{ "document": { "acknowledgments": [ { "names": [ "Ariele Caltabiano (kimiya)" ], "organization": "9SG Security Team", "summary": "reporting these vulnerabilities to NCCIC" }, { "names": [ "Mat Powell" ], "organization": "Trend Micro 's Zero Day Initiative (ZDI)", "summary": "reporting these vulnerabilities to NCCIC" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could crash the accessed device, resulting in a buffer overflow condition that may allow remote code execution.", "title": "Risk evaluation" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Taiwan", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC also recommends that users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-18-284-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsa-18-284-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-18-284-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-284-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-284-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Delta Industrial Automation TPEditor", "tracking": { "current_release_date": "2018-10-11T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-18-284-03", "initial_release_date": "2018-10-11T00:00:00.000000Z", "revision_history": [ { "date": "2018-10-11T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-18-284-03 Delta Industrial Automation TPEditor" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "<= 1.90", "product": { "name": "TPEditor: Versions 1.90 and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "TPEditor" } ], "category": "vendor", "name": "Delta Electronics" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-17929", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files lacking user input validation before copying data from project files onto the stack and may allow an attacker to remotely execute arbitrary code.CVE-2018-17929 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-17929" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Delta Electronics recommends affected users update to the latest version of Delta Industrial Automation TPEditor, Version 1.91, which is available for download at: http://www.deltaww.com/Products/PluginWebUserControl/downloadCenterCounter.aspx?DID=4536&DocPath=1&hl=en-US.", "product_ids": [ "CSAFPID-0001" ], "url": "https://urldefense.proofpoint.com/v2/url?u=http-3A__www.deltaww.com_Products_PluginWebUserControl_downloadCenterCounter.aspx-3FDID-3D4536-26DocPath-3D1-26hl-3Den-2DUS&d=DwMFbw&c=54IZrppPQZKX9mLzcGdPfFD1hxrcB__aEkJFOKJFd00&r=zE5lG3CZZIbdBvT6slVAzQ&m=eE2DBvGNl7BnFfhTKbETdjQV2y9zb8THHT0gnf6sZrE&s=fYoJ-JCHTBnxhOyFR1shnEDMpDGsyMEuU5PfG07_mPA&e=" }, { "category": "mitigation", "details": "Delta Electronics also recommends affected users restrict the interaction with the application to trusted files.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-17927", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Multiple out-of-bounds write vulnerabilities may be exploited by processing specially crafted project files lacking user input validation, which may cause the system to write outside the intended buffer area and may allow remote code execution.CVE-2018-17927 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-17927" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Delta Electronics recommends affected users update to the latest version of Delta Industrial Automation TPEditor, Version 1.91, which is available for download at: http://www.deltaww.com/Products/PluginWebUserControl/downloadCenterCounter.aspx?DID=4536&DocPath=1&hl=en-US.", "product_ids": [ "CSAFPID-0001" ], "url": "https://urldefense.proofpoint.com/v2/url?u=http-3A__www.deltaww.com_Products_PluginWebUserControl_downloadCenterCounter.aspx-3FDID-3D4536-26DocPath-3D1-26hl-3Den-2DUS&d=DwMFbw&c=54IZrppPQZKX9mLzcGdPfFD1hxrcB__aEkJFOKJFd00&r=zE5lG3CZZIbdBvT6slVAzQ&m=eE2DBvGNl7BnFfhTKbETdjQV2y9zb8THHT0gnf6sZrE&s=fYoJ-JCHTBnxhOyFR1shnEDMpDGsyMEuU5PfG07_mPA&e=" }, { "category": "mitigation", "details": "Delta Electronics also recommends affected users restrict the interaction with the application to trusted files.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }