{ "document": { "acknowledgments": [ { "names": [ "Dan Regalado" ], "organization": "Zingbox", "summary": "reporting this vulnerability to NCCIC" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow an attacker to obtain technical information about the Metasys or BCPro server, allowing an attacker to target a system for attack.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Milwaukee, Wisconsin", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-18-212-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsa-18-212-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-18-212-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-212-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Johnson Controls Metasys and BCPro", "tracking": { "current_release_date": "2018-07-31T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-18-212-02", "initial_release_date": "2018-07-31T00:00:00.000000Z", "revision_history": [ { "date": "2018-07-31T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-18-212-02 Johnson Controls Metasys and BCPro" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "< 3.0.2", "product": { "name": "BCPro (BCM): all versions prior to 3.0.2", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "BCPro (BCM)" }, { "branches": [ { "category": "product_version_range", "name": "<= 8.0", "product": { "name": "Metasys System: Versions 8.0 and prior", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Metasys System" } ], "category": "vendor", "name": "Johnson Controls Inc" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-10624", "cwe": { "id": "CWE-209", "name": "Generation of Error Message Containing Sensitive Information" }, "notes": [ { "category": "summary", "text": "This vulnerability results from improper error handling in HTTP-based communications with the server, which could allow an attacker to obtain technical information.CVE-2018-10624 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-10624" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "This issue was remediated in Metasys v8.1 (April, 2016). Users should upgrade to the latest product version (9.0). For Metasys information, contact your Metasys field service/sales representative.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "This issue was remediated in the BCPro Workstation in BCPro v3.0 (October, 2017) and mitigated for the BACnet Router and Gateway in BCPro v3.0.2 (June, 2018). Users should upgrade to the latest product versions. For more BCPro information, contact your BCPro sales and support representative.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Product security contact information, Building Automation System hardening, and security resources are located at our product security website http://www.johnsoncontrols.com/buildings/specialty-pages/product-security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://www.johnsoncontrols.com/buildings/specialty-pages/product-security" }, { "category": "mitigation", "details": "Contact information: Johnson Controls Global Product Security at productsecurity@jci.com", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://mailto:productsecurity@jci.com" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] } ] }