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112&refSoft=1&toggleState=&versions=55834,55972" }, { "category": "mitigation", "details": "For more information on this vulnerability and more detailed mitigation instructions, please see Rockwell Automation advisory labeled Connected Components Workbench Software Dynamic Link Library (DLL) Hijack Version 1.0, February 16, 2017", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1030688" } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ] } ] }