{ "document": { "acknowledgments": [ { "names": [ "Martin Strohmeier" ], "organization": "Armasuisse", "summary": "reported these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).", "title": "Legal Notice and Terms of Use" }, { "category": "summary", "text": "ATN-B1 CPDLC relies on legacy clear text unauthenticated radio frequency links. Research demonstrates that these characteristics allow unauthorized message injection, denial-of-service conditions, and forced session resets. These vulnerabilities do not constitute an unsafe aircraft condition but can degrade operational safety margins by increasing workload, delaying safety-critical instructions, and reducing situational awareness.", "title": "Advisory Summary" }, { "category": "other", "text": "Transportation Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Global", "title": "Company headquarters location" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-26-219-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-219-01.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-26-219-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-219-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/secure-our-world/teach-employees-avoid-phishing" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/news/avoiding-social-engineering-and-phishing-attacks" } ], "title": "CPDLC over ATN-B1 Vulnerabilities", "tracking": { "current_release_date": "2026-08-07T05:00:00.000000Z", "generator": { "date": "2026-08-05T22:59:15.799935Z", "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-26-219-01", "initial_release_date": "2026-08-07T05:00:00.000000Z", "revision_history": [ { "date": "2026-08-07T05:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Initial Publication" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Advisory Circular 90-117 Data Link Communications ATN-B1 CPDLC: vers:all/*", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "ATN-B1 CPDLC" } ], "category": "specification", "name": "Advisory Circular 90-117 Data Link Communications" } ] }, "vulnerabilities": [ { "cve": "CVE-2025-71409", "cwe": { "id": "CWE-306", "name": "Missing Authentication for Critical Function" }, "notes": [ { "category": "summary", "text": "Lack of authentication for Very High Frequency Data Link messages allows rogue ground stations to inject CPDLC messages leading to unexpected or misleading clearances and potential pilot confusion. This type of attack can be carried out remotely over radio frequency.", "title": "Vulnerability Summary" }, { "category": "details", "text": "SSVCv2/E:N/A:N/2026-08-05T05:00:00.000000Z", "title": "SSVC" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "cwe.mitre.org", "url": "https://cwe.mitre.org/data/definitions/306.html" }, { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2025-71409" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:H/A:L" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:N/VI:H/VA:L/SC:N/SI:H/SA:L" } ], "remediations": [ { "category": "none_available", "details": "Currently, there is no mitigation available for CVE-2025-71409, CVE-2025-71410, CVE-2025-71411, CVE-2025-71412, CVE-2025-71413.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "These vulnerabilities in the CPDLC protocol stack are exploitable in a lab environment. However, they require very specific conditions to be met and are unlikely to be exploited outside of a lab setting.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:H/A:L", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2025-71410", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "Unnumbered Disconnect (U DISC) and malformed Aviation Very High Frequency Link Control frames can terminate sessions and lead to a loss of CPDLC functions requiring a reversion to voice communication and increased controller workload. This type of attack can be carried out remotely over radio frequency.", "title": "Vulnerability Summary" }, { "category": "details", "text": "SSVCv2/E:N/A:N/2026-08-05T05:00:00.000000Z", "title": "SSVC" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "cwe.mitre.org", "url": "https://cwe.mitre.org/data/definitions/770.html" }, { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2025-71410" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N" } ], "remediations": [ { "category": "none_available", "details": "Currently, there is no mitigation available for CVE-2025-71409, CVE-2025-71410, CVE-2025-71411, CVE-2025-71412, CVE-2025-71413.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "These vulnerabilities in the CPDLC protocol stack are exploitable in a lab environment. However, they require very specific conditions to be met and are unlikely to be exploited outside of a lab setting.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2025-71411", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "Broadcast control frames can disconnect multiple aircraft simultaneously leading to delayed clearances and air traffic controller overload. This type of attack can be carried out remotely over radio frequency.", "title": "Vulnerability Summary" }, { "category": "details", "text": "SSVCv2/E:N/A:N/2026-08-05T05:00:00.000000Z", "title": "SSVC" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "cwe.mitre.org", "url": "https://cwe.mitre.org/data/definitions/770.html" }, { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2025-71411" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N" } ], "remediations": [ { "category": "none_available", "details": "Currently, there is no mitigation available for CVE-2025-71409, CVE-2025-71410, CVE-2025-71411, CVE-2025-71412, CVE-2025-71413.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "These vulnerabilities in the CPDLC protocol stack are exploitable in a lab environment. However, they require very specific conditions to be met and are unlikely to be exploited outside of a lab setting.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2025-71412", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Injection of false emergency or status messages over CPDLC may lead to misallocation of resources, operational confusion, and improper response actions by flight crews, traffic controllers, and ground operations. This type of attack can be carried out remotely over radio frequency.", "title": "Vulnerability Summary" }, { "category": "details", "text": "SSVCv2/E:N/A:N/2026-08-05T05:00:00.000000Z", "title": "SSVC" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "cwe.mitre.org", "url": "https://cwe.mitre.org/data/definitions/754.html" }, { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2025-71412" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:H/A:L" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:N/VI:H/VA:L/SC:N/SI:H/SA:L" } ], "remediations": [ { "category": "none_available", "details": "Currently, there is no mitigation available for CVE-2025-71409, CVE-2025-71410, CVE-2025-71411, CVE-2025-71412, CVE-2025-71413.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "These vulnerabilities in the CPDLC protocol stack are exploitable in a lab environment. However, they require very specific conditions to be met and are unlikely to be exploited outside of a lab setting.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:H/A:L", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2025-71413", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Malformed or out-of-sequence frames at the Aviation Very High Frequency Link Control X.25 layers cause repeated resets which may result in increased workload and reduced situational awareness. This type of attack can be carried out remotely over radio frequency.", "title": "Vulnerability Summary" }, { "category": "details", "text": "SSVCv2/E:N/A:N/2026-08-05T05:00:00.000000Z", "title": "SSVC" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "cwe.mitre.org", "url": "https://cwe.mitre.org/data/definitions/754.html" }, { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2025-71413" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N" } ], "remediations": [ { "category": "none_available", "details": "Currently, there is no mitigation available for CVE-2025-71409, CVE-2025-71410, CVE-2025-71411, CVE-2025-71412, CVE-2025-71413.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "These vulnerabilities in the CPDLC protocol stack are exploitable in a lab environment. However, they require very specific conditions to be met and are unlikely to be exploited outside of a lab setting.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] } ] }