{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "CISAservicedesk@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSMA-17-082-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsma-17-082-02.json" }, { "category": "self", "summary": "ICS Advisory ICSMA-17-082-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-17-082-02" } ], "title": "ICSMA-17-082-02_B. Braun Medical SpaceCom Open Redirect Vulnerability", "tracking": { "current_release_date": "2017-05-23T00:00:00.000000Z", "generator": { "engine": { "name": "CISA USCert CSAF Generator", "version": "1" } }, "id": "ICSMA-17-082-02", "initial_release_date": "2017-03-23T00:00:00.000000Z", "revision_history": [ { "date": "2017-03-23T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSMA-17-082-02P B. Braun Medical SpaceCom Open Redirect Vulnerability" }, { "date": "2017-05-23T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSMA-17-082-02 B. Braun Medical SpaceCom Open Redirect Vulnerability (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "< 012U000040", "product": { "name": "SpaceStation with SpaceCom module (integrated as part number 8713142U): software versions prior to Version 012U000040", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SpaceStation with SpaceCom module (integrated as part number 8713142U)" }, { "branches": [ { "category": "product_version_range", "name": "< 012U000040", "product": { "name": "SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U): software versions prior to Version 012U000040", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U)" } ], "category": "vendor", "name": "B. Braun" } ] }, "vulnerabilities": [ { "cve": "CVE-2017-6018", "cwe": { "id": "CWE-601", "name": "URL Redirection to Untrusted Site ('Open Redirect')" }, "notes": [ { "category": "summary", "text": "The web server of the affected product accepts untrusted input which could allow attackers to redirect the request to an unintended URL contained within untrusted input.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "https://ftp.bbmus.com", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://ftp.bbmus.com" } ], "scores": [ { "cvss_v3": { "baseScore": 5.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2017-6018" } ] }