{ "document": { "acknowledgments": [ { "names": [ "JunYoung Park" ], "summary": "reporting this vulnerability to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow for an attacker with access to PLC traffic to obtain user credentials.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-19-213-04 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-213-04.json" }, { "category": "self", "summary": "ICS Advisory ICSA-19-213-04 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-213-04" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "3S-Smart Software Solutions GmbH CODESYS V3 (Update A)", "tracking": { "current_release_date": "2020-05-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-213-04", "initial_release_date": "2019-08-01T00:00:00.000000Z", "revision_history": [ { "date": "2019-08-01T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-19-213-04 3S-Smart Software Solutions GmbH CODESYS V3" }, { "date": "2020-05-14T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-19-213-04 3S-Smart Software Solutions GmbH CODESYS V3 (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "CODESYS Control for PFC200 containing the CmpUserMgr component: all versions", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "CODESYS Control for PFC200 containing the CmpUserMgr component" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "CODESYS Control Win V3 (also part of the CODESYS Development System setup) containing the CmpUserMgr component: all versions", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "CODESYS Control Win V3 (also part of the CODESYS Development System setup) containing the CmpUserMgr component" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "CODESYS Control RTE V3 (for Beckhoff CX) containing the CmpUserMgr component: all versions", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "CODESYS Control RTE V3 (for Beckhoff CX) containing the CmpUserMgr component" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "CODESYS V3 Simulation Runtime (part of the CODESYS Development System) containing the CmpUserMgr component: all versions", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "CODESYS V3 Simulation Runtime (part of the CODESYS Development System) containing the CmpUserMgr component" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "CODESYS Control for Linux containing the CmpUserMgr component: all versions", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "CODESYS Control for Linux containing the CmpUserMgr component" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "CODESYS Control V3 Runtime System Toolkit containing the CmpUserMgr component: all versions", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "CODESYS Control V3 Runtime System Toolkit containing the CmpUserMgr component" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "CODESYS Control for IOT2000 containing the CmpUserMgr component: all versions", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "CODESYS Control for IOT2000 containing the CmpUserMgr component" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "CODESYS Control for BeagleBone containing the CmpUserMgr component: all versions", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "CODESYS Control for BeagleBone containing the CmpUserMgr component" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "CODESYS Control RTE V3 containing the CmpUserMgr component: all versions", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "CODESYS Control RTE V3 containing the CmpUserMgr component" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "CODESYS HMI V3 containing the CmpUserMgr component: all versions", "product_id": "CSAFPID-00010" } } ], "category": "product_name", "name": "CODESYS HMI V3 containing the CmpUserMgr component" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "CODESYS Control for emPC-A/iMX6 containing the CmpUserMgr component: all versions", "product_id": "CSAFPID-00011" } } ], "category": "product_name", "name": "CODESYS Control for emPC-A/iMX6 containing the CmpUserMgr component" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "CODESYS Control for Raspberry Pi containing the CmpUserMgr component: all versions", "product_id": "CSAFPID-00012" } } ], "category": "product_name", "name": "CODESYS Control for Raspberry Pi containing the CmpUserMgr component" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "CODESYS Control for PFC100 containing the CmpUserMgr component: all versions", "product_id": "CSAFPID-00013" } } ], "category": "product_name", "name": "CODESYS Control for PFC100 containing the CmpUserMgr component" } ], "category": "vendor", "name": "3S-Smart Software Solutions GmbH" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-9013", "cwe": { "id": "CWE-522", "name": "Insufficiently Protected Credentials" }, "notes": [ { "category": "summary", "text": "The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport.CVE-2019-9013 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-9013" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "3S-Smart Software Solutions GmbH reports this vulnerability will be corrected by downloading Version 3.5.16.0", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.codesys.com/download" }, { "category": "mitigation", "details": "For more information, please see the CODESYS V3 advisory 2019-08.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.codesys.com/security/security-reports.html" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] } ] }