{ "document": { "acknowledgments": [ { "names": [ "an anonymous party" ], "summary": "disclosing these vulnerabilities without coordination" }, { "organization": "Philips", "summary": "reporting the disclosed vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could result in patient 's confidential data being exposed or extracted from Tasy 's database, give unauthorized access, or create a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Healthcare and Public Health", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Argentina, Brazil, Colombia, Dominican Republic, Mexico", "title": "Countries/areas deployed" }, { "category": "other", "text": "Netherlands", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSMA-21-308-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsma-21-308-01.json" }, { "category": "self", "summary": "ICS Advisory ICSMA-21-308-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-21-308-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Philips Tasy EMR", "tracking": { "current_release_date": "2021-11-04T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSMA-21-308-01", "initial_release_date": "2021-11-04T00:00:00.000000Z", "revision_history": [ { "date": "2021-11-04T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSMA-21-308-01 Philips Tasy EMR" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "<= 3.06.1803", "product": { "name": "Tasy EMR HTML5: 3.06.1803 and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Tasy EMR HTML5" } ], "category": "vendor", "name": "Philips" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-39375", "cwe": { "id": "CWE-89", "name": "Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')" }, "notes": [ { "category": "summary", "text": "The affected product allows SQL injection via the WAdvancedFilter/getDimensionItemsByCode FilterValue parameter.CVE-2021-39375 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-39375" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Philips recommends users update Tasy EMR HTML5 to Version 3.06.1804 or later with the latest available service pack where both CVEs are remediated.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Users with questions regarding their specific Philips TASY EMR system are advised by Philips to contact their Customer Success Manager (CSM), local Philips service support team, or regional service support. Users can also contact Philips on itscompany website.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.philips.com.br/healthcare/resources/landing/solucao-tasy#_form" }, { "category": "vendor_fix", "details": "The Philips advisory for these vulnerabilities is available on Philips product security website.", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.philips.com/productsecurity" }, { "category": "vendor_fix", "details": "Please see the Philips product security website for the latest security information for Philips products.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.philips.com/productsecurity" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-39376", "cwe": { "id": "CWE-89", "name": "Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')" }, "notes": [ { "category": "summary", "text": "The affected product allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter.CVE-2021-39376 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-39376" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Philips recommends users update Tasy EMR HTML5 to Version 3.06.1804 or later with the latest available service pack where both CVEs are remediated.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Users with questions regarding their specific Philips TASY EMR system are advised by Philips to contact their Customer Success Manager (CSM), local Philips service support team, or regional service support. Users can also contact Philips on itscompany website.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.philips.com.br/healthcare/resources/landing/solucao-tasy#_form" }, { "category": "vendor_fix", "details": "The Philips advisory for these vulnerabilities is available on Philips product security website.", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.philips.com/productsecurity" }, { "category": "vendor_fix", "details": "Please see the Philips product security website for the latest security information for Philips products.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.philips.com/productsecurity" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }