{ "document": { "acknowledgments": [ { "names": [ "Ivan Sanchez" ], "organization": "NullCode", "summary": "reporting this vulnerability to NCCIC" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability may allow an attacker to execute arbitrary code, and cause a denial-of-service condition within the Text Editor application.", "title": "Risk evaluation" }, { "category": "other", "text": "Chemical, Critical Manufacturing, Dams, Energy, Food and Agriculture, Water and Wastewater", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Switzerland", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC also recommends that users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely. High skill level is needed to exploit.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-19-017-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-017-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-19-017-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-017-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-017-02" } ], "title": "ABB CP400 Panel Builder TextEditor 2.0", "tracking": { "current_release_date": "2019-01-17T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-017-02", "initial_release_date": "2019-01-17T00:00:00.000000Z", "revision_history": [ { "date": "2019-01-17T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-19-017-02 ABB CP400 Panel Builder TextEditor 2.0" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "<= 2.0.7.05", "product": { "name": "CP400PB Panel Builder for CP405 and CP408: Versions 2.0.7.05 and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "CP400PB Panel Builder for CP405 and CP408" } ], "category": "vendor", "name": "ABB" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-19008", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The application contains a vulnerability in the file parser of the Text Editor wherein the application doesn 't properly prevent the insertion of specially crafted files.CVE-2018-19008 has been assigned to this vulnerability. A CVSS v3 base score of 7.0 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19008" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "ABB recommends users of affected Versions 2.0.7.05 and prior update to the latest Version 2.1.7.21, which can be requested at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "https://new.abb.com/products/ABB1SAP500400R0001" }, { "category": "mitigation", "details": "For additional information, see the ABB advisory ABBVU-IACT-3BSE091042 at the following location:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "SECURITY - CP400 Panel Builder TextEditor 2.0, Improper input validation vulnerability ABBVU-IACT-3BSE091042", "product_ids": [ "CSAFPID-0001" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=3BSE091042&LanguageCode=en&DocumentPartId=&Action=Launch" }, { "category": "mitigation", "details": "Conduct or reinforce cybersecurity awareness training for users.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow general cybersecurity best practice recommendations for industrial control systems.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Be aware that it is possible to infect Panel Builder files with malware.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Be careful with files that are received unexpectedly and/or from unexpected sources.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Carefully inspect any files transferred between computers, scan them with up-to-date antivirus software, so that only legitimate files are transferred.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Manage user accounts following the principle of least privilege.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "More information on recommended practices can be found in ABB's Security for Industrial Automation and Control Systems paper - 3BSE032547.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }