{ "document": { "acknowledgments": [ { "names": [ "Billy Rios", "Jesse Young", "Jonathan Butts" ], "organization": "Whitescope LLC", "summary": "reporting these vulnerabilities to NCCIC" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities may allow an attacker with physical access to obtain per-product credentials that are utilized to authenticate data uploads and encrypt data at rest. Additionally, an attacker with access to a set of these credentials and additional identifiers can upload invalid data to the Medtronic CareLink network.", "title": "Risk evaluation" }, { "category": "other", "text": "Healthcare and Public Health", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Ireland", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely. High skill level is needed to exploit.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSMA-18-219-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsma-18-219-01.json" }, { "category": "self", "summary": "ICS Advisory ICSMA-18-219-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-18-219-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Medtronic MyCareLink 24950 Patient Monitor", "tracking": { "current_release_date": "2018-08-07T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSMA-18-219-01", "initial_release_date": "2018-08-07T00:00:00.000000Z", "revision_history": [ { "date": "2018-08-07T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSMA-18-219-01 Medtronic MyCareLink 24950 Patient Monitor" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "24950 MyCareLink Monitor: all versions", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "24950 MyCareLink Monitor" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "24952 MyCareLink Monitor: all versions", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "24952 MyCareLink Monitor" } ], "category": "vendor", "name": "Medtronic" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-10626", "cwe": { "id": "CWE-345", "name": "Insufficient Verification of Data Authenticity" }, "notes": [ { "category": "summary", "text": "The affected product 's update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.CVE-2018-10626 has been assigned to this vulnerability. A CVSS v3 base score of 4.4 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-10626" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Medtronic has made server-side updates to address the insufficient verification vulnerability identified in this advisory. Medtronic is implementing additional server-side mitigations to enhance data integrity and authenticity.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Medtronic recommends users take additional defensive measures to minimize the risk of exploitation. Specifically, users should:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Medtronic has released additional patient focused information, at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "https://www.medtronic.com/security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.medtronic.com/security" } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2018-10622", "cwe": { "id": "CWE-257", "name": "Storing Passwords in a Recoverable Format" }, "notes": [ { "category": "summary", "text": "The affected products use per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication and encryption of local data at rest.CVE-2018-10622 has been assigned to this vulnerability. A CVSS v3 base score of 4.9 has been calculated; the CVSS vector string is (AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-10622" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Medtronic has made server-side updates to address the insufficient verification vulnerability identified in this advisory. Medtronic is implementing additional server-side mitigations to enhance data integrity and authenticity.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Medtronic recommends users take additional defensive measures to minimize the risk of exploitation. Specifically, users should:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Medtronic has released additional patient focused information, at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "https://www.medtronic.com/security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.medtronic.com/security" } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] } ] }