{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "CISAservicedesk@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSMA-17-292-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsma-17-292-01.json" }, { "category": "self", "summary": "ICS Advisory ICSMA-17-292-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-17-292-01" } ], "title": "ICSMA-17-292-01_Boston Scientific ZOOM LATITUDE PRM Vulnerabilities", "tracking": { "current_release_date": "2017-10-19T00:00:00.000000Z", "generator": { "engine": { "name": "CISA USCert CSAF Generator", "version": "1" } }, "id": "ICSMA-17-292-01", "initial_release_date": "2017-10-19T00:00:00.000000Z", "revision_history": [ { "date": "2017-10-19T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSMA-17-292-01 Boston Scientific Zoom Latitude PRM Vulnerabilities" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "ZOOM LATITUDE Programmer/Recorder/Monitor (PRM) - Model 3120: all versions", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "ZOOM LATITUDE Programmer/Recorder/Monitor (PRM) - Model 3120" } ], "category": "vendor", "name": "Boston Scientific" } ] }, "vulnerabilities": [ { "cve": "CVE-2017-14014", "cwe": { "id": "CWE-321", "name": "Use of Hard-coded Cryptographic Key" }, "notes": [ { "category": "summary", "text": "The affected device uses a hard-coded cryptographic key to encrypt PHI prior to having it transferred to removable media.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Boston Scientific will not be issuing a product update to address the identified vulnerabilities in the ZOOM LATITUDE PRM - Model 3120. Boston Scientific has identified compensating controls to reduce the risk of exploitation and recommends that users implement the following measures:", "product_ids": [ "CSAFPID-0001" ], "url": "http://ics-cert.us-cert.gov/content/recommended-practices" } ], "scores": [ { "cvss_v3": { "baseScore": 4.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2017-14014" }, { "cve": "CVE-2017-14012", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "The affected device does not encrypt PHI at rest.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Boston Scientific will not be issuing a product update to address the identified vulnerabilities in the ZOOM LATITUDE PRM - Model 3120. Boston Scientific has identified compensating controls to reduce the risk of exploitation and recommends that users implement the following measures:", "product_ids": [ "CSAFPID-0001" ], "url": "http://ics-cert.us-cert.gov/content/recommended-practices" } ], "scores": [ { "cvss_v3": { "baseScore": 4.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2017-14012" } ] }