{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reported these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Mendix Studio Pro contains multiple vulnerabilities in the MCP Server, that could allow an attacker with network access to interact with the server remotely or trick a user's browser into sending unauthorized requests, potentially leading to unauthorized data access, tool execution, or system compromise.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).", "title": "Legal Notice and Terms of Use" }, { "category": "other", "text": "This ICSA is a verbatim republication of Siemens ProductCERT SSA-710379 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "Critical Manufacturing, Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-710379: Multiple Vulnerabilities in Mendix Studio Pro's MCP Server - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-710379.json" }, { "category": "self", "summary": "SSA-710379: Multiple Vulnerabilities in Mendix Studio Pro's MCP Server - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-710379.html" }, { "category": "self", "summary": "ICS Advisory ICSA-26-321-05 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-321-05.json" }, { "category": "self", "summary": "ICS Advisory ICSA-26-321-05 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-321-05" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b" } ], "title": "Siemens Mendix Studio Pro", "tracking": { "current_release_date": "2026-11-17T07:00:00.000000Z", "generator": { "date": "2026-11-16T15:49:33.591701Z", "engine": { "name": "CISA CSAF Generator", "version": "1.5.0" } }, "id": "ICSA-26-321-05", "initial_release_date": "2026-11-10T00:00:00.000000Z", "revision_history": [ { "date": "2026-11-10T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Publication Date" }, { "date": "2026-11-16T00:00:00.000000Z", "legacy_version": "Additional Release 1", "number": "2", "summary": "Mapped the advisory to Mendix products to be present on the Mendix Atom Feed" }, { "date": "2026-11-17T07:00:00.000000Z", "legacy_version": "CISA Republication", "number": "3", "summary": "Initial CISA Republication of Siemens ProductCERT SSA-710379 advisory" } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:intdot/>=11.15.0|<11.16.0", "product": { "name": "Mendix Studio Pro 11 >= V11.15.0 < V11.16.0", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Mendix Studio Pro 11" }, { "branches": [ { "category": "product_version_range", "name": "vers:intdot/>=11.12.6|<11.12.7", "product": { "name": "Mendix Studio Pro 11.12 >= V11.12.6 < V11.12.7", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Mendix Studio Pro 11.12" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2026-112136", "cwe": { "id": "CWE-1327", "name": "Binding to an Unrestricted IP Address" }, "notes": [ { "category": "description", "text": "The affected products MCP Server does not properly restrict its HTTP listener to the loopback interface, leaving it potentially exposed to remote systems. This could allow an attacker with network access to interact with the MCP Server remotely.", "title": "CVE Description" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2026-112136" }, { "category": "external", "summary": "cwe.mitre.org", "url": "https://cwe.mitre.org/data/definitions/1327.html" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Maintain strict inbound firewall policies (such as Windows Defender Firewall) blocking external traffic on port 7782. This is already the case by default on standard Windows installations. If remote access is required, restrict traffic via a secure, authenticated channel (e.g., a VPN or SSH tunnel) rather than opening direct inbound firewall rules.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V11.12.7 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://docs.mendix.com/releasenotes/studio-pro/11.12/" }, { "category": "vendor_fix", "details": "Update to V11.16.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://docs.mendix.com/releasenotes/studio-pro/11/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2026-112136" }, { "cve": "CVE-2026-112137", "cwe": { "id": "CWE-352", "name": "Cross-Site Request Forgery (CSRF)" }, "notes": [ { "category": "description", "text": "The affected products MCP Server does not properly validate Content-Type and Origin headers on incoming HTTP requests, leaving it vulnerable to Cross-Site Request Forgery (CSRF). This could allow a malicious web page to trick a user's browser into sending unauthorized requests and executing unintended actions on the local MCP Server.", "title": "CVE Description" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2026-112137" }, { "category": "external", "summary": "cwe.mitre.org", "url": "https://cwe.mitre.org/data/definitions/352.html" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:L" } ], "remediations": [ { "category": "mitigation", "details": "Utilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V11.12.7 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://docs.mendix.com/releasenotes/studio-pro/11.12/" }, { "category": "vendor_fix", "details": "Update to V11.16.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://docs.mendix.com/releasenotes/studio-pro/11/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:L", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2026-112137" } ] }