-- MIB file created 30-Apr-2007 13:27:57, by -- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com CISCO-CONFIG-MAN-MIB DEFINITIONS ::= BEGIN -- From file: "CISCO-CONFIG-MAN-MIB.my" -- Compile options "4 7 F H N O W 03 06 0B 0G 0N 0T" IMPORTS DisplayString, TruthValue, DateAndTime FROM SNMPv2-TC-v1 InetAddressType, InetAddress FROM INET-ADDRESS-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB Unsigned64 FROM CISCO-TC ciscoMgmt FROM CISCO-SMI Counter, Gauge, IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; ciscoConfigManMIB OBJECT IDENTIFIER ::= { ciscoMgmt 43 } -- MODULE-IDENTITY -- LastUpdated -- 200704270000Z -- OrgName -- Cisco Systems, Inc. -- ContactInfo -- Cisco Systems -- Customer Service -- -- -- Postal: 170 W Tasman Drive -- San Jose, CA 95134 -- USA -- -- Tel: +1 800 553-NETS -- -- E-mail: cs-snmp@cisco.com -- Descr -- Configuration management MIB. -- -- The MIB represents a model of configuration data that -- exists in various locations: -- -- running in use by the running system -- terminal saved to whatever is attached as the terminal -- local saved locally in NVRAM or flash -- remote saved to some server on the network -- -- Although some of the system functions that relate here -- can be used for general file storage and transfer, this -- MIB intends to include only such operations as clearly -- relate to configuration. Its primary emphasis is to -- track changes and saves of the running configuration. -- -- As saved data moves further from startup use, such as -- into different local flash files or onto the network, -- tracking becomes difficult to impossible, so the MIB's -- interest and functions are confined in that area. -- -- Information from ccmCLIHistoryCommandTable can be used -- to track the exact configuration changes that took -- place within a particular Configuration History -- event. NMS' can use this information to update -- the related components. -- For example: -- If commands related only to MPLS are entered -- then the NMS need to update only the MPLS related -- management information rather than updating -- all of its management information. -- Acronyms and terms: -- -- CLI Command Line Interface. -- RevDate -- 200704270000Z -- RevDescr -- Changes to definition of terminal as an output -- location. -- RevDate -- 200608170000Z -- RevDescr -- Added a new group of objects to store the information -- related to the Config Change Tracking ID (CTID) feature. -- -- CTID will provide a version number that is unique for -- version-incrementing changes to the IOS -- running-configuration. It will also provide information -- about when CTID last changed. -- -- Added scalars: -- * ccmCTID -- * ccmCTIDLastChangeTime -- * ccmCTIDWhoChanged -- * ccmCTIDRolledOverNotifEnable -- -- Added Notification: -- * ccmCTIDRolledOver -- -- Added Object Group: -- * ciscoConfigManCTIDObjectGroup -- -- Added Notification Group: -- * ciscoConfigManCTIDNotifyGroup -- -- Added Compliance: -- ciscoConfigManMIBComplianceRev4 -- RevDate -- 200406180000Z -- RevDescr -- The Objects ccmHistoryEventCommandSourceAddress and -- ccmHistoryEventServerAddress are deprecated since -- they support only IPv4 address. These objects have -- been replaced by two new objects -- ccmHistoryEventCommandSourceAddrRev1 and -- ccmHistoryEventServerAddrRev1. In addition to these -- objects two more new objects are defined -- ccmHistoryEventCommandSourceAddrType and -- ccmHistoryEventServerAddrType -- RevDate -- 200206070000Z -- RevDescr -- Added new enumerations networkFtp(8) and -- networkScp(9) to HistoryEventMedium. -- RevDate -- 200203120000Z -- RevDescr -- Added ccmCLIHistoryCommandTable for -- storing the CLI commands that took effect during -- a configuration event. -- -- Added scalars ccmCLIHistoryMaxCmdEntries -- ccmCLIHistoryCmdEntries and -- ccmCLIHistoryCmdEntriesAllowed. -- -- Added ccmHistoryCLICmdEntriesBumped to -- ccmHistoryEventTable to store the number of -- corresponding bumped entries in the -- ccmCLIHistoryCommandTable. -- -- Added the ccmCLIRunningConfigChanged notification. -- Added ccmCLICfgRunConfNotifEnable to control the -- ccmCLIRunningConfigChanged notification. -- -- Added notification group -- ciscoConfigManHistNotifyGroup. -- -- Updated the MIB description to indicate the use of -- the above additions. -- RevDate -- 9511280000Z -- RevDescr -- Initial version of this MIB module. ciscoConfigManMIBObjects OBJECT IDENTIFIER ::= { ciscoConfigManMIB 1 } ccmHistory OBJECT IDENTIFIER ::= { ciscoConfigManMIBObjects 1 } ccmCLIHistory OBJECT IDENTIFIER ::= { ciscoConfigManMIBObjects 2 } ccmCLICfg OBJECT IDENTIFIER ::= { ciscoConfigManMIBObjects 3 } ccmCTIDObjects OBJECT IDENTIFIER ::= { ciscoConfigManMIBObjects 4 } ciscoConfigManMIBNotificationPrefix OBJECT IDENTIFIER ::= { ciscoConfigManMIB 2 } ciscoConfigManMIBNotifications OBJECT IDENTIFIER ::= { ciscoConfigManMIBNotificationPrefix 0 } ciscoConfigManMIBConformance OBJECT IDENTIFIER ::= { ciscoConfigManMIB 3 } ciscoConfigManMIBCompliances OBJECT IDENTIFIER ::= { ciscoConfigManMIBConformance 1 } ciscoConfigManMIBGroups OBJECT IDENTIFIER ::= { ciscoConfigManMIBConformance 2 } HistoryEventMedium ::= INTEGER { erase(1), commandSource(2), running(3), startup(4), local(5), networkTftp(6), networkRcp(7), networkFtp(8), networkScp(9) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- The source or destination of a configuration change, -- save, or copy. -- -- erase erasing destination (source only) -- running live operational data -- commandSource the command source itself -- startup what the system will use next reboot -- local local NVRAM or flash -- networkTftp network host via Trivial File Transfer -- networkRcp network host via Remote Copy -- networkFtp network host via File transfer -- networkScp network host via Secure Copy ccmHistoryRunningLastChanged OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when the running configuration was last changed. If the value of ccmHistoryRunningLastChanged is greater than ccmHistoryRunningLastSaved, the configuration has been changed but not saved." ::= { ccmHistory 1 } ccmHistoryRunningLastSaved OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when the running configuration was last saved (written). If the value of ccmHistoryRunningLastChanged is greater than ccmHistoryRunningLastSaved, the configuration has been changed but not saved. What constitutes a safe saving of the running configuration is a management policy issue beyond the scope of this MIB. For some installations, writing the running configuration to a terminal may be a way of capturing and saving it. Others may use local or remote storage. Thus ANY write is considered saving for the purposes of the MIB." ::= { ccmHistory 2 } ccmHistoryStartupLastChanged OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when the startup configuration was last written to. In general this is the default configuration used when cold starting the system. It may have been changed by a save of the running configuration or by a copy from elsewhere." ::= { ccmHistory 3 } ccmHistoryMaxEventEntries OBJECT-TYPE SYNTAX INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of entries that can be held in ccmHistoryEventTable. The recommended value for implementations is 10." ::= { ccmHistory 4 } ccmHistoryEventEntriesBumped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the oldest entry in ccmHistoryEventTable was deleted to make room for a new entry." ::= { ccmHistory 5 } ccmHistoryEventTable OBJECT-TYPE SYNTAX SEQUENCE OF CcmHistoryEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of configuration events on this router." ::= { ccmHistory 6 } ccmHistoryEventEntry OBJECT-TYPE SYNTAX CcmHistoryEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about a configuration event on this router." INDEX { ccmHistoryEventIndex } ::= { ccmHistoryEventTable 1 } CcmHistoryEventEntry ::= SEQUENCE { ccmHistoryEventIndex INTEGER, ccmHistoryEventTime TimeTicks, ccmHistoryEventCommandSource INTEGER, ccmHistoryEventConfigSource HistoryEventMedium, ccmHistoryEventConfigDestination HistoryEventMedium, ccmHistoryEventTerminalType INTEGER, ccmHistoryEventTerminalNumber INTEGER, ccmHistoryEventTerminalUser DisplayString, ccmHistoryEventTerminalLocation DisplayString, ccmHistoryEventCommandSourceAddress IpAddress, ccmHistoryEventVirtualHostName DisplayString, ccmHistoryEventServerAddress IpAddress, ccmHistoryEventFile DisplayString, ccmHistoryEventRcpUser DisplayString, ccmHistoryCLICmdEntriesBumped Counter, ccmHistoryEventCommandSourceAddrType InetAddressType, ccmHistoryEventCommandSourceAddrRev1 InetAddress, ccmHistoryEventServerAddrType InetAddressType, ccmHistoryEventServerAddrRev1 InetAddress } ccmHistoryEventIndex OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS not-accessible STATUS mandatory DESCRIPTION "A monotonically increasing integer for the sole purpose of indexing events. When it reaches the maximum value, an extremely unlikely event, the agent wraps the value back to 1 and may flush existing entries." ::= { ccmHistoryEventEntry 1 } ccmHistoryEventTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when the event occurred." ::= { ccmHistoryEventEntry 2 } ccmHistoryEventCommandSource OBJECT-TYPE SYNTAX INTEGER { commandLine(1), snmp(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The source of the command that instigated the event." ::= { ccmHistoryEventEntry 3 } ccmHistoryEventConfigSource OBJECT-TYPE SYNTAX HistoryEventMedium -- Rsyntax INTEGER { -- erase(1), -- commandSource(2), -- running(3), -- startup(4), -- local(5), -- networkTftp(6), -- networkRcp(7), -- networkFtp(8), -- networkScp(9) -- } ACCESS read-only STATUS mandatory DESCRIPTION "The configuration data source for the event." ::= { ccmHistoryEventEntry 4 } ccmHistoryEventConfigDestination OBJECT-TYPE SYNTAX HistoryEventMedium -- Rsyntax INTEGER { -- erase(1), -- commandSource(2), -- running(3), -- startup(4), -- local(5), -- networkTftp(6), -- networkRcp(7), -- networkFtp(8), -- networkScp(9) -- } ACCESS read-only STATUS mandatory DESCRIPTION "The configuration data destination for the event." ::= { ccmHistoryEventEntry 5 } ccmHistoryEventTerminalType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), unknown(2), console(3), terminal(4), virtual(5), auxiliary(6) } ACCESS read-only STATUS mandatory DESCRIPTION "If ccmHistoryEventCommandSource is 'commandLine', the terminal type, otherwise 'notApplicable'." ::= { ccmHistoryEventEntry 6 } ccmHistoryEventTerminalNumber OBJECT-TYPE SYNTAX INTEGER(-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "If ccmHistoryEventCommandSource is 'commandLine', the terminal number. The value is -1 if not available or not applicable." ::= { ccmHistoryEventEntry 7 } ccmHistoryEventTerminalUser OBJECT-TYPE SYNTAX DisplayString(SIZE(0..64)) -- Rsyntax OCTET STRING(SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "If ccmHistoryEventCommandSource is 'commandLine', the name of the logged in user. The length is zero if not available or not applicable." ::= { ccmHistoryEventEntry 8 } ccmHistoryEventTerminalLocation OBJECT-TYPE SYNTAX DisplayString(SIZE(0..64)) -- Rsyntax OCTET STRING(SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "If ccmHistoryEventCommandSource is 'commandLine', the hard-wired location of the terminal or the remote host for an incoming connection. The length is zero if not available or not applicable." ::= { ccmHistoryEventEntry 9 } ccmHistoryEventCommandSourceAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS deprecated DESCRIPTION "If ccmHistoryEventTerminalType is 'virtual', the internet address of the connected system. If ccmHistoryEventCommandSource is 'snmp', the internet address of the requester. The value is 0.0.0.0 if not available or not applicable. This object is deprecated by ccmHistoryEventCommandSourceAddrRev1" ::= { ccmHistoryEventEntry 10 } ccmHistoryEventVirtualHostName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..64)) -- Rsyntax OCTET STRING(SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "If ccmHistoryEventTerminalType is 'virtual', the host name of the connected system. The length is zero if not available or not applicable." ::= { ccmHistoryEventEntry 11 } ccmHistoryEventServerAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS deprecated DESCRIPTION "If ccmHistoryEventConfigSource or ccmHistoryEventConfigDestination is 'networkTftp' or 'networkRcp', the internet address of the storage file server. The value is 0.0.0.0 if not applicable or not available. This object is deprecated by ccmHistoryEventServerAddrRev1" ::= { ccmHistoryEventEntry 12 } ccmHistoryEventFile OBJECT-TYPE SYNTAX DisplayString(SIZE(0..64)) -- Rsyntax OCTET STRING(SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "If ccmHistoryEventConfigSource or ccmHistoryEventConfigDestination is 'networkTftp' or 'networkRcp', the configuration file name at the storage file server. The length is zero if not available or not applicable." ::= { ccmHistoryEventEntry 13 } ccmHistoryEventRcpUser OBJECT-TYPE SYNTAX DisplayString(SIZE(0..64)) -- Rsyntax OCTET STRING(SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "If ccmHistoryEventConfigSource or ccmHistoryEventConfigDestination is 'networkRcp', the remote user name. The length is zero if not applicable or not available." ::= { ccmHistoryEventEntry 14 } ccmHistoryCLICmdEntriesBumped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the oldest entry in ccmCLIHistoryCommandTable with first index as ccmHistoryEventIndex was deleted to make room for a new entry. This object is applicable only if ccmHistoryEventCommandSource has a value of 'commandLine'." ::= { ccmHistoryEventEntry 15 } ccmHistoryEventCommandSourceAddrType OBJECT-TYPE SYNTAX InetAddressType -- Rsyntax INTEGER { -- ?? enum value of zero may cause problems -- unknown(0), -- ipv4(1), -- ipv6(2), -- ipv4z(3), -- ipv6z(4), -- dns(16) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the transport type of the address contained in ccmHistoryEventCommandSourceAddrRev1. The value will be zero if not available or not applicable." ::= { ccmHistoryEventEntry 16 } ccmHistoryEventCommandSourceAddrRev1 OBJECT-TYPE SYNTAX InetAddress -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "If ccmHistoryEventTerminalType is 'virtual', the internet address of the connected system. If ccmHistoryEventCommandSource is 'snmp', the internet address of the requester. The value of all bit's is zero if not available or not applicable. The Format of this address depends on the value of the ccmHistoryEventCommandSourceAddrType object. This object deprecates ccmHistoryEventCommandSourceAddress" ::= { ccmHistoryEventEntry 17 } ccmHistoryEventServerAddrType OBJECT-TYPE SYNTAX InetAddressType -- Rsyntax INTEGER { -- ?? enum value of zero may cause problems -- unknown(0), -- ipv4(1), -- ipv6(2), -- ipv4z(3), -- ipv6z(4), -- dns(16) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the transport type of the address contained in ccmHistoryEventServerAddrRev1. The value will be zero if not available or not aplicable." ::= { ccmHistoryEventEntry 18 } ccmHistoryEventServerAddrRev1 OBJECT-TYPE SYNTAX InetAddress -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "If ccmHistoryEventConfigSource or ccmHistoryEventConfigDestination is 'networkTftp' or 'networkRcp', the internet address of the storage file server. The value of all bits is 0s if not applicable or not available. The Format of this address depends on the value of the ccmHistoryEventServerAddrType object. This object deprecates ccmHistoryEventServerAddress." ::= { ccmHistoryEventEntry 19 } ccmCLIHistoryMaxCmdEntries OBJECT-TYPE SYNTAX Gauge(0..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of entries that can be held in ccmCLIHistoryCommandTable. The recommended value for implementations is 100. If the number of entries in ccmCLIHistoryCommandTable exceeds the value of this object, old entries will be bumped to make room for new entries. The ccmCLIHistoryCommandTable will not be populated if the value of this object is 0." ::= { ccmCLIHistory 1 } ccmCLIHistoryCmdEntries OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The current number of entries in ccmCLIHistoryCommandTable." ::= { ccmCLIHistory 2 } ccmCLIHistoryCmdEntriesAllowed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the upper limit on the number of entries allowed in ccmCLIHistoryCommandTable by the managed system." ::= { ccmCLIHistory 3 } ccmCLIHistoryCommandTable OBJECT-TYPE SYNTAX SEQUENCE OF CcmCLIHistoryCommandEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of CLI commands that took effect during configuration events." ::= { ccmCLIHistory 4 } ccmCLIHistoryCommandEntry OBJECT-TYPE SYNTAX CcmCLIHistoryCommandEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about the CLI commands that took effect during the configuration event pointed by ccmCLIHistoryEventIndex. A set of rows in this table having the first index as ccmHistoryEventIndex will store the CLI commands entered during the corresponding configuration event in ccmHistoryEventTable. An entry will be created in this table only if the corresponding entry in ccmHistoryEventTable has a value of 'commandLine' for ccmHistoryEventCommandSource." INDEX { ccmHistoryEventIndex, ccmCLIHistoryCommandIndex } ::= { ccmCLIHistoryCommandTable 1 } CcmCLIHistoryCommandEntry ::= SEQUENCE { ccmCLIHistoryCommandIndex Gauge, ccmCLIHistoryCommand DisplayString } ccmCLIHistoryCommandIndex OBJECT-TYPE SYNTAX Gauge(1..4294967295) ACCESS not-accessible STATUS mandatory DESCRIPTION "A monotonically increasing integer for the purpose of indexing CLI commands which took effect during a configuration event." ::= { ccmCLIHistoryCommandEntry 1 } ccmCLIHistoryCommand OBJECT-TYPE SYNTAX DisplayString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The CLI command entered which took effect during the configuration event pointed by ccmHistoryEventIndex." ::= { ccmCLIHistoryCommandEntry 2 } ccmCLICfgRunConfNotifEnable OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This variable indicates whether the system produces the ccmCLIRunningConfigChanged notification. A false value will prevent notifications from being generated by this system." DEFVAL { false } ::= { ccmCLICfg 1 } ccmCTID OBJECT-TYPE SYNTAX --?? syntax is not convertable to SMIv1 Unsigned64 -- Rsyntax Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the Config Change Tracking ID which uniquely represents version-incrementing changes to the IOS running configuration." ::= { ccmCTIDObjects 1 } ccmCTIDLastChangeTime OBJECT-TYPE SYNTAX DateAndTime -- Rsyntax OCTET STRING(SIZE(8|11)) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the time when the Config Change Tracking ID last changed." ::= { ccmCTIDObjects 2 } ccmCTIDWhoChanged OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the user who last reset the Config Change Tracking ID." ::= { ccmCTIDObjects 3 } ccmCTIDRolledOverNotifEnable OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This variable indicates whether the system produces the ccmCTIDRolledOver notification. A false value will prevent notifications from being generated by this system." DEFVAL { false } ::= { ccmCTIDObjects 4 } ciscoConfigManEvent TRAP-TYPE -- Reverse mappable trap ENTERPRISE ciscoConfigManMIBNotificationPrefix VARIABLES { ccmHistoryEventCommandSource, ccmHistoryEventConfigSource, ccmHistoryEventConfigDestination } -- Status -- mandatory DESCRIPTION "Notification of a configuration management event as recorded in ccmHistoryEventTable." ::= 1 ccmCLIRunningConfigChanged TRAP-TYPE -- Reverse mappable trap ENTERPRISE ciscoConfigManMIBNotificationPrefix VARIABLES { ccmHistoryRunningLastChanged, ccmHistoryEventTerminalType } -- Status -- mandatory DESCRIPTION "This notification indicates that the running configuration of the managed system has changed from the CLI. If the managed system supports a separate configuration mode(where the configuration commands are entered under a configuration session which affects the running configuration of the system), then this notification is sent when the configuration mode is exited. During this configuration session there can be one or more running configuration changes." ::= 2 ccmCTIDRolledOver TRAP-TYPE -- Reverse mappable trap ENTERPRISE ciscoConfigManMIBNotificationPrefix -- Status -- mandatory DESCRIPTION "This notification indicates that the Config Change Tracking ID has rolled over and will be reset." ::= 3 ciscoConfigManHistoryGroup OBJECT IDENTIFIER ::= { ciscoConfigManMIBGroups 1 } -- OBJECT-GROUP -- Status -- deprecated -- Descr -- Configuration history. -- objects -- ccmHistoryRunningLastChanged, ccmHistoryRunningLastSaved, -- ccmHistoryStartupLastChanged, ccmHistoryMaxEventEntries, -- ccmHistoryEventEntriesBumped, ccmHistoryEventTime, -- ccmHistoryEventCommandSource, ccmHistoryEventConfigSource, -- ccmHistoryEventConfigDestination, ccmHistoryEventTerminalType, -- ccmHistoryEventTerminalNumber, ccmHistoryEventTerminalUser, -- ccmHistoryEventTerminalLocation, -- ccmHistoryEventCommandSourceAddress, -- ccmHistoryEventVirtualHostName, ccmHistoryEventServerAddress, -- ccmHistoryEventFile, ccmHistoryEventRcpUser ciscoConfigManHistoryGroupRev1 OBJECT IDENTIFIER ::= { ciscoConfigManMIBGroups 2 } -- OBJECT-GROUP -- Status -- deprecated -- Descr -- Configuration history. -- objects -- ccmHistoryRunningLastChanged, ccmHistoryRunningLastSaved, -- ccmHistoryStartupLastChanged, ccmHistoryMaxEventEntries, -- ccmHistoryEventEntriesBumped, ccmHistoryEventTime, -- ccmHistoryEventCommandSource, ccmHistoryEventConfigSource, -- ccmHistoryEventConfigDestination, ccmHistoryEventTerminalType, -- ccmHistoryEventTerminalNumber, ccmHistoryEventTerminalUser, -- ccmHistoryEventTerminalLocation, -- ccmHistoryEventCommandSourceAddress, -- ccmHistoryEventVirtualHostName, ccmHistoryEventServerAddress, -- ccmHistoryEventFile, ccmHistoryEventRcpUser, -- ccmHistoryCLICmdEntriesBumped ciscoConfigManHistoryGroupRev2 OBJECT IDENTIFIER ::= { ciscoConfigManMIBGroups 5 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Configuration history. -- -- This group deprecates the old group -- ciscoConfigManHistoryGroupRev1 -- objects -- ccmHistoryRunningLastChanged, ccmHistoryRunningLastSaved, -- ccmHistoryStartupLastChanged, ccmHistoryMaxEventEntries, -- ccmHistoryEventEntriesBumped, ccmHistoryEventTime, -- ccmHistoryEventCommandSource, ccmHistoryEventConfigSource, -- ccmHistoryEventConfigDestination, ccmHistoryEventTerminalType, -- ccmHistoryEventTerminalNumber, ccmHistoryEventTerminalUser, -- ccmHistoryEventTerminalLocation, -- ccmHistoryEventVirtualHostName, ccmHistoryEventFile, -- ccmHistoryEventRcpUser, ccmHistoryCLICmdEntriesBumped, -- ccmHistoryEventCommandSourceAddrType, -- ccmHistoryEventCommandSourceAddrRev1, -- ccmHistoryEventServerAddrType, ccmHistoryEventServerAddrRev1 ciscoConfigManCLIHistCmdGroup OBJECT IDENTIFIER ::= { ciscoConfigManMIBGroups 4 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- CLI commands entered during a configuration history -- event. -- objects -- ccmCLIHistoryMaxCmdEntries, ccmCLIHistoryCmdEntries, -- ccmCLIHistoryCmdEntriesAllowed, ccmCLIHistoryCommand, -- ccmCLICfgRunConfNotifEnable ciscoConfigManCTIDObjectGroup OBJECT IDENTIFIER ::= { ciscoConfigManMIBGroups 7 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Information about the current CTID value, when CTID last -- changed, and who last changed the CTID. -- objects -- ccmCTID, ccmCTIDLastChangeTime, ccmCTIDWhoChanged, -- ccmCTIDRolledOverNotifEnable ciscoConfigManHistNotifyGroup OBJECT IDENTIFIER ::= { ciscoConfigManMIBGroups 3 } -- NOTIFICATION-GROUP -- Status -- mandatory -- Descr -- Notifications of a configuration management event. -- notifications -- ciscoConfigManEvent, ccmCLIRunningConfigChanged ciscoConfigManCTIDNotifyGroup OBJECT IDENTIFIER ::= { ciscoConfigManMIBGroups 6 } -- NOTIFICATION-GROUP -- Status -- mandatory -- Descr -- Notifications of a Config Change Tracking ID event. -- notifications -- ccmCTIDRolledOver ciscoConfigManMIBCompliance OBJECT IDENTIFIER ::= { ciscoConfigManMIBCompliances 1 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- The compliance statement for entities which implement -- the Cisco Configuration Management MIB -- Module -- >>current<< -- MandGroup -- ciscoConfigManHistoryGroup ciscoConfigManMIBComplianceRev2 OBJECT IDENTIFIER ::= { ciscoConfigManMIBCompliances 2 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- The compliance statement for entities which implement -- the Cisco Configuration Management MIB -- Module -- >>current<< -- MandGroup -- ciscoConfigManHistoryGroupRev1 -- OptGroup -- ciscoConfigManCLIHistCmdGroup -- OptGroup -- ciscoConfigManHistNotifyGroup ciscoConfigManMIBComplianceRev3 OBJECT IDENTIFIER ::= { ciscoConfigManMIBCompliances 3 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- The compliance statement for entities which implement -- the Cisco Configuration Management MIB. -- -- This compliance module deprecates -- ciscoConfigManMIBCompliance. -- Module -- >>current<< -- MandGroup -- ciscoConfigManHistoryGroupRev2 -- OptGroup -- ciscoConfigManCLIHistCmdGroup -- OptGroup -- ciscoConfigManHistNotifyGroup ciscoConfigManMIBComplianceRev4 OBJECT IDENTIFIER ::= { ciscoConfigManMIBCompliances 4 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- The compliance statement for entities which implement -- the Cisco Configuration Management MIB. -- -- This compliance module deprecates -- ciscoConfigManMIBCompliance. -- Module -- >>current<< -- MandGroup -- ciscoConfigManHistoryGroupRev2 -- OptGroup -- ciscoConfigManCLIHistCmdGroup -- OptGroup -- ciscoConfigManHistNotifyGroup -- OptGroup -- ciscoConfigManCTIDNotifyGroup -- OptGroup -- ciscoConfigManCTIDObjectGroup END