-- ********************************************************************* -- CISCO-UNIFIED-COMPUTING-IDENT-MIB.my -- -- MIB representation of the Cisco Unified Computing System -- IDENT management information model package -- -- Created July 2018 by Charles Bullis -- -- Copyright (c) 2005-2018 Cisco Systems, Inc. All rights reserved. -- -- ********************************************************************* CISCO-UNIFIED-COMPUTING-IDENT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Gauge32, TimeTicks, Counter64, Unsigned32 FROM SNMPv2-SMI TEXTUAL-CONVENTION, RowPointer, DateAndTime, DisplayString, MacAddress, TimeInterval, TimeStamp, TruthValue FROM SNMPv2-TC SnmpAdminString FROM SNMP-FRAMEWORK-MIB InetAddressIPv4, InetAddressIPv6 FROM INET-ADDRESS-MIB ciscoMgmt FROM CISCO-SMI CiscoNetworkAddress, Unsigned64, CiscoInetAddressMask, CiscoAlarmSeverity, TimeIntervalSec FROM CISCO-TC ciscoUnifiedComputingMIBObjects, CucsManagedObjectId, CucsManagedObjectDn FROM CISCO-UNIFIED-COMPUTING-MIB CucsConditionRemoteInvRslt, CucsFsmCompletion, CucsFsmFlags, CucsFsmFsmStageStatus, CucsIdentConsType, CucsIdentIdDefinedInIdm, CucsIdentIdentReqIntent, CucsIdentIdentRequestFsmCurrentFsm, CucsIdentIdentRequestFsmStageName, CucsIdentIdentRequestFsmTaskItem, CucsIdentIdentType, CucsIdentMetaSystemFsmCurrentFsm, CucsIdentMetaSystemFsmStageName, CucsIdentMetaSystemFsmTaskItem, CucsIdentRetStatus FROM CISCO-UNIFIED-COMPUTING-TC-MIB; cucsIdentObjects MODULE-IDENTITY LAST-UPDATED "201807260000Z" ORGANIZATION "Cisco Systems Inc." CONTACT-INFO "Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553 -NETS E-mail: cs-san@cisco.com, cs-lan-switch-snmp@cisco.com" DESCRIPTION "MIB representation of the Cisco Unified Computing System IDENT management information model package" ::= { ciscoUnifiedComputingMIBObjects 64 } cucsIdentIdentCtxTable OBJECT-TYPE SYNTAX SEQUENCE OF CucsIdentIdentCtxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx managed object table" ::= { cucsIdentObjects 1 } cucsIdentIdentCtxEntry OBJECT-TYPE SYNTAX CucsIdentIdentCtxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the cucsIdentIdentCtxTable table." INDEX { cucsIdentIdentCtxInstanceId } ::= { cucsIdentIdentCtxTable 1 } CucsIdentIdentCtxEntry ::= SEQUENCE { cucsIdentIdentCtxInstanceId CucsManagedObjectId, cucsIdentIdentCtxDn CucsManagedObjectDn, cucsIdentIdentCtxRn SnmpAdminString, cucsIdentIdentCtxAssigned SnmpAdminString, cucsIdentIdentCtxConsDn SnmpAdminString, cucsIdentIdentCtxConsType CucsIdentConsType, cucsIdentIdentCtxDefinedInIdm CucsIdentIdDefinedInIdm, cucsIdentIdentCtxIdentPoolName SnmpAdminString, cucsIdentIdentCtxIdentType CucsIdentIdentType, cucsIdentIdentCtxIntent CucsIdentIdentReqIntent, cucsIdentIdentCtxPoolDn SnmpAdminString, cucsIdentIdentCtxPoolOrgDn SnmpAdminString, cucsIdentIdentCtxPooledId Gauge32, cucsIdentIdentCtxRetStatus CucsIdentRetStatus, cucsIdentIdentCtxSeqNum Gauge32, cucsIdentIdentCtxSupplId1 SnmpAdminString, cucsIdentIdentCtxSupplId2 SnmpAdminString, cucsIdentIdentCtxSupplId3 SnmpAdminString, cucsIdentIdentCtxSupplId4 SnmpAdminString, cucsIdentIdentCtxGlobalAssignedCnt SnmpAdminString, cucsIdentIdentCtxGlobalDefinedCnt SnmpAdminString, cucsIdentIdentCtxIsAssignedLocally TruthValue } cucsIdentIdentCtxInstanceId OBJECT-TYPE SYNTAX CucsManagedObjectId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Instance identifier of the managed object." ::= { cucsIdentIdentCtxEntry 1 } cucsIdentIdentCtxDn OBJECT-TYPE SYNTAX CucsManagedObjectDn MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:dn managed object property" ::= { cucsIdentIdentCtxEntry 2 } cucsIdentIdentCtxRn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:rn managed object property" ::= { cucsIdentIdentCtxEntry 3 } cucsIdentIdentCtxAssigned OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:assigned managed object property" ::= { cucsIdentIdentCtxEntry 4 } cucsIdentIdentCtxConsDn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:consDn managed object property" ::= { cucsIdentIdentCtxEntry 5 } cucsIdentIdentCtxConsType OBJECT-TYPE SYNTAX CucsIdentConsType MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:consType managed object property" ::= { cucsIdentIdentCtxEntry 6 } cucsIdentIdentCtxDefinedInIdm OBJECT-TYPE SYNTAX CucsIdentIdDefinedInIdm MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:definedInIdm managed object property" ::= { cucsIdentIdentCtxEntry 7 } cucsIdentIdentCtxIdentPoolName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:identPoolName managed object property" ::= { cucsIdentIdentCtxEntry 8 } cucsIdentIdentCtxIdentType OBJECT-TYPE SYNTAX CucsIdentIdentType MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:identType managed object property" ::= { cucsIdentIdentCtxEntry 9 } cucsIdentIdentCtxIntent OBJECT-TYPE SYNTAX CucsIdentIdentReqIntent MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:intent managed object property" ::= { cucsIdentIdentCtxEntry 10 } cucsIdentIdentCtxPoolDn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:poolDn managed object property" ::= { cucsIdentIdentCtxEntry 11 } cucsIdentIdentCtxPoolOrgDn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:poolOrgDn managed object property" ::= { cucsIdentIdentCtxEntry 12 } cucsIdentIdentCtxPooledId OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:pooledId managed object property" ::= { cucsIdentIdentCtxEntry 13 } cucsIdentIdentCtxRetStatus OBJECT-TYPE SYNTAX CucsIdentRetStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:retStatus managed object property" ::= { cucsIdentIdentCtxEntry 14 } cucsIdentIdentCtxSeqNum OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:seqNum managed object property" ::= { cucsIdentIdentCtxEntry 15 } cucsIdentIdentCtxSupplId1 OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:supplId1 managed object property" ::= { cucsIdentIdentCtxEntry 16 } cucsIdentIdentCtxSupplId2 OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:supplId2 managed object property" ::= { cucsIdentIdentCtxEntry 17 } cucsIdentIdentCtxSupplId3 OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:supplId3 managed object property" ::= { cucsIdentIdentCtxEntry 18 } cucsIdentIdentCtxSupplId4 OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:supplId4 managed object property" ::= { cucsIdentIdentCtxEntry 19 } cucsIdentIdentCtxGlobalAssignedCnt OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:globalAssignedCnt managed object property" ::= { cucsIdentIdentCtxEntry 20 } cucsIdentIdentCtxGlobalDefinedCnt OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:globalDefinedCnt managed object property" ::= { cucsIdentIdentCtxEntry 21 } cucsIdentIdentCtxIsAssignedLocally OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentCtx:isAssignedLocally managed object property" ::= { cucsIdentIdentCtxEntry 22 } cucsIdentIdentRequestTable OBJECT-TYPE SYNTAX SEQUENCE OF CucsIdentIdentRequestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest managed object table" ::= { cucsIdentObjects 2 } cucsIdentIdentRequestEntry OBJECT-TYPE SYNTAX CucsIdentIdentRequestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the cucsIdentIdentRequestTable table." INDEX { cucsIdentIdentRequestInstanceId } ::= { cucsIdentIdentRequestTable 1 } CucsIdentIdentRequestEntry ::= SEQUENCE { cucsIdentIdentRequestInstanceId CucsManagedObjectId, cucsIdentIdentRequestDn CucsManagedObjectDn, cucsIdentIdentRequestRn SnmpAdminString, cucsIdentIdentRequestEpDn SnmpAdminString, cucsIdentIdentRequestFsmDescr SnmpAdminString, cucsIdentIdentRequestFsmPrev SnmpAdminString, cucsIdentIdentRequestFsmProgr Gauge32, cucsIdentIdentRequestFsmRmtInvErrCode Gauge32, cucsIdentIdentRequestFsmRmtInvErrDescr SnmpAdminString, cucsIdentIdentRequestFsmRmtInvRslt CucsConditionRemoteInvRslt, cucsIdentIdentRequestFsmStageDescr SnmpAdminString, cucsIdentIdentRequestFsmStamp DateAndTime, cucsIdentIdentRequestFsmStatus SnmpAdminString, cucsIdentIdentRequestFsmTry Gauge32, cucsIdentIdentRequestId Gauge32, cucsIdentIdentRequestRequestSize Gauge32, cucsIdentIdentRequestSeqNum Gauge32 } cucsIdentIdentRequestInstanceId OBJECT-TYPE SYNTAX CucsManagedObjectId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Instance identifier of the managed object." ::= { cucsIdentIdentRequestEntry 1 } cucsIdentIdentRequestDn OBJECT-TYPE SYNTAX CucsManagedObjectDn MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:dn managed object property" ::= { cucsIdentIdentRequestEntry 2 } cucsIdentIdentRequestRn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:rn managed object property" ::= { cucsIdentIdentRequestEntry 3 } cucsIdentIdentRequestEpDn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:epDn managed object property" ::= { cucsIdentIdentRequestEntry 4 } cucsIdentIdentRequestFsmDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:fsmDescr managed object property" ::= { cucsIdentIdentRequestEntry 5 } cucsIdentIdentRequestFsmPrev OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:fsmPrev managed object property" ::= { cucsIdentIdentRequestEntry 6 } cucsIdentIdentRequestFsmProgr OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:fsmProgr managed object property" ::= { cucsIdentIdentRequestEntry 7 } cucsIdentIdentRequestFsmRmtInvErrCode OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:fsmRmtInvErrCode managed object property" ::= { cucsIdentIdentRequestEntry 8 } cucsIdentIdentRequestFsmRmtInvErrDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:fsmRmtInvErrDescr managed object property" ::= { cucsIdentIdentRequestEntry 9 } cucsIdentIdentRequestFsmRmtInvRslt OBJECT-TYPE SYNTAX CucsConditionRemoteInvRslt MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:fsmRmtInvRslt managed object property" ::= { cucsIdentIdentRequestEntry 10 } cucsIdentIdentRequestFsmStageDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:fsmStageDescr managed object property" ::= { cucsIdentIdentRequestEntry 11 } cucsIdentIdentRequestFsmStamp OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:fsmStamp managed object property" ::= { cucsIdentIdentRequestEntry 12 } cucsIdentIdentRequestFsmStatus OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:fsmStatus managed object property" ::= { cucsIdentIdentRequestEntry 13 } cucsIdentIdentRequestFsmTry OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:fsmTry managed object property" ::= { cucsIdentIdentRequestEntry 14 } cucsIdentIdentRequestId OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:id managed object property" ::= { cucsIdentIdentRequestEntry 15 } cucsIdentIdentRequestRequestSize OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:requestSize managed object property" ::= { cucsIdentIdentRequestEntry 16 } cucsIdentIdentRequestSeqNum OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequest:seqNum managed object property" ::= { cucsIdentIdentRequestEntry 17 } cucsIdentIdentRequestFsmTable OBJECT-TYPE SYNTAX SEQUENCE OF CucsIdentIdentRequestFsmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsm managed object table" ::= { cucsIdentObjects 3 } cucsIdentIdentRequestFsmEntry OBJECT-TYPE SYNTAX CucsIdentIdentRequestFsmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the cucsIdentIdentRequestFsmTable table." INDEX { cucsIdentIdentRequestFsmInstanceId } ::= { cucsIdentIdentRequestFsmTable 1 } CucsIdentIdentRequestFsmEntry ::= SEQUENCE { cucsIdentIdentRequestFsmInstanceId CucsManagedObjectId, cucsIdentIdentRequestFsmDn CucsManagedObjectDn, cucsIdentIdentRequestFsmRn SnmpAdminString, cucsIdentIdentRequestFsmCompletionTime DateAndTime, cucsIdentIdentRequestFsmCurrentFsm CucsIdentIdentRequestFsmCurrentFsm, cucsIdentIdentRequestFsmDescrData SnmpAdminString, cucsIdentIdentRequestFsmFsmStatus CucsFsmFsmStageStatus, cucsIdentIdentRequestFsmProgress Gauge32, cucsIdentIdentRequestFsmRmtErrCode Gauge32, cucsIdentIdentRequestFsmRmtErrDescr SnmpAdminString, cucsIdentIdentRequestFsmRmtRslt CucsConditionRemoteInvRslt } cucsIdentIdentRequestFsmInstanceId OBJECT-TYPE SYNTAX CucsManagedObjectId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Instance identifier of the managed object." ::= { cucsIdentIdentRequestFsmEntry 1 } cucsIdentIdentRequestFsmDn OBJECT-TYPE SYNTAX CucsManagedObjectDn MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsm:dn managed object property" ::= { cucsIdentIdentRequestFsmEntry 2 } cucsIdentIdentRequestFsmRn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsm:rn managed object property" ::= { cucsIdentIdentRequestFsmEntry 3 } cucsIdentIdentRequestFsmCompletionTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsm:completionTime managed object property" ::= { cucsIdentIdentRequestFsmEntry 4 } cucsIdentIdentRequestFsmCurrentFsm OBJECT-TYPE SYNTAX CucsIdentIdentRequestFsmCurrentFsm MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsm:currentFsm managed object property" ::= { cucsIdentIdentRequestFsmEntry 5 } cucsIdentIdentRequestFsmDescrData OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsm:descr managed object property" ::= { cucsIdentIdentRequestFsmEntry 6 } cucsIdentIdentRequestFsmFsmStatus OBJECT-TYPE SYNTAX CucsFsmFsmStageStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsm:fsmStatus managed object property" ::= { cucsIdentIdentRequestFsmEntry 7 } cucsIdentIdentRequestFsmProgress OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsm:progress managed object property" ::= { cucsIdentIdentRequestFsmEntry 8 } cucsIdentIdentRequestFsmRmtErrCode OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsm:rmtErrCode managed object property" ::= { cucsIdentIdentRequestFsmEntry 9 } cucsIdentIdentRequestFsmRmtErrDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsm:rmtErrDescr managed object property" ::= { cucsIdentIdentRequestFsmEntry 10 } cucsIdentIdentRequestFsmRmtRslt OBJECT-TYPE SYNTAX CucsConditionRemoteInvRslt MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsm:rmtRslt managed object property" ::= { cucsIdentIdentRequestFsmEntry 11 } cucsIdentIdentRequestFsmStageTable OBJECT-TYPE SYNTAX SEQUENCE OF CucsIdentIdentRequestFsmStageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmStage managed object table" ::= { cucsIdentObjects 4 } cucsIdentIdentRequestFsmStageEntry OBJECT-TYPE SYNTAX CucsIdentIdentRequestFsmStageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the cucsIdentIdentRequestFsmStageTable table." INDEX { cucsIdentIdentRequestFsmStageInstanceId } ::= { cucsIdentIdentRequestFsmStageTable 1 } CucsIdentIdentRequestFsmStageEntry ::= SEQUENCE { cucsIdentIdentRequestFsmStageInstanceId CucsManagedObjectId, cucsIdentIdentRequestFsmStageDn CucsManagedObjectDn, cucsIdentIdentRequestFsmStageRn SnmpAdminString, cucsIdentIdentRequestFsmStageDescrData SnmpAdminString, cucsIdentIdentRequestFsmStageLastUpdateTime DateAndTime, cucsIdentIdentRequestFsmStageName CucsIdentIdentRequestFsmStageName, cucsIdentIdentRequestFsmStageOrder Gauge32, cucsIdentIdentRequestFsmStageRetry Gauge32, cucsIdentIdentRequestFsmStageStageStatus CucsFsmFsmStageStatus } cucsIdentIdentRequestFsmStageInstanceId OBJECT-TYPE SYNTAX CucsManagedObjectId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Instance identifier of the managed object." ::= { cucsIdentIdentRequestFsmStageEntry 1 } cucsIdentIdentRequestFsmStageDn OBJECT-TYPE SYNTAX CucsManagedObjectDn MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmStage:dn managed object property" ::= { cucsIdentIdentRequestFsmStageEntry 2 } cucsIdentIdentRequestFsmStageRn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmStage:rn managed object property" ::= { cucsIdentIdentRequestFsmStageEntry 3 } cucsIdentIdentRequestFsmStageDescrData OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmStage:descr managed object property" ::= { cucsIdentIdentRequestFsmStageEntry 4 } cucsIdentIdentRequestFsmStageLastUpdateTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmStage:lastUpdateTime managed object property" ::= { cucsIdentIdentRequestFsmStageEntry 5 } cucsIdentIdentRequestFsmStageName OBJECT-TYPE SYNTAX CucsIdentIdentRequestFsmStageName MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmStage:name managed object property" ::= { cucsIdentIdentRequestFsmStageEntry 6 } cucsIdentIdentRequestFsmStageOrder OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmStage:order managed object property" ::= { cucsIdentIdentRequestFsmStageEntry 7 } cucsIdentIdentRequestFsmStageRetry OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmStage:retry managed object property" ::= { cucsIdentIdentRequestFsmStageEntry 8 } cucsIdentIdentRequestFsmStageStageStatus OBJECT-TYPE SYNTAX CucsFsmFsmStageStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmStage:stageStatus managed object property" ::= { cucsIdentIdentRequestFsmStageEntry 9 } cucsIdentIdentRequestFsmTaskTable OBJECT-TYPE SYNTAX SEQUENCE OF CucsIdentIdentRequestFsmTaskEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmTask managed object table" ::= { cucsIdentObjects 5 } cucsIdentIdentRequestFsmTaskEntry OBJECT-TYPE SYNTAX CucsIdentIdentRequestFsmTaskEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the cucsIdentIdentRequestFsmTaskTable table." INDEX { cucsIdentIdentRequestFsmTaskInstanceId } ::= { cucsIdentIdentRequestFsmTaskTable 1 } CucsIdentIdentRequestFsmTaskEntry ::= SEQUENCE { cucsIdentIdentRequestFsmTaskInstanceId CucsManagedObjectId, cucsIdentIdentRequestFsmTaskDn CucsManagedObjectDn, cucsIdentIdentRequestFsmTaskRn SnmpAdminString, cucsIdentIdentRequestFsmTaskCompletion CucsFsmCompletion, cucsIdentIdentRequestFsmTaskFlags CucsIdentIdentRequestFsmTaskFlags, cucsIdentIdentRequestFsmTaskItem CucsIdentIdentRequestFsmTaskItem, cucsIdentIdentRequestFsmTaskSeqId Gauge32 } cucsIdentIdentRequestFsmTaskInstanceId OBJECT-TYPE SYNTAX CucsManagedObjectId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Instance identifier of the managed object." ::= { cucsIdentIdentRequestFsmTaskEntry 1 } cucsIdentIdentRequestFsmTaskDn OBJECT-TYPE SYNTAX CucsManagedObjectDn MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmTask:dn managed object property" ::= { cucsIdentIdentRequestFsmTaskEntry 2 } cucsIdentIdentRequestFsmTaskRn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmTask:rn managed object property" ::= { cucsIdentIdentRequestFsmTaskEntry 3 } cucsIdentIdentRequestFsmTaskCompletion OBJECT-TYPE SYNTAX CucsFsmCompletion MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmTask:completion managed object property" ::= { cucsIdentIdentRequestFsmTaskEntry 4 } cucsIdentIdentRequestFsmTaskFlags OBJECT-TYPE SYNTAX CucsIdentIdentRequestFsmTaskFlags MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmTask:flags managed object property" ::= { cucsIdentIdentRequestFsmTaskEntry 5 } cucsIdentIdentRequestFsmTaskItem OBJECT-TYPE SYNTAX CucsIdentIdentRequestFsmTaskItem MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmTask:item managed object property" ::= { cucsIdentIdentRequestFsmTaskEntry 6 } cucsIdentIdentRequestFsmTaskSeqId OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:IdentRequestFsmTask:seqId managed object property" ::= { cucsIdentIdentRequestFsmTaskEntry 7 } cucsIdentMetaSystemTable OBJECT-TYPE SYNTAX SEQUENCE OF CucsIdentMetaSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem managed object table" ::= { cucsIdentObjects 6 } cucsIdentMetaSystemEntry OBJECT-TYPE SYNTAX CucsIdentMetaSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the cucsIdentMetaSystemTable table." INDEX { cucsIdentMetaSystemInstanceId } ::= { cucsIdentMetaSystemTable 1 } CucsIdentMetaSystemEntry ::= SEQUENCE { cucsIdentMetaSystemInstanceId CucsManagedObjectId, cucsIdentMetaSystemDn CucsManagedObjectDn, cucsIdentMetaSystemRn SnmpAdminString, cucsIdentMetaSystemFsmDescr SnmpAdminString, cucsIdentMetaSystemFsmPrev SnmpAdminString, cucsIdentMetaSystemFsmProgr Gauge32, cucsIdentMetaSystemFsmRmtInvErrCode Gauge32, cucsIdentMetaSystemFsmRmtInvErrDescr SnmpAdminString, cucsIdentMetaSystemFsmRmtInvRslt CucsConditionRemoteInvRslt, cucsIdentMetaSystemFsmStageDescr SnmpAdminString, cucsIdentMetaSystemFsmStamp DateAndTime, cucsIdentMetaSystemFsmStatus SnmpAdminString, cucsIdentMetaSystemFsmTry Gauge32, cucsIdentMetaSystemGeneration Gauge32, cucsIdentMetaSystemNextReqId Gauge32, cucsIdentMetaSystemSysid Gauge32, cucsIdentMetaSystemUcscGeneration Gauge32 } cucsIdentMetaSystemInstanceId OBJECT-TYPE SYNTAX CucsManagedObjectId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Instance identifier of the managed object." ::= { cucsIdentMetaSystemEntry 1 } cucsIdentMetaSystemDn OBJECT-TYPE SYNTAX CucsManagedObjectDn MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:dn managed object property" ::= { cucsIdentMetaSystemEntry 2 } cucsIdentMetaSystemRn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:rn managed object property" ::= { cucsIdentMetaSystemEntry 3 } cucsIdentMetaSystemFsmDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:fsmDescr managed object property" ::= { cucsIdentMetaSystemEntry 4 } cucsIdentMetaSystemFsmPrev OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:fsmPrev managed object property" ::= { cucsIdentMetaSystemEntry 5 } cucsIdentMetaSystemFsmProgr OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:fsmProgr managed object property" ::= { cucsIdentMetaSystemEntry 6 } cucsIdentMetaSystemFsmRmtInvErrCode OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:fsmRmtInvErrCode managed object property" ::= { cucsIdentMetaSystemEntry 7 } cucsIdentMetaSystemFsmRmtInvErrDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:fsmRmtInvErrDescr managed object property" ::= { cucsIdentMetaSystemEntry 8 } cucsIdentMetaSystemFsmRmtInvRslt OBJECT-TYPE SYNTAX CucsConditionRemoteInvRslt MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:fsmRmtInvRslt managed object property" ::= { cucsIdentMetaSystemEntry 9 } cucsIdentMetaSystemFsmStageDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:fsmStageDescr managed object property" ::= { cucsIdentMetaSystemEntry 10 } cucsIdentMetaSystemFsmStamp OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:fsmStamp managed object property" ::= { cucsIdentMetaSystemEntry 11 } cucsIdentMetaSystemFsmStatus OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:fsmStatus managed object property" ::= { cucsIdentMetaSystemEntry 12 } cucsIdentMetaSystemFsmTry OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:fsmTry managed object property" ::= { cucsIdentMetaSystemEntry 13 } cucsIdentMetaSystemGeneration OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:generation managed object property" ::= { cucsIdentMetaSystemEntry 14 } cucsIdentMetaSystemNextReqId OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:nextReqId managed object property" ::= { cucsIdentMetaSystemEntry 15 } cucsIdentMetaSystemSysid OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:sysid managed object property" ::= { cucsIdentMetaSystemEntry 16 } cucsIdentMetaSystemUcscGeneration OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystem:ucscGeneration managed object property" ::= { cucsIdentMetaSystemEntry 17 } cucsIdentMetaSystemFsmTable OBJECT-TYPE SYNTAX SEQUENCE OF CucsIdentMetaSystemFsmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsm managed object table" ::= { cucsIdentObjects 7 } cucsIdentMetaSystemFsmEntry OBJECT-TYPE SYNTAX CucsIdentMetaSystemFsmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the cucsIdentMetaSystemFsmTable table." INDEX { cucsIdentMetaSystemFsmInstanceId } ::= { cucsIdentMetaSystemFsmTable 1 } CucsIdentMetaSystemFsmEntry ::= SEQUENCE { cucsIdentMetaSystemFsmInstanceId CucsManagedObjectId, cucsIdentMetaSystemFsmDn CucsManagedObjectDn, cucsIdentMetaSystemFsmRn SnmpAdminString, cucsIdentMetaSystemFsmCompletionTime DateAndTime, cucsIdentMetaSystemFsmCurrentFsm CucsIdentMetaSystemFsmCurrentFsm, cucsIdentMetaSystemFsmDescrData SnmpAdminString, cucsIdentMetaSystemFsmFsmStatus CucsFsmFsmStageStatus, cucsIdentMetaSystemFsmProgress Gauge32, cucsIdentMetaSystemFsmRmtErrCode Gauge32, cucsIdentMetaSystemFsmRmtErrDescr SnmpAdminString, cucsIdentMetaSystemFsmRmtRslt CucsConditionRemoteInvRslt } cucsIdentMetaSystemFsmInstanceId OBJECT-TYPE SYNTAX CucsManagedObjectId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Instance identifier of the managed object." ::= { cucsIdentMetaSystemFsmEntry 1 } cucsIdentMetaSystemFsmDn OBJECT-TYPE SYNTAX CucsManagedObjectDn MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsm:dn managed object property" ::= { cucsIdentMetaSystemFsmEntry 2 } cucsIdentMetaSystemFsmRn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsm:rn managed object property" ::= { cucsIdentMetaSystemFsmEntry 3 } cucsIdentMetaSystemFsmCompletionTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsm:completionTime managed object property" ::= { cucsIdentMetaSystemFsmEntry 4 } cucsIdentMetaSystemFsmCurrentFsm OBJECT-TYPE SYNTAX CucsIdentMetaSystemFsmCurrentFsm MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsm:currentFsm managed object property" ::= { cucsIdentMetaSystemFsmEntry 5 } cucsIdentMetaSystemFsmDescrData OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsm:descr managed object property" ::= { cucsIdentMetaSystemFsmEntry 6 } cucsIdentMetaSystemFsmFsmStatus OBJECT-TYPE SYNTAX CucsFsmFsmStageStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsm:fsmStatus managed object property" ::= { cucsIdentMetaSystemFsmEntry 7 } cucsIdentMetaSystemFsmProgress OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsm:progress managed object property" ::= { cucsIdentMetaSystemFsmEntry 8 } cucsIdentMetaSystemFsmRmtErrCode OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsm:rmtErrCode managed object property" ::= { cucsIdentMetaSystemFsmEntry 9 } cucsIdentMetaSystemFsmRmtErrDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsm:rmtErrDescr managed object property" ::= { cucsIdentMetaSystemFsmEntry 10 } cucsIdentMetaSystemFsmRmtRslt OBJECT-TYPE SYNTAX CucsConditionRemoteInvRslt MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsm:rmtRslt managed object property" ::= { cucsIdentMetaSystemFsmEntry 11 } cucsIdentMetaSystemFsmStageTable OBJECT-TYPE SYNTAX SEQUENCE OF CucsIdentMetaSystemFsmStageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmStage managed object table" ::= { cucsIdentObjects 8 } cucsIdentMetaSystemFsmStageEntry OBJECT-TYPE SYNTAX CucsIdentMetaSystemFsmStageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the cucsIdentMetaSystemFsmStageTable table." INDEX { cucsIdentMetaSystemFsmStageInstanceId } ::= { cucsIdentMetaSystemFsmStageTable 1 } CucsIdentMetaSystemFsmStageEntry ::= SEQUENCE { cucsIdentMetaSystemFsmStageInstanceId CucsManagedObjectId, cucsIdentMetaSystemFsmStageDn CucsManagedObjectDn, cucsIdentMetaSystemFsmStageRn SnmpAdminString, cucsIdentMetaSystemFsmStageDescrData SnmpAdminString, cucsIdentMetaSystemFsmStageLastUpdateTime DateAndTime, cucsIdentMetaSystemFsmStageName CucsIdentMetaSystemFsmStageName, cucsIdentMetaSystemFsmStageOrder Gauge32, cucsIdentMetaSystemFsmStageRetry Gauge32, cucsIdentMetaSystemFsmStageStageStatus CucsFsmFsmStageStatus } cucsIdentMetaSystemFsmStageInstanceId OBJECT-TYPE SYNTAX CucsManagedObjectId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Instance identifier of the managed object." ::= { cucsIdentMetaSystemFsmStageEntry 1 } cucsIdentMetaSystemFsmStageDn OBJECT-TYPE SYNTAX CucsManagedObjectDn MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmStage:dn managed object property" ::= { cucsIdentMetaSystemFsmStageEntry 2 } cucsIdentMetaSystemFsmStageRn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmStage:rn managed object property" ::= { cucsIdentMetaSystemFsmStageEntry 3 } cucsIdentMetaSystemFsmStageDescrData OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmStage:descr managed object property" ::= { cucsIdentMetaSystemFsmStageEntry 4 } cucsIdentMetaSystemFsmStageLastUpdateTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmStage:lastUpdateTime managed object property" ::= { cucsIdentMetaSystemFsmStageEntry 5 } cucsIdentMetaSystemFsmStageName OBJECT-TYPE SYNTAX CucsIdentMetaSystemFsmStageName MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmStage:name managed object property" ::= { cucsIdentMetaSystemFsmStageEntry 6 } cucsIdentMetaSystemFsmStageOrder OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmStage:order managed object property" ::= { cucsIdentMetaSystemFsmStageEntry 7 } cucsIdentMetaSystemFsmStageRetry OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmStage:retry managed object property" ::= { cucsIdentMetaSystemFsmStageEntry 8 } cucsIdentMetaSystemFsmStageStageStatus OBJECT-TYPE SYNTAX CucsFsmFsmStageStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmStage:stageStatus managed object property" ::= { cucsIdentMetaSystemFsmStageEntry 9 } cucsIdentMetaSystemFsmTaskTable OBJECT-TYPE SYNTAX SEQUENCE OF CucsIdentMetaSystemFsmTaskEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmTask managed object table" ::= { cucsIdentObjects 9 } cucsIdentMetaSystemFsmTaskEntry OBJECT-TYPE SYNTAX CucsIdentMetaSystemFsmTaskEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the cucsIdentMetaSystemFsmTaskTable table." INDEX { cucsIdentMetaSystemFsmTaskInstanceId } ::= { cucsIdentMetaSystemFsmTaskTable 1 } CucsIdentMetaSystemFsmTaskEntry ::= SEQUENCE { cucsIdentMetaSystemFsmTaskInstanceId CucsManagedObjectId, cucsIdentMetaSystemFsmTaskDn CucsManagedObjectDn, cucsIdentMetaSystemFsmTaskRn SnmpAdminString, cucsIdentMetaSystemFsmTaskCompletion CucsFsmCompletion, cucsIdentMetaSystemFsmTaskFlags CucsFsmFlags, cucsIdentMetaSystemFsmTaskItem CucsIdentMetaSystemFsmTaskItem, cucsIdentMetaSystemFsmTaskSeqId Gauge32 } cucsIdentMetaSystemFsmTaskInstanceId OBJECT-TYPE SYNTAX CucsManagedObjectId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Instance identifier of the managed object." ::= { cucsIdentMetaSystemFsmTaskEntry 1 } cucsIdentMetaSystemFsmTaskDn OBJECT-TYPE SYNTAX CucsManagedObjectDn MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmTask:dn managed object property" ::= { cucsIdentMetaSystemFsmTaskEntry 2 } cucsIdentMetaSystemFsmTaskRn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmTask:rn managed object property" ::= { cucsIdentMetaSystemFsmTaskEntry 3 } cucsIdentMetaSystemFsmTaskCompletion OBJECT-TYPE SYNTAX CucsFsmCompletion MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmTask:completion managed object property" ::= { cucsIdentMetaSystemFsmTaskEntry 4 } cucsIdentMetaSystemFsmTaskFlags OBJECT-TYPE SYNTAX CucsFsmFlags MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmTask:flags managed object property" ::= { cucsIdentMetaSystemFsmTaskEntry 5 } cucsIdentMetaSystemFsmTaskItem OBJECT-TYPE SYNTAX CucsIdentMetaSystemFsmTaskItem MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmTask:item managed object property" ::= { cucsIdentMetaSystemFsmTaskEntry 6 } cucsIdentMetaSystemFsmTaskSeqId OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaSystemFsmTask:seqId managed object property" ::= { cucsIdentMetaSystemFsmTaskEntry 7 } cucsIdentMetaVerseTable OBJECT-TYPE SYNTAX SEQUENCE OF CucsIdentMetaVerseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cisco UCS ident:MetaVerse managed object table" ::= { cucsIdentObjects 10 } cucsIdentMetaVerseEntry OBJECT-TYPE SYNTAX CucsIdentMetaVerseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the cucsIdentMetaVerseTable table." INDEX { cucsIdentMetaVerseInstanceId } ::= { cucsIdentMetaVerseTable 1 } CucsIdentMetaVerseEntry ::= SEQUENCE { cucsIdentMetaVerseInstanceId CucsManagedObjectId, cucsIdentMetaVerseDn CucsManagedObjectDn, cucsIdentMetaVerseRn SnmpAdminString } cucsIdentMetaVerseInstanceId OBJECT-TYPE SYNTAX CucsManagedObjectId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Instance identifier of the managed object." ::= { cucsIdentMetaVerseEntry 1 } cucsIdentMetaVerseDn OBJECT-TYPE SYNTAX CucsManagedObjectDn MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaVerse:dn managed object property" ::= { cucsIdentMetaVerseEntry 2 } cucsIdentMetaVerseRn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:MetaVerse:rn managed object property" ::= { cucsIdentMetaVerseEntry 3 } cucsIdentRequestEpTable OBJECT-TYPE SYNTAX SEQUENCE OF CucsIdentRequestEpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cisco UCS ident:RequestEp managed object table" ::= { cucsIdentObjects 11 } cucsIdentRequestEpEntry OBJECT-TYPE SYNTAX CucsIdentRequestEpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the cucsIdentRequestEpTable table." INDEX { cucsIdentRequestEpInstanceId } ::= { cucsIdentRequestEpTable 1 } CucsIdentRequestEpEntry ::= SEQUENCE { cucsIdentRequestEpInstanceId CucsManagedObjectId, cucsIdentRequestEpDn CucsManagedObjectDn, cucsIdentRequestEpRn SnmpAdminString, cucsIdentRequestEpReqDn SnmpAdminString, cucsIdentRequestEpReqId Gauge32 } cucsIdentRequestEpInstanceId OBJECT-TYPE SYNTAX CucsManagedObjectId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Instance identifier of the managed object." ::= { cucsIdentRequestEpEntry 1 } cucsIdentRequestEpDn OBJECT-TYPE SYNTAX CucsManagedObjectDn MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:RequestEp:dn managed object property" ::= { cucsIdentRequestEpEntry 2 } cucsIdentRequestEpRn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:RequestEp:rn managed object property" ::= { cucsIdentRequestEpEntry 3 } cucsIdentRequestEpReqDn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:RequestEp:reqDn managed object property" ::= { cucsIdentRequestEpEntry 4 } cucsIdentRequestEpReqId OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:RequestEp:reqId managed object property" ::= { cucsIdentRequestEpEntry 5 } cucsIdentSysInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF CucsIdentSysInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cisco UCS ident:SysInfo managed object table" ::= { cucsIdentObjects 12 } cucsIdentSysInfoEntry OBJECT-TYPE SYNTAX CucsIdentSysInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the cucsIdentSysInfoTable table." INDEX { cucsIdentSysInfoInstanceId } ::= { cucsIdentSysInfoTable 1 } CucsIdentSysInfoEntry ::= SEQUENCE { cucsIdentSysInfoInstanceId CucsManagedObjectId, cucsIdentSysInfoDn CucsManagedObjectDn, cucsIdentSysInfoRn SnmpAdminString, cucsIdentSysInfoGeneration Gauge32, cucsIdentSysInfoIsSync TruthValue, cucsIdentSysInfoIsSyncAllowed TruthValue, cucsIdentSysInfoIsFirstSync TruthValue, cucsIdentSysInfoUcscGeneration Gauge32 } cucsIdentSysInfoInstanceId OBJECT-TYPE SYNTAX CucsManagedObjectId MAX-ACCESS not-accessible STATUS current DESCRIPTION "Instance identifier of the managed object." ::= { cucsIdentSysInfoEntry 1 } cucsIdentSysInfoDn OBJECT-TYPE SYNTAX CucsManagedObjectDn MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:SysInfo:dn managed object property" ::= { cucsIdentSysInfoEntry 2 } cucsIdentSysInfoRn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:SysInfo:rn managed object property" ::= { cucsIdentSysInfoEntry 3 } cucsIdentSysInfoGeneration OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:SysInfo:generation managed object property" ::= { cucsIdentSysInfoEntry 4 } cucsIdentSysInfoIsSync OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:SysInfo:isSync managed object property" ::= { cucsIdentSysInfoEntry 5 } cucsIdentSysInfoIsSyncAllowed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:SysInfo:isSyncAllowed managed object property" ::= { cucsIdentSysInfoEntry 6 } cucsIdentSysInfoIsFirstSync OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:SysInfo:isFirstSync managed object property" ::= { cucsIdentSysInfoEntry 7 } cucsIdentSysInfoUcscGeneration OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cisco UCS ident:SysInfo:ucscGeneration managed object property" ::= { cucsIdentSysInfoEntry 8 } END