{ "document": { "acknowledgments": [ { "names": [ "ADLab" ], "organization": "Venustech", "summary": "reporting this vulnerability to NCCIC" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Vendor: Schneider Electric", "title": "Risk evaluation" }, { "category": "other", "text": "Critical manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "France", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerabilityby protecting themselves from social engineering attacks. Specifically, users should: Do not click web links or open unsolicited attachments in email messages; Refer to Recognizing and Avoiding Email Scams (https://www.cisa.gov/reading_room/emailscams_0905.pdf) for more information on avoiding email scams; Refer to Avoiding Social Engineering and Phishing Attacks (https://www.cisa.gov/cas/tips/ST04-014.html) for more information on social engineering attacks.", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the NCCIC Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT website.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely. Low skill level is needed to exploit.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-18-065-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsa-18-065-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-18-065-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-065-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/" } ], "title": "Schneider Electric SoMove Software and DTM Software Components", "tracking": { "current_release_date": "2018-03-06T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-18-065-02", "initial_release_date": "2018-03-06T00:00:00.000000Z", "revision_history": [ { "date": "2018-03-06T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-18-065-02 Schneider Electric SoMove Software and DTM Software Components" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "< 1.8.0", "product": { "name": "ATV6xx DTM: versions prior to 1.8.0", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "ATV6xx DTM" }, { "branches": [ { "category": "product_version_range", "name": "< 1.2.3", "product": { "name": "ATV340 DTM: versions prior to 1.2.3", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "ATV340 DTM" }, { "branches": [ { "category": "product_version_range", "name": "< 12.7.0", "product": { "name": "ATV12 DTM: versions prior to 12.7.0", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "ATV12 DTM" }, { "branches": [ { "category": "product_version_range", "name": "< 12.7.0", "product": { "name": "ATV32 DTM: versions prior to 12.7.0", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "ATV32 DTM" }, { "branches": [ { "category": "product_version_range", "name": "< 1.1.6", "product": { "name": "ATV320 DTM: versions prior to 1.1.6", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "ATV320 DTM" }, { "branches": [ { "category": "product_version_range", "name": "< 12.7.0", "product": { "name": "ATV31/312 DTM: versions prior to 12.7.0", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "ATV31/312 DTM" }, { "branches": [ { "category": "product_version_range", "name": "< 12.7.0", "product": { "name": "AltivarDtmLibrary: versions prior to 12.7.0", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "AltivarDtmLibrary" }, { "branches": [ { "category": "product_version_range", "name": "< 1.3.5", "product": { "name": "ATV9xx DTM: versions prior to 1.3.5", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "ATV9xx DTM" }, { "branches": [ { "category": "product_version_range", "name": "< 12.7.0", "product": { "name": "ATV212 DTM: versions prior to 12.7.0", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "ATV212 DTM" }, { "branches": [ { "category": "product_version_range", "name": "< 12.7.0", "product": { "name": "ATV71 DTM: versions prior to 12.7.0", "product_id": "CSAFPID-00010" } } ], "category": "product_name", "name": "ATV71 DTM" }, { "branches": [ { "category": "product_version_range", "name": "< 12.7.0", "product": { "name": "ATV61 DTM: versions prior to 12.7.0", "product_id": "CSAFPID-00011" } } ], "category": "product_name", "name": "ATV61 DTM" }, { "branches": [ { "category": "product_version_range", "name": "< 12.7.0", "product": { "name": "ATV LIFT DTM: versions prior to 12.7.0", "product_id": "CSAFPID-00012" } } ], "category": "product_name", "name": "ATV LIFT DTM" }, { "branches": [ { "category": "product_version_range", "name": "< 2.6.2", "product": { "name": "SoMove software: versions prior to 2.6.2", "product_id": "CSAFPID-00013" } } ], "category": "product_name", "name": "SoMove software" } ], "category": "vendor", "name": "Schneider Electric Software, LLC" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-7239", "cwe": { "id": "CWE-427", "name": "Uncontrolled Search Path Element" }, "notes": [ { "category": "summary", "text": "An attacker may execute malicious DLL files that have been placed within the search path. CVE-2018-7239 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7239" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "SoMove Software—SoMove_V2.6.3", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.schneider-electric.com/en/download/document/SoMove_FDT/" }, { "category": "vendor_fix", "details": "ATV320 DTM—Schneider_Electric_Altivar_Machine_ATV320_DTM_Library_V1.1.6", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.schneider-electric.com/en/download/document/ATV320_DTM_Library/" }, { "category": "vendor_fix", "details": "ATV340 DTM—Schneider_Electric_Altivar_Machine_ATV340_DTM_Library_V1.2.3", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.schneider-electric.com/en/download/document/ATV340_DTM_LibraryEN/" }, { "category": "vendor_fix", "details": "ATV6XX DTM—Schneider_Electric_Altivar_Process_ATV6xx_DTM_Library_V1.8.0", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.schneider-electric.com/en/download/document/ATV6xx_DTM_Library_EN/" }, { "category": "vendor_fix", "details": "ATV9XX DTM—Schneider-Electric-Altivar-Process-ATV9xx-DTM-Library-V1.3.5", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.schneider-electric.com/en/download/document/ATV9xx_DTM_Library_EN/" }, { "category": "vendor_fix", "details": "ATV32 / ATV71 / ATV61 / ATV LIFT / ATV31_312 / ATV212 / ATV12 AltivarDtmLibraryV12.7.0", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.schneider-electric.com/en/download/document/Altivar_DTM_Library/" }, { "category": "mitigation", "details": "For more information on this vulnerability and its associated patches, please see Schneider Electric's security notification SEVD-2018-060-01 on their website", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/" }, { "category": "mitigation", "details": "For further information related to cybersecurity in Schneider Electric products, please visit the company's cybersecurity web page", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] } ] }