{ "document": { "acknowledgments": [ { "names": [ "Antonio Cuomo" ], "summary": "reporting these vulnerabilities to Distributed Data Systems and CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow a user with administrative privileges in WebHMI to execute arbitrary OS commands or impact other logged in users.", "title": "Risk evaluation" }, { "category": "other", "text": "Commercial Facilities, Critical Manufacturing, Food and Agriculture, Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Europe and North America", "title": "Countries/areas deployed" }, { "category": "other", "text": "Ukraine", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-22-181-04 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-181-04.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-181-04 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-181-04" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Distributed Data Systems WebHMI", "tracking": { "current_release_date": "2022-06-30T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-181-04", "initial_release_date": "2022-06-30T00:00:00.000000Z", "revision_history": [ { "date": "2022-06-30T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "4.1.1.7662 (and possibly prior versions)", "product": { "name": "WebHMI: 4.1.1.7662 (and possibly prior versions)", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "WebHMI" } ], "category": "vendor", "name": "Distributed Data Systems" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-2254", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" }, "notes": [ { "category": "summary", "text": "A user with administrative privileges in WebHMI can store a script that could impact other logged in users.CVE-2022-2254 has been assigned to this vulnerability. A CVSS v3 base score of 6.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-2254" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Contact Distributed Data Systems for additional details regarding these vulnerabilities and their mitigations.", "product_ids": [ "CSAFPID-0001" ], "url": "http://webhmi.com.ua/en/contact-us-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.2, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2022-2253", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" }, "notes": [ { "category": "summary", "text": "A user with administrative privileges in WebHMI may send OS commands to execute on the host server.CVE-2022-2253 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-2253" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Contact Distributed Data Systems for additional details regarding these vulnerabilities and their mitigations.", "product_ids": [ "CSAFPID-0001" ], "url": "http://webhmi.com.ua/en/contact-us-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.2, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }