{ "document": { "acknowledgments": [ { "names": [ "Julian Speith", "Christof Paar" ], "organization": "Max Planck Institute for Security and Privacy", "summary": "coordinating this vulnerability with Siemens" }, { "names": [ "Florian Schweins", "Alexander May" ], "organization": "Ruhr University", "summary": "coordinating this vulnerability with Siemens" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow access to unencrypted data.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet; Locate control system networks and remote devices behind firewalls and isolate them from the business network; When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-350-13 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-350-13.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-350-13 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-350-13" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Questa and ModelSim", "tracking": { "current_release_date": "2021-12-16T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-350-13", "initial_release_date": "2021-12-16T00:00:00.000000Z", "revision_history": [ { "date": "2021-12-16T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-350-13 Siemens Questa and ModelSim" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "ModelSim Simulation: All Versions", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "ModelSim Simulation" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "Questa Simulation: All Versions", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Questa Simulation" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-42023", "cwe": { "id": "CWE-522", "name": "Insufficiently Protected Credentials" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable to insufficiently protected keys required for decrypting intellectual property data, which could allow an attacker to discover the keys and bypass the protection intended by IEEE 1735 standard. CVE-2021-42023 has been assigned to this vulnerability. A CVSS v3 base score of 9.0 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42023" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens recommends upgrading to the lastest version of the following product, login is required: ModelSim Simulation new releases.", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/en-US/product/852852093/" }, { "category": "vendor_fix", "details": "Siemens recommends upgrading to the lastest version of the following product, login is required: Questa Simulation new releases.", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/en-US/product/852852103/" }, { "category": "mitigation", "details": "Company-internal use of encrypted design IP data: Apply technical and procedural measures to ensure access to the data is granted on a need-to-know basis.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Companies that deliver encrypted design IP data to their customers: Ensure procedural and contractual measures are in place that minimize the risk of unauthorized access to the data.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.0, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] } ] }