{ "document": { "acknowledgments": [ { "names": [ "Francis Provencher (PRL)" ], "organization": "Trend Micro 's Zero Day Initiative", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to obtain confidential information or execute remote code.", "title": "Risk evaluation" }, { "category": "other", "text": "Chemical, Commercial Facilities, Energy, Food and Agriculture, Transportation Systems, Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "South America", "title": "Countries/areas deployed" }, { "category": "other", "text": "Brazil", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-19-213-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-213-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-19-213-06 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-213-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/cas/tips/ST04-014.html" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-213-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "LCDS LAquis SCADA LQS File Parsing", "tracking": { "current_release_date": "2019-08-01T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-213-06", "initial_release_date": "2019-08-01T00:00:00.000000Z", "revision_history": [ { "date": "2019-08-01T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-19-213-06 LCDS LAquis SCADA LQS File Parsing" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "4.3.1.71", "product": { "name": "SCADA: 4.3.1.71", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SCADA" } ], "category": "vendor", "name": "LCDS Leão Consultoria e Desenvolvimento de Sistemas LTDA ME" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-10994", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Processing a specially crafted project file may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information.CVE-2019-10994 has been assigned to this vulnerability. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-10994" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "LCDS recommends users update to Version 4.3.1.323", "product_ids": [ "CSAFPID-0001" ], "url": "https://laquisscada.com" } ], "scores": [ { "cvss_v3": { "baseScore": 2.5, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-10980", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type ('Type Confusion')" }, "notes": [ { "category": "summary", "text": "A type confusion vulnerability may be exploited when LAquis SCADA processes a specially crafted project file. This may allow an attacker to execute remote code.CVE-2019-10980 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-10980" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "LCDS recommends users update to Version 4.3.1.323", "product_ids": [ "CSAFPID-0001" ], "url": "https://laquisscada.com" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }