{ "document": { "acknowledgments": [ { "names": [ "Ilya Karpov" ], "organization": "Positive Technologies", "summary": "reporting these vulnerabilities to Schneider Electric" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "ATTENTION: Low skill level to exploit.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing, Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "France", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the ICS -CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-17-187-05 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-187-05.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-187-05 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-187-05" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-187-05" } ], "title": "Schneider Electric Ampla MES", "tracking": { "current_release_date": "2017-07-06T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-187-05", "initial_release_date": "2017-07-06T00:00:00.000000Z", "revision_history": [ { "date": "2017-07-06T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-17-187-05 Schneider Electric Ampla MES" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "<= 6.4", "product": { "name": "Ampla MES: versions 6.4 and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Ampla MES" } ], "category": "vendor", "name": "Schneider Electric Software, LLC" } ] }, "vulnerabilities": [ { "cve": "CVE-2017-9637", "cwe": { "id": "CWE-319", "name": "Cleartext Transmission of Sensitive Information" }, "notes": [ { "category": "summary", "text": "Ampla MES provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string.Note that when the third party database connectivity is configured with Windows Integrated Security as opposed to SQL username and password, the software is not vulnerable.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-9637" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. Software updates can be downloaded from Schneider Electric's Ampla Support “Shopping Kiosk” area or from the link below:", "product_ids": [ "CSAFPID-0001" ], "url": "http://shoppingkiosk.schneider-electric.com/doc_info.aspx?DocRef=Ampla2016R1Software&isdvd=False&df=12&gid=411131" }, { "category": "mitigation", "details": "For more information, users of affected products can read Schneider Electric's Ampla Security Bulletin LFSEC00000118 at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000118/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2017-9635", "cwe": { "id": "CWE-326", "name": "Inadequate Encryption Strength" }, "notes": [ { "category": "summary", "text": "Ampla MES provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user 's password.CVE-2017-9637 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-9635" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. Software updates can be downloaded from Schneider Electric's Ampla Support “Shopping Kiosk” area or from the link below:", "product_ids": [ "CSAFPID-0001" ], "url": "http://shoppingkiosk.schneider-electric.com/doc_info.aspx?DocRef=Ampla2016R1Software&isdvd=False&df=12&gid=411131" }, { "category": "mitigation", "details": "For more information, users of affected products can read Schneider Electric's Ampla Security Bulletin LFSEC00000118 at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000118/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.2, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }