-- MIB file created 29-Jun-2009 13:28:16, by -- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com CISCO-BOOT-HWDIAGS-MIB DEFINITIONS ::= BEGIN -- From file: "CISCO-BOOT-HWDIAGS-MIB.my" -- Compile options "4 7 F H N O W 03 06 0B 0G 0N 0T" IMPORTS DisplayString, TruthValue FROM SNMPv2-TC-v1 ciscoMgmt FROM CISCO-SMI Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; ciscoBootHwDiagsMIB OBJECT IDENTIFIER ::= { ciscoMgmt 696 } -- MODULE-IDENTITY -- LastUpdated -- 200905120000Z -- OrgName -- Cisco Systems, Inc. -- ContactInfo -- Cisco Systems -- Customer Service -- -- Postal: 170 W Tasman Drive -- San Jose, CA 95134 -- USA -- -- Tel: +1 800 553-NETS -- -- E-mail: tac@cisco.com -- Descr -- This MIB is used to configure those devices that support -- boot-time hardware diagnostics. It provides the reports -- about the respective diagnostic tests executed by the -- devices as well. -- -- Boot-time diagnostics are run after the ROMMON has -- transferred control to the start code of IOS and before -- any IOS subsystem has started. -- -- Such diagnostics may or may not include those that are -- destructive to the operation of IOS or communications -- links that are serviced by IOS and, as such, must be run -- before IOS has completed booting and before any subsystem -- has started. -- -- During boot-up from either power-on or a reload, and -- before IOS starts, a loop of all such diagnostics is executed -- according to the following flow: -- -- bank = current_bank -- for index = 1 to number of diagnostics { -- if diag[index] is configured AND armed for bank { -- call diagnostic_function[index]; -- store results in memory = structure.bank.index; -- } -- -- After all the IOS subsystems have started, one can -- use either the CLI or this MIB to query the status of the -- diagnostic tests for each bank. -- -- The diagnostic tests are tabulated on the CLI as -- follows. -- -- Information for Hardware Diagnostics Bank 0 -- (Current bank = 0) -- -- Last Boot Next Boot -- - -- Diagnostic Ran? Pass/Failed? Configured? Armed? -- -- EDAC test YES PASSED YES NO -- EEPROM test YES PASSED YES NO -- FPGA(s) test YES FAILED YES NO -- -- FPGA Diags: FPGA1:F, FPGA2-REG:P, FPGA2-SRAM:P, FPGA3:F -- -- -- In the table above, there are 3 diagnostic_function -- categories: -- -- EDAC, EEPROM, and FPGA(s). The FPGA category has 4 -- subtests one associated with FPGA1, two with FPGA2, and one -- with FPGA3. -- -- The MIB shall be used to configure the diagnostic tests -- to be run on each bank and read the results of the same. The -- selection of a particular bank to run the tests is hardware- -- dependent. -- -- GLOSSARY -- CLI - Command Line Interface -- diags - abbreviation for diagnostics -- EDAC - Error Detection and Correction -- EEPROM - Electrically Eraseable Programmable Read-Only Memory -- FPGA - Field Programmable Gate Array -- IOS - Internet Operating System -- MIB - Management Information Base -- NVRAM - Non-volatile Random Access Memory -- SRAM - Static Random Access Memory -- RevDate -- 200905120000Z -- RevDescr -- Initial version of this MIB module. ciscoBootHwDiagsMIBNotifs OBJECT IDENTIFIER ::= { ciscoBootHwDiagsMIB 0 } ciscoBootHwDiagsMIBObjects OBJECT IDENTIFIER ::= { ciscoBootHwDiagsMIB 1 } ciscoBootHwDiagsMIBConform OBJECT IDENTIFIER ::= { ciscoBootHwDiagsMIB 2 } ciscoBootHwDiagsMIBCompliances OBJECT IDENTIFIER ::= { ciscoBootHwDiagsMIBConform 1 } ciscoBootHwDiagsMIBGroups OBJECT IDENTIFIER ::= { ciscoBootHwDiagsMIBConform 2 } ciscoBootHwDiagsMIBCurrentBank OBJECT-TYPE SYNTAX Gauge(0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the current bank the device has booted with and executed the diagnostic tests." ::= { ciscoBootHwDiagsMIBObjects 1 } ciscoBootHwDiagsMIBTestTable OBJECT-TYPE SYNTAX SEQUENCE OF CiscoBootHwDiagsMIBTestEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table gives the list of possible diagnostic test 'categories' that may be configured, armed, and run for each bank. The categories are the same for all banks. In the CLI example given above, the categories are: EDAC test, EEPROM test, and FGPA(s) test." ::= { ciscoBootHwDiagsMIBObjects 2 } ciscoBootHwDiagsMIBTestEntry OBJECT-TYPE SYNTAX CiscoBootHwDiagsMIBTestEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry represents a row in ciscoBootHwDiagsMIBTestTable and corresponds to the information about the various categories of diagnostic tests." INDEX { ciscoBootHwDiagsMIBTestIndex } ::= { ciscoBootHwDiagsMIBTestTable 1 } CiscoBootHwDiagsMIBTestEntry ::= SEQUENCE { ciscoBootHwDiagsMIBTestIndex Gauge, ciscoBootHwDiagsMIBTestName DisplayString } ciscoBootHwDiagsMIBTestIndex OBJECT-TYPE SYNTAX Gauge ACCESS not-accessible STATUS mandatory DESCRIPTION "This object uniquely identifies the information about a particular category of test." ::= { ciscoBootHwDiagsMIBTestEntry 1 } ciscoBootHwDiagsMIBTestName OBJECT-TYPE SYNTAX DisplayString(SIZE(3..255)) -- Rsyntax OCTET STRING(SIZE(3..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the name of the diagnostic test." ::= { ciscoBootHwDiagsMIBTestEntry 2 } ciscoBootHwDiagsMIBTable OBJECT-TYPE SYNTAX SEQUENCE OF CiscoBootHwDiagsMIBEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table lists the configuration and results of the tests run on the banks. The results correspond to the execution of the respective tests run at the most recent boot of the device." ::= { ciscoBootHwDiagsMIBObjects 3 } ciscoBootHwDiagsMIBEntry OBJECT-TYPE SYNTAX CiscoBootHwDiagsMIBEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry represents a row in ciscoBootHwDiagsMIBTable and corresponds to the information about the diagnostic tests for a particular bank." INDEX { ciscoBootHwDiagsMIBBankIndex, ciscoBootHwDiagsMIBTestIndex } ::= { ciscoBootHwDiagsMIBTable 1 } CiscoBootHwDiagsMIBEntry ::= SEQUENCE { ciscoBootHwDiagsMIBBankIndex Gauge, ciscoBootHwDiagsMIBLastBootExecuted TruthValue, ciscoBootHwDiagsMIBLastBootPassed TruthValue, ciscoBootHwDiagsMIBNextBootConfigured TruthValue, ciscoBootHwDiagsMIBNextBootArmed TruthValue, ciscoBootHwDiagsMIBConfigCode Gauge, ciscoBootHwDiagsMIBResultCode Gauge } ciscoBootHwDiagsMIBBankIndex OBJECT-TYPE SYNTAX Gauge(0..1000) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object, together with ciscoBootHwDiagsMIBTestIndex, uniquely identifies the information about a particular diagnostic test." ::= { ciscoBootHwDiagsMIBEntry 1 } ciscoBootHwDiagsMIBLastBootExecuted OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the execution status of the test. A value of 'true' indicates that the test has been executed on the most recent boot of the device. A value of 'false' indicates that the test has not been executed." DEFVAL { false } ::= { ciscoBootHwDiagsMIBEntry 2 } ciscoBootHwDiagsMIBLastBootPassed OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the result of the test on the most recent boot of the device. A value of 'true' indicates that the test passed. A value of 'false' indicates that the test failed." ::= { ciscoBootHwDiagsMIBEntry 3 } ciscoBootHwDiagsMIBNextBootConfigured OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the action to be taken on this bank at the next boot. A value of 'true' indicates that the test identified by ciscoBootHwDiagsMIBTestName will be executed at the next boot, provided the device chooses this bank for diagnosis." DEFVAL { false } ::= { ciscoBootHwDiagsMIBEntry 4 } ciscoBootHwDiagsMIBNextBootArmed OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "A value of 'true' indicates that, for a particular numbered bank, all the configured tests for that same numbered bank are run." DEFVAL { false } ::= { ciscoBootHwDiagsMIBEntry 5 } ciscoBootHwDiagsMIBConfigCode OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "This object provides additional optional detailed configuration options (sub-tests configurations) for a diagnostics test category. The decoding of this unsigned 32-bit integer is platform-specific and allows for many platform-specific configurations. For the CLI example above, a ciscoBootHwDiagsMIBConfigCode for the FPGA(s) test category will cause all FPGA tests to be disabled, whereas, a ciscoBootHwDiagsMIBConfigCode of 1 will enable FPGA1 test. A ciscoBootHwDiagsMIBConfigCode of 3 will enable FPGA1 AND FPGA2-subtest1, and so forth (since there is only one test for FPGA1, but two tests for FPGA2). Hence the encoding is platform dependent and flexible." DEFVAL { 0 } ::= { ciscoBootHwDiagsMIBEntry 6 } ciscoBootHwDiagsMIBResultCode OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This object represents a return code that may be mapped to detailed testresults in an analogous way to how the ciscoBootHwDiagsMIBConfigCode is mapped to configurations. That is, for the CLI example above, a ciscoBootHwDiagsMIBResultCode of F (hex) indicates that all FPGA tests passed. A ciscoBootHwDiagsMIBResultCode of 1 (hex), indicates that ONLY FPGA1 test passed. A ciscoBootHwDiagsMIBResultCode of 3 (hex) indicates that only FPGA1 AND FPGA2-subtest1 passed, and so forth (since there is only one test for FPGA1, but two tests for FPGA2). Hence the encoding is platform dependent and flexible." ::= { ciscoBootHwDiagsMIBEntry 7 } ciscoBootHwDiagsMIBMainObjectGroup OBJECT IDENTIFIER ::= { ciscoBootHwDiagsMIBGroups 1 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group represents the information about the banks and the -- diagnostic tests run on them. -- objects -- ciscoBootHwDiagsMIBCurrentBank, ciscoBootHwDiagsMIBTestName, -- ciscoBootHwDiagsMIBLastBootExecuted, -- ciscoBootHwDiagsMIBLastBootPassed, -- ciscoBootHwDiagsMIBNextBootConfigured, -- ciscoBootHwDiagsMIBNextBootArmed, -- ciscoBootHwDiagsMIBConfigCode, ciscoBootHwDiagsMIBResultCode ciscoBootHwDiagsMIBCompliance OBJECT IDENTIFIER ::= { ciscoBootHwDiagsMIBCompliances 1 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- The compliance statement for the entities that implement the -- ciscoBootHwDiagsMIB module. -- Module -- >>current<< -- MandGroup -- ciscoBootHwDiagsMIBMainObjectGroup END