{ "document": { "acknowledgments": [ { "names": [ "Ismail Bulbul" ], "summary": "reporting this vulnerability to NCCIC" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow an attacker to execute JavaScript on the victim 's browser.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Europe", "title": "Countries/areas deployed" }, { "category": "other", "text": "Switzerland", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC also recommends that users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-18-338-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsa-18-338-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-18-338-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-338-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-338-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "SpiderControl SCADA WebServer", "tracking": { "current_release_date": "2018-12-04T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-18-338-02", "initial_release_date": "2018-12-04T00:00:00.000000Z", "revision_history": [ { "date": "2018-12-04T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-18-338-02 SpiderControl SCADA WebServer" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "< 2.03.0001", "product": { "name": "SCADA WebServer: versions prior to 2.03.0001", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SCADA WebServer" } ], "category": "vendor", "name": "SpiderControl" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-18991", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" }, "notes": [ { "category": "summary", "text": "Reflected cross-site scripting (non-persistent) could allow an attacker to send a crafted URL that contains JavaScript, which can be reflected off the web application to the victim 's browser. CVE-2018-18991 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-18991" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "SpiderControl has released Version 2.03.0001, which fixes the vulnerability. The update can be found here:", "product_ids": [ "CSAFPID-0001" ], "url": "http://spidercontrol.net/download/downloadarea/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }