-- MIB file created 12-Jul-2010 10:11:26, by -- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com CISCO-ENERGYWISE-MIB DEFINITIONS ::= BEGIN -- From file: "CISCO-ENERGYWISE-MIB.my" -- Compile options "4 7 F H N W 03 06 0B 0G 0N 0T" IMPORTS RowStatus, TruthValue, StorageType, TimeStamp, MacAddress FROM SNMPv2-TC-v1 InetAddress, InetAddressType, InetPortNumber FROM INET-ADDRESS-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB entPhysicalIndex, entityMIBObjects FROM ENTITY-MIB EntPhysicalIndexOrZero FROM CISCO-TC ciscoMgmt FROM CISCO-SMI Counter, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; ciscoEnergywiseMIB OBJECT IDENTIFIER ::= { ciscoMgmt 683 } -- MODULE-IDENTITY -- LastUpdated -- 201007090000Z -- OrgName -- Cisco Systems, Inc. -- ContactInfo -- Cisco Systems -- Customer Service -- -- Postal: 170 W Tasman Drive -- San Jose, CA 95134 -- USA -- -- Tel: +1 800 553-NETS -- -- E-mail: cs-snmp@cisco.com -- Descr -- The MIB is used to manage and optimize power usage -- in networks. -- -- Cisco EnergyWise is a specification of data, discovery and -- protocols for managing power on and between network devices. -- -- An entity is Cisco EnergyWise compatible, if it complies with -- Cisco EnergyWise specification. -- -- A Cisco EnergyWise entity is characterized by the power related -- attributes of a physical entity present in ENTITY-MIB. -- -- Cisco EnergyWise solves the problem of Network Power -- Management. One of goals of Cisco EnergyWise is to manage -- power on network level. Some solutions in FCAPS have focused -- on -- managing a single element but Cisco EnergyWise provides the -- capability to handle the management of a network of devices, as -- well as a single device. -- -- Concepts and Definitions: -- ========================= -- Cisco EnergyWise Entity: A physical entity that is part of the -- network that provides power or draws power from another -- part of the network. -- -- Cisco EnergyWise Level: A uniform way to classify power -- settings on an EnergyWise entity. Levels are guidelines for -- the manufacturers of entity (e.g., shut, hibernate, sleep, -- standby). -- -- Cisco EnergyWise Usage: The consumption of power by a Cisco -- EnergyWise entity in watts. -- -- Current The current power consumption by an -- Cisco EnergyWise entity. -- -- Provisioned The maximum power a Cisco EnergyWise -- entity can draw in the current level. -- -- Usage Vector A vector 0..10 representing the maximum -- power a Cisco EnergyWise entity can draw at -- each level. -- -- Delta Vector This defines a vector 0..10 representing -- the difference between the Current and -- Usage Vector for each level. -- -- Cisco EnergyWise Entity Power Unit: This is used to represent -- smaller or larger quantities of Cisco EnergyWise usage and -- conforms to the standard prefixes for the SI (System -- International) units of measure. The value represents an -- exponent of 10. -- -- For example, if current usage of an EnergyWise entity is -- 3, it could be 3 W, 3 mW, 3 KW, 3 MW depending on the value -- of Cisco EnergyWise power unit, i.e. 0, -3, 3, or 6 -- respectively. -- -- Cisco EnergyWise Domain: A collection of entities that is -- divided into manageable sets. Switch, IP phones, IP cameras, -- lighting controllers can be Cisco EnergyWise entities, all part -- of a domain. A domain can contain multiple devices. -- -- Cisco EnergyWise Entity Importance: The importance attribute of -- an entity enables the management station to differentiate other -- Cisco EnergyWise entities in the domain with a different -- business context. This also provides a choice to the -- administrators to manage power in context of importance. -- -- For example, assuming we have 2 phones deployed in a -- enterprise. One phone is in a shared spare office and one -- used by trader generating lot of money as part of core -- business of enterprise. -- -- This clearly demonstrates that the phone used by trader is -- more important than the phone used in the spare office. -- -- Nanny Vector: A vector of bits, representing different features -- (E.g., sleep, wakeup, shutdown) supported on a Cisco -- EnergyWise entity. Setting of some of the features on the -- Cisco EnergyWise entity can be managed by itself, but for some -- others, a parent has to nanny. -- -- Nanny: An EnergyWise entity acts on behalf of another -- another Cisco EnergyWise entity. -- -- Cisco EnergyWise Parent: A Cisco EnergyWise entity that does -- not have a nanny vector. This entity can manage all its power -- setting for itself as well as for Cisco EnergyWise entities -- contained in it. The contained in relationship is same as -- defined in ENTITY-MIB. -- -- Cisco EnergyWise Child: A Cisco EnergyWise entity that has a -- nanny vector. It requires a Cisco EnergyWise parent to serve -- as nanny. Depending on the nanny vector a Cisco EnergyWise -- child can be fully or partially managed. -- -- Cisco EnergyWise Neighbor: A Cisco EnergyWise entity to which -- Cisco EnergyWise protocol events can be forwarded to. An -- entity can either discover a neighbor using a discovery -- protocol, or the neighbor can be configured as a static -- neighbor -- by the Management station. A Cisco EnergyWise parent may also -- nanny a Cisco EnergyWise neighbor. -- -- For example, A Cisco EnergyWise compatible entity like an -- IP phone, connected to a port on the switch, can provide a -- nanny vector to the switch to serve as a nanny. -- -- Cisco EnergyWise Proxy: A device attached to a port that does -- not understand the Cisco EnergyWise protocol, but has the -- provision to manage power through network APIs or a proprietary -- protocol. -- -- A Proxy is always configured on a port. It allows the -- Cisco EnergyWise protocol to be used with other non networking -- devices that draw power indirectly. -- -- For example, a Lutron controller (building lighting -- controller) is a nonnetworking device which does not -- understand Cisco EnergyWise protocol. However, it runs a -- proprietary BACNET protocol. -- -- The following diagram represents the relationship between -- cewEntTable and cewNeighborTable, -- cewEntTable and cewProxyTable. -- -- -- Points to a -- ===================== nbr entry for ===================== -- | EntPhyIdx | NbrId | which it does | NbrId | Name | -- ===================== Nanny ===================== -- | 101 | 1 |=================>| 1 | IP-Phone1 | -- ===================== ===================== -- | 102 | 0 | | 2 | Switch1 | -- ===================== ===================== -- | 103 | 3 |=================>| 3 | IP-Phone2 | -- ===================== ===================== -- | 104 | 0 |========== | | | -- ===================== | ===================== -- | 105 | 0 |===== | | | | -- ===================== | | ===================== -- | | -- Points to proxy | | ============================= -- entry configured | | | EntPhyIdx | PrxyId | Name | -- on this port. | | ============================= -- | |==>| 104 | 1 | LC1 | -- | ============================= -- | | | | | -- | ============================= -- =======> | 105 | 3 | BL2 | -- ============================= -- | | | | -- ============================= -- -- Cisco EnergyWise Event: It is a policy that can be either -- configured on a Cisco EnergyWise entity or received from -- other Cisco EnergyWise entities. Using this, a Cisco -- EnergyWise entity can adjust its power settings according -- to some criteria, typically time. -- -- For example, a Management station can configure an -- EnergyWise event on a switch to control devices in branch -- offices, to go to power level standby at 8pm and power -- level full at 7am. -- -- Cisco Energywise Query: It is a Cisco Energywise CLI used to -- get -- power information from the entire Energywise Domain. Queries -- are -- delivered, hop by hop, through the Domain using the established -- neighbor information. Authentication is by the domain's shared -- secret, and only authenticated queries can be sent to -- EndPoints. EnergyWise supports various kinds of queries, -- including set, collect, sum and delta. -- set: changes or turns off power usage levels -- collect: retrieves power usage information (in watts) from -- the cloud. -- sum: aggregates power information across multiple Members -- and Endpoints. -- delta: runs what if calculations. -- -- Cisco EnergyWise Neighbor Id : The Cisco EnergyWise Neighbor's -- unique Id is made up of two parts:- -- UDI: Unique Device Indentification of the Cisco EnergyWise -- Neighbor. -- EntPhysicalIndex: The Entity Physical Index of the Cisco -- EnergyWise Neighbor. -- A combination of these two values provide a unique Id for the -- Cisco EnergyWise Neighbor. -- RevDate -- 201007090000Z -- RevDescr -- Swaped the order of objects in cewEntEnergyUsageDirection and -- cewNeighborUsageDirection -- RevDate -- 201003260000Z -- RevDescr -- The following MIB objects have been added :- -- cewNeighborMacAddress -- cewNeighborParentPortIndex -- cewNeighborEnergywiseIdIndex -- -- Changed MAX-ACCESS for cewEntEnergyLevel to read-only to -- correct -- error were MIB did not match design and implementation. -- RevDate -- 200911220000Z -- RevDescr -- Two new mib objects have been added :- cewEntAllowSet and -- cewEntActivityCheck. -- RevDate -- 200910210000Z -- RevDescr -- The following MIB objects have been added :- -- -- cewEntEnergyUsageCategory -- cewEntEnergyUsageDirection -- -- cewNeighborKeyword -- cewNeighborConfiguredKeyword -- cewNeighborName -- cewNeighborConfiguredName -- cewNeighborRoleDescription -- cewNeighborConfiguredRoleDescription -- cewNeighborEnergyLevel -- cewNeighborConfiguredLevel -- cewNeighborImportance -- cewNeighborConfiguredImportance -- cewNeighborEnergyUnits -- cewNeighborEnergyUsage -- cewNeighborEnergyUsageCategory -- cewNeighborEnergyUsageDirection -- -- cewNeighborLevelTable :- -- -- cewNeighborLevelEntry -- cewNeighborLevelIndex -- cewNeighborLevelMaxUsage -- cewNeighborLevelDeltaUsage -- cewNeighborLevelUnits -- RevDate -- 200905200000Z -- RevDescr -- Following object was added to the MIB. -- -- cewDeviceType -- -- Following modifications were made -- -- cewNeighborDeviceType was added cewNeighborTable -- RevDate -- 200905080000Z -- RevDescr -- Following objects were added to the MIB to provide -- support for activation of Cisco EnergyWise on a Cisco -- EnergyWise entity. -- -- cewManagementSecret -- cewEndPointSecret -- cewDomainSecret -- cewProtocol -- cewAddressType -- cewAddress -- cewPort -- cewEnable -- cewVersion -- cewDeviceTotalUsage -- cewDeviceTotalUsageUnits -- -- Following modifications were made -- -- cewEntConfiguredlevel added to cewEntTable. -- cewEventImportance added to cewEventTable. -- RevDate -- 200901080000Z -- RevDescr -- Initial version of this MIB module. ciscoEnergywiseMIBNotifs OBJECT IDENTIFIER ::= { ciscoEnergywiseMIB 0 } ciscoEnergywiseMIBObjects OBJECT IDENTIFIER ::= { ciscoEnergywiseMIB 1 } ciscoEnergywiseMIBConform OBJECT IDENTIFIER ::= { ciscoEnergywiseMIB 2 } ciscoEnergywiseMIBCompliances OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBConform 1 } ciscoEnergywiseMIBGroups OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBConform 2 } EnergywiseLevel ::= INTEGER { shut(1), hibernate(2), sleep(3), standby(4), ready(5), low(6), frugal(7), medium(8), reduced(9), high(10), full(11) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- An enumerated integer value that represents the value of -- Cisco EnergyWise entity level, a power setting at which a Cisco -- EnergyWise entity uses power. -- -- shut(1) : An off state. No entity features are -- available. The entity is unavailable. -- No power is being consumed. -- -- hibernate(2): No entity features are available. The -- entity may be available but the time for -- availability is longer than sleep. Minimal, -- nearly zero, or zero power is consumed. -- -- sleep(3) : No entity features are available. The -- entity may be available but the time for -- availability is longer than standby. -- Minimal power is consumed. -- -- standby(4) : Indicates some entity features may not be -- available. The entity may be available -- but the time for availability is longer -- than ready. Minimal power is consumed. -- -- ready(5) : Indicates some entity features may not -- be available. The entity itself may be -- available but their may be a time delay -- for availability. -- Low or less power is consumed. -- -- low(6) : Indicates some features may not be available -- and the entity has taken measures/options to -- provide less than frugal usage. -- -- frugal(7) : Indicates some features may not be available -- and the entity has taken measures/options to -- provide less than medium usage. -- -- medium(8) : Indicates all entity features are available -- but the entity has taken measures/options to -- provide less than reduced usage. -- -- reduced(9) : Indicates all entity features are available -- but the entity has taken measures/options to -- provide less than high usage. -- -- high(10) : Indicates all entity features are available -- and power consumption is less than full. -- -- full(11) : Indicates all entity features are available -- and the entity is consuming the highest -- power. EnergywiseId ::= OCTET STRING(SIZE(0..32)) -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- A unique identifier for the Cisco EnergyWise entity in the -- Cisco EnergyWise domain. Implementation must make sure that the -- ID for each entity should be unique among all entities within -- the Cisco EnergyWise domain. -- -- For example, for Cisco entities, ID is based on UDI. -- where UDI consists of: -- PID - Product Identifier -- VID - Version Identifier -- SN - Serial Number. EnergywisePowerUnits ::= INTEGER(-24..24) -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- An integer value that represents the units used to measure -- the power. The units are expressed in watts. EnergywiseKeywordList ::= OCTET STRING(SIZE(0..255)) -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- A list of keywords. If multiple keywords are present, then -- this string will contain all the keywords separated by ',' -- character. -- -- For example, If a Cisco EnergyWise entity is tagged with -- keywords 'building' and 'lobby', then the keyword list -- will be 'building,lobby'. cewDeviceId OBJECT-TYPE SYNTAX EnergywiseId -- Rsyntax OCTET STRING(SIZE(0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the Cisco EnergyWise identifier assigned to the device." ::= { ciscoEnergywiseMIBObjects 1 } cewDeviceNeighborCount OBJECT-TYPE SYNTAX Gauge -- Units -- neighbors ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the current number of neighbors." ::= { ciscoEnergywiseMIBObjects 2 } cewDomainName OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the domain name of the Cisco EnergyWise entity. This object specifies a null string if no domain name is configured. If write access is implemented for an instance of cewDomainName, and a value is written into the instance, the agent must retain the supplied value in the cewDomainName instance associated with the same physical entity for as long as that entity remains instantiated. This includes instantiations across all re-initializations/reboots of the network management system, including those which result in a change of the physical entity's entPhysicalIndex value." ::= { ciscoEnergywiseMIBObjects 3 } cewMaxImportance OBJECT-TYPE SYNTAX Gauge -- Units -- importance ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the maximum importance value among all the Cisco EnergyWise entities in the domain." ::= { ciscoEnergywiseMIBObjects 4 } cewMaxImportanceId OBJECT-TYPE SYNTAX EnergywiseId -- Rsyntax OCTET STRING(SIZE(0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the Cisco EnergyWise identifier of the Cisco EnergyWise entity having maximum importance in the domain." ::= { ciscoEnergywiseMIBObjects 5 } cewEntTable OBJECT-TYPE SYNTAX SEQUENCE OF CewEntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table lists Cisco EnergyWise entities. This table has a sparse dependent relationship on the entPhysicalTable, where this table contains a row for each physical entity that is Cisco EnergyWise compliant." ::= { ciscoEnergywiseMIBObjects 6 } cewEntEntry OBJECT-TYPE SYNTAX CewEntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry describes attributes of a Cisco EnergyWise entity. Whenever the device creates/destroys a Cisco EnergyWise compliant entity, the device creates/destroys a row in the cewEntTable." INDEX { entPhysicalIndex } ::= { cewEntTable 1 } CewEntEntry ::= SEQUENCE { cewEntNannyVector OCTET STRING, cewEntNeighborIndex Gauge, cewEntKeyword EnergywiseKeywordList, cewEntName SnmpAdminString, cewEntRoleDescription SnmpAdminString, cewEntFullName SnmpAdminString, cewEntEnergyUnits EnergywisePowerUnits, cewEntEnergyUsage Gauge, cewEntEnergyUsageCaliber INTEGER, cewEntEnergyLevel EnergywiseLevel, cewEntEnergyUsageProvisioned Gauge, cewEntImportanceInt Gauge, cewEntImportanceExt Gauge, cewEntImportanceRelative Gauge, cewEntImportanceParentId EnergywiseId, cewEntParentId EnergywiseId, cewEntAdminStatus INTEGER, cewEntOperStatus INTEGER, cewEntConfiguredLevel EnergywiseLevel, cewEntEnergyUsageCategory INTEGER, cewEntEnergyUsageDirection INTEGER, cewEntAllowSet TruthValue, cewEntActivityCheck TruthValue } cewEntNannyVector OBJECT-TYPE SYNTAX OCTET STRING(SIZE(1..2)) -- BITS are: -- powerWakeUp(0) -- powerLevel1(1) -- powerLevel2(2) -- powerLevel3(3) -- powerLevel4(4) -- powerLevel5(5) -- powerLevel6(6) -- powerLevel7(7) -- powerLevel8(8) -- powerLevel9(9) -- powerLevel10(10) -- powerLevel11(11) -- powerShutNWakeUp(12) -- powerUsage(13) -- powerImportance(14) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the nanny vector of the current Cisco EnergyWise entity. powerWakeUp(0): Feature to wake up a Cisco EnergyWise entity. powerLevel1(1): Feature to set to power level 1(shut). powerLevel2(2): Feature to set to power level 2(hibernate). powerLevel3(3): Feature to set to power level 3(sleep). powerLevel4(4): Feature to set to power level 4(standby) powerLevel5(5): Feature to set to power level 5(ready). powerLevel6(6): Feature to set to power level 6(low). powerLevel7(7): Feature to set to power level 7(frugal). powerLevel8(8): Feature to set to power level 8(medium). powerLevel9(9): Feature to set to power level 9(reduced). powerLevel10(10): Feature to set to power level 10(high). powerLevel11(11): Feature to set to power level 11(full). powerShutNWakeUp: Feature to shutdown and wake up a Cisco EnergyWise entity. powerUsage: Feature to manage Cisco EnergyWise usage of a Cisco EnergyWise entity. powerImportance: Feature to manage Cisco EnergyWise importance of a Cisco EnergyWise entity." ::= { cewEntEntry 1 } cewEntNeighborIndex OBJECT-TYPE SYNTAX Gauge(1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates an arbitrary unsigned integer-value that uniquely identifies the Cisco EnergyWise neighbor, for which the current Cisco EnergyWise entity serves as a nanny." ::= { cewEntEntry 2 } cewEntKeyword OBJECT-TYPE SYNTAX EnergywiseKeywordList -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the EnergywiseKeywordList with which this entity is tagged. This object specifies the null string if no keyword has been configured. If write access is implemented for an instance of cewEntKeyword, and a value is written into the instance, the agent must retain the supplied value in the cewEntKeyword instance associated with the same physical entity for as long as that entity remains instantiated. This includes instantiations across all re-initializations/reboots of the network management system, including those which result in a change of the physical entity's entPhysicalIndex value." ::= { cewEntEntry 3 } cewEntName OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies an administratively assigned human readable name to the Cisco EnergyWise entity. For example, we can have a switch deployed to lobby with cewEntName as 'LL'. This object specifies a null string if no name is configured. If write access is implemented for an instance of cewEntName, and a value is written into the instance, the agent must retain the supplied value in the cewEntname instance associated with the same physical entity for as long as that entity remains instantiated. This includes instantiations across all re-initializations/reboots of the network management system, including those which result in a change of the physical entity's entPhysicalIndex value." ::= { cewEntEntry 4 } cewEntRoleDescription OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies an administratively assigned name to indicate the purpose a Cisco EnergyWise entity serves in the network. For example, we can have switches deployed to a lobby with cewEntName as 'LL', cewEntRoleDescription as 'LobbySwitch'. This object specifies a null string if no role description is configured. If write access is implemented for an instance of cewEntRoleDescription, and a value is written into the instance, the agent must retain the supplied value in the cewEntRoleDescription instance associated with the same physical entity for as long as that entity remains instantiated. This includes instantiations across all re- initializations/reboots of the network management system, including those which result in a change of the physical entity's entPhysicalIndex value." ::= { cewEntEntry 5 } cewEntFullName OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the full name of a Cisco EnergyWise entity. This name is the combination of the cewDomainName, cewEntRoleDescription, cewEntName. For example, we can have a switch deployed to lobby with cewEntFullName as 'com.cisco.bldg19.LobbySwitch.LL' where, cewDomainName - gcom.cisco.bldg19 cewEntRole - LobbySwitch cewEntName - LL" ::= { cewEntEntry 6 } cewEntEnergyUnits OBJECT-TYPE SYNTAX EnergywisePowerUnits -- Rsyntax INTEGER(-24..24) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the units of power for the Cisco EnergyWise entity. The value of this column applies to the following objects: cewEntEnergyUsage cewEntEnergyUsageProvisioned." ::= { cewEntEntry 7 } cewEntEnergyUsage OBJECT-TYPE SYNTAX Gauge(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the current usage for the Cisco EnergyWise entity. This should be less than or equal to the power that can be consumed at that specified level." ::= { cewEntEntry 8 } cewEntEnergyUsageCaliber OBJECT-TYPE SYNTAX INTEGER { max(1), presumed(2), unknown(3), actual(4), trusted(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the type of the usage data reported by cewEntityEnergyUsage. max: This indicates that the actual power drawn cannot be determined. A presumed value that is the maximum the Cisco EnergyWise entity could draw is provided. presumed: This indicates that the actual power drawn cannot be determined but can be presumed from the model. A dell box X draws 200W, Dell Model y draws 210W. actual: This indicates that the usage data reported is not presumed or max but the real power drawn. A PoE phone drawing X amount of power can be determined by reading from the port. A PoE phone can report the actual usage as X W. unknown: This indicates that the usage reported is unknown. In some cases, entities report aggregate power like what a lighting controller or aggregate controller does. In such cases it is not known whether the usage reported is actual or presumed. trusted: This indicates that the usage data reported was reported from another source." ::= { cewEntEntry 9 } cewEntEnergyLevel OBJECT-TYPE SYNTAX EnergywiseLevel -- Rsyntax INTEGER { -- shut(1), -- hibernate(2), -- sleep(3), -- standby(4), -- ready(5), -- low(6), -- frugal(7), -- medium(8), -- reduced(9), -- high(10), -- full(11) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the current power level for the Cisco EnergyWise entity." ::= { cewEntEntry 10 } cewEntEnergyUsageProvisioned OBJECT-TYPE SYNTAX Gauge(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the maximum power a Cisco EnergyWise entity can draw at current level." ::= { cewEntEntry 11 } cewEntImportanceInt OBJECT-TYPE SYNTAX Gauge(1..100) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies Cisco EnergyWise importance for the Cisco EnergyWise entity." DEFVAL { 1 } ::= { cewEntEntry 12 } cewEntImportanceExt OBJECT-TYPE SYNTAX Gauge(1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the sum of its own importance and intrinsic importance of all the entities dependent on it." ::= { cewEntEntry 13 } cewEntImportanceRelative OBJECT-TYPE SYNTAX Gauge(1..100) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the relative importance of a Cisco EnergyWise entity with respect to the maximum importance value in the domain. It is derived using the formula: (cewEntImportanceExt / cewEntMaxImportance) * 100." ::= { cewEntEntry 14 } cewEntImportanceParentId OBJECT-TYPE SYNTAX EnergywiseId -- Rsyntax OCTET STRING(SIZE(0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates a Cisco EnergyWise entity, which identifies itself as important for the current entity's functionality in the network. For example, assume a network consisting of switches, IP phones and a call manager (device which supports call related operations in a phone). Though an IP phone derives its power from the switch, it will not work if the call-manager is not operational. It clearly demonstrates the importance of the call-manager in the network. Hence it is the parent of the IP phones in terms of importance. Given a parent and child relationship this can be read as, child (IP phone) needs parent (call manager). Importance calculations enable the management stations to identify the Cisco EnergyWise entities that support other Cisco EnergyWise entities and weigh them as more important to the network as a whole." ::= { cewEntEntry 15 } cewEntParentId OBJECT-TYPE SYNTAX EnergywiseId -- Rsyntax OCTET STRING(SIZE(0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the Cisco EnergyWise parent of this entity. If a Cisco EnergyWise entity is a Cisco EnergyWise parent, then the value of this column is the null string." ::= { cewEntEntry 16 } cewEntAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A control object to indicate the administratively desired state for the Cisco EnergyWise entity. up: enables Cisco EnergyWise protocol on the entity. down: disables Cisco EnergyWise protocol on the entity." ::= { cewEntEntry 17 } cewEntOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), error(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the operational status for the Cisco EnergyWise entity. If the cewEntAdminStatus is down(2), then cewEntOperStatus should be down(2). If cewEntAdminStatus is changed to up(1), then cewEntOperStatus should change to up(1), unless some error has occurred, then it should be in error(3) state." ::= { cewEntEntry 18 } cewEntConfiguredLevel OBJECT-TYPE SYNTAX EnergywiseLevel -- Rsyntax INTEGER { -- shut(1), -- hibernate(2), -- sleep(3), -- standby(4), -- ready(5), -- low(6), -- frugal(7), -- medium(8), -- reduced(9), -- high(10), -- full(11) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the level set by the network administrator. The value of this object could change if the recurrence event is fired. When a network administrator sets the level of this object the value of cewEntEnergyLevel will change to that value if the configured level is successfully accepted by the system." ::= { cewEntEntry 19 } cewEntEnergyUsageCategory OBJECT-TYPE SYNTAX INTEGER { consumer(1), producer(2), meter(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the energy usage type of this Cisco Energywise Entity. consumer: This indicates that the Cisco Energywise Entity consumes energy. producer: This indicates that the Cisco Energywise Entity generates energy. meter: This indicates that the Cisco Energywise Entity is a meter which reads the energy consumed or produced." ::= { cewEntEntry 20 } cewEntEnergyUsageDirection OBJECT-TYPE SYNTAX INTEGER { --?? negative enum value may cause problems -- out(-1), in(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the direction of the energy usage by this Cisco EnergyWise Entity, with respect to the power grid. out: This indicates that the power is being consumed or drawn out of the power grid by the Cisco EnergyWise Entity. in: This indicates that the power is being produced and supplied into the power grid by the Cisco EnergyWise Entity." ::= { cewEntEntry 21 } cewEntAllowSet OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the value of the flag used to determine if the Cisco Energywise Query Set is set to true/false. If the flag is set to true, the cli, energywise allow query set is activated for this Cisco Energywise Entity. When its set to false, the user will be prevented from setting the parameters from the query. For more information on Cisco Energywise Queries, refer to the description above." ::= { cewEntEntry 22 } cewEntActivityCheck OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the value of the flag used to determine if activity check is allowed or not on this Cisco Energywise Entity. If the flag is set to true, Energywise allows activity check to be done on this Cisco Energywise Entity.Activity check is done to determine if an IP Phone entity connected to the switch is in use or not before the port can be turned OFF or ON." ::= { cewEntEntry 23 } cewLevelTable OBJECT-TYPE SYNTAX SEQUENCE OF CewLevelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table lists the power usage at each level for each Cisco EnergyWise entity. This table has an expansion dependent relationship on the cewEntTable, containing rows describing each level for the corresponding Cisco EnergyWise entity." ::= { ciscoEnergywiseMIBObjects 7 } cewLevelEntry OBJECT-TYPE SYNTAX CewLevelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A cewLevelEntry extends a corresponding cewEntEntry. This entry displays max usage and delta values at each level. For example, Given the values of a Cisco EnergyWise entity as below: Level Usage UsageProvisioned 2 11 15 UsageVector DeltaVector (0,10,15,25,35,...100) (11, 1, -4, -14, -24,...,-89)" INDEX { entPhysicalIndex, cewLevelIndex } ::= { cewLevelTable 1 } CewLevelEntry ::= SEQUENCE { cewLevelIndex EnergywiseLevel, cewLevelMaxUsage Gauge, cewLevelDeltaUsage INTEGER, cewLevelUnits EnergywisePowerUnits } cewLevelIndex OBJECT-TYPE SYNTAX EnergywiseLevel -- Rsyntax INTEGER { -- shut(1), -- hibernate(2), -- sleep(3), -- standby(4), -- ready(5), -- low(6), -- frugal(7), -- medium(8), -- reduced(9), -- high(10), -- full(11) -- } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object indicates the level for which this entry describes the power usage." ::= { cewLevelEntry 1 } cewLevelMaxUsage OBJECT-TYPE SYNTAX Gauge(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the maximum power usage for the Cisco EnergyWise entity at the particular level." ::= { cewLevelEntry 2 } cewLevelDeltaUsage OBJECT-TYPE SYNTAX INTEGER(-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the delta; that is the difference between the current cewEntityEnergyUsage and the cewLevelMaxUsage value of a Cisco EnergyWise entity at a level." ::= { cewLevelEntry 3 } cewLevelUnits OBJECT-TYPE SYNTAX EnergywisePowerUnits -- Rsyntax INTEGER(-24..24) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the Cisco EnergyWise power units for cewLevelMaxUsage and cewLevelDeltaUsage values." ::= { cewLevelEntry 4 } cewProxyTable OBJECT-TYPE SYNTAX SEQUENCE OF CewProxyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table lists Cisco EnergyWise proxies. This table has an expansion dependent relationship on the cewEntTable, containing zero or more rows for each row in the cewEntTable." ::= { ciscoEnergywiseMIBObjects 8 } cewProxyEntry OBJECT-TYPE SYNTAX CewProxyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry describes the attributes, required to be configured on a Cisco EnergyWise entity to reach the Cisco EnergyWise proxy. An entry is created/deleted in cewProxyTable, whenever an Cisco EnergyWise entity is configured/unconfigured with above attributes." INDEX { entPhysicalIndex, cewProxyId } ::= { cewProxyTable 1 } CewProxyEntry ::= SEQUENCE { cewProxyId Gauge, cewProxyAddressType InetAddressType, cewProxyAddress InetAddress, cewProxyPort InetPortNumber, cewProxyClass SnmpAdminString, cewProxyStorage StorageType, cewProxyStatus RowStatus } cewProxyId OBJECT-TYPE SYNTAX Gauge(1..4294967295) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object indicates an arbitrary unsigned integer-value that uniquely identifies the proxy." ::= { cewProxyEntry 1 } cewProxyAddressType OBJECT-TYPE SYNTAX InetAddressType -- Rsyntax INTEGER { -- ?? enum value of zero may cause problems -- unknown(0), -- ipv4(1), -- ipv6(2), -- ipv4z(3), -- ipv6z(4), -- dns(16) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the address type used for cewProxyAddress. Cisco EnergyWise proxy entries are only valid for the address type of ipv4(1) and ipv6(2)." ::= { cewProxyEntry 2 } cewProxyAddress OBJECT-TYPE SYNTAX InetAddress -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the IP address of the proxy." ::= { cewProxyEntry 3 } cewProxyPort OBJECT-TYPE SYNTAX InetPortNumber -- Rsyntax Gauge(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the port used by the proxy." ::= { cewProxyEntry 4 } cewProxyClass OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies a string which a network administrator can use to classify Cisco EnergyWise proxies to particular proxy type. For example, all the building controllers (Cisco EnergyWise proxies which understand BACNET proprietary protocol) will be tagged with 'BACNET' string." ::= { cewProxyEntry 5 } cewProxyStorage OBJECT-TYPE SYNTAX StorageType -- Rsyntax INTEGER { -- other(1), -- volatile(2), -- nonVolatile(3), -- permanent(4), -- readOnly(5) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the memory realization of a Cisco EnergyWise proxy." DEFVAL { volatile } ::= { cewProxyEntry 6 } cewProxyStatus OBJECT-TYPE SYNTAX RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the status of this proxy. Once the entry status has been set to active(1), the entry cannot be modified. The only operation possible after this is to delete the entry." ::= { cewProxyEntry 7 } cewNeighborTable OBJECT-TYPE SYNTAX SEQUENCE OF CewNeighborEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table lists Cisco EnergyWise neighbors. Cisco EnergyWise entity reports its connection to the network via a discovery protocol. When a new Cisco EnergyWise neighbor is discovered, this table is updated with the new entry. When the Cisco EnergyWise neighbor looses its connection, corresponding neighbor entry is deleted from the table." ::= { ciscoEnergywiseMIBObjects 9 } cewNeighborEntry OBJECT-TYPE SYNTAX CewNeighborEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the cewNeighborTable. An entry describes the attributes of the Cisco EnergyWise neighbor, either discovered through a discovery protocol or has been added as a static neighbor by the management station." INDEX { cewNeighborIndex } ::= { cewNeighborTable 1 } CewNeighborEntry ::= SEQUENCE { cewNeighborIndex Gauge, cewNeighborId EnergywiseId, cewNeighborType INTEGER, cewNeighborHeartBeat TimeStamp, cewNeighborStorage StorageType, cewNeighborStatus RowStatus, cewNeighborDeviceType SnmpAdminString, cewNeighborKeyword EnergywiseKeywordList, cewNeighborConfiguredKeyword EnergywiseKeywordList, cewNeighborName SnmpAdminString, cewNeighborConfiguredName SnmpAdminString, cewNeighborRoleDescription SnmpAdminString, cewNeighborConfiguredRoleDesc SnmpAdminString, cewNeighborEnergyLevel EnergywiseLevel, cewNeighborConfiguredLevel EnergywiseLevel, cewNeighborImportance Gauge, cewNeighborConfiguredImportance Gauge, cewNeighborEnergyUnits EnergywisePowerUnits, cewNeighborEnergyUsage Gauge, cewNeighborEnergyUsageCategory INTEGER, cewNeighborEnergyUsageDirection INTEGER, cewNeighborMacAddress MacAddress, cewNeighborPhysicalEntityId EntPhysicalIndexOrZero, cewNeighborParentPortIndex EntPhysicalIndexOrZero } cewNeighborIndex OBJECT-TYPE SYNTAX Gauge(1..4294967295) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object indicates an arbitrary unsigned integer-value that uniquely identifies the Cisco EnergyWise neighbor." ::= { cewNeighborEntry 1 } cewNeighborId OBJECT-TYPE SYNTAX EnergywiseId -- Rsyntax OCTET STRING(SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the Cisco EnergyWise identifier of the neighbor." ::= { cewNeighborEntry 2 } cewNeighborType OBJECT-TYPE SYNTAX INTEGER { static(1), dynamic(2), child(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the type of a Cisco EnergyWise neighbor static : specifies a neighbor which is added statically. dynamic : specifies a neighbor added dynamically, by a discovery protocol. child : specifies a neighbor which needs a parent to nanny." ::= { cewNeighborEntry 3 } cewNeighborHeartBeat OBJECT-TYPE SYNTAX TimeStamp -- Rsyntax TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the value of sysUpTime the last time a heartbeat was received from the neighbor Cisco EnergyWise entity." ::= { cewNeighborEntry 4 } cewNeighborStorage OBJECT-TYPE SYNTAX StorageType -- Rsyntax INTEGER { -- other(1), -- volatile(2), -- nonVolatile(3), -- permanent(4), -- readOnly(5) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the memory realization of a Cisco EnergyWise neighbor." DEFVAL { volatile } ::= { cewNeighborEntry 5 } cewNeighborStatus OBJECT-TYPE SYNTAX RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the status of this neighbor. Once the entry status has been set to active(1), the entry cannot be modified. The only operation possible after this is to delete the entry." ::= { cewNeighborEntry 6 } cewNeighborDeviceType OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the device type of the Cisco EnergyWise neighbor. This object should be same as the cewDeviceType of the neighbor." ::= { cewNeighborEntry 7 } cewNeighborKeyword OBJECT-TYPE SYNTAX EnergywiseKeywordList -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the EnergywiseKeywordList with which this Cisco Energywise endpoint neighbor entity is tagged. If cewNeighborConfiguredKeyword is successfully changed, the new value will be copied over to cewNeighborKeyword to make both the objects have the same value. This object specifies the null string if no keyword has been configured." ::= { cewNeighborEntry 8 } cewNeighborConfiguredKeyword OBJECT-TYPE SYNTAX EnergywiseKeywordList -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the keyword configured by the network administrator on the adjacent Cisco energywise neighbor/child entity. If the neighbor is of type child and a keyword is configured, the switch will attempt to set the endpoint neighbor/child entity with this value. If the set operation is successful, cewNeighborKeyword will be set with the configured keyword. This object specifies the EnergywiseKeywordList with which current Cisco Energywise neighbor/endpoint entity is tagged. This object specifies the null string if no keyword has been configured. If write access is implemented for an instance of cewNeighborConfiguredKeyword, and a value is written into the instance,the agent must retain the supplied value in the cewNeighborConfiguredKeyword instance associated with the same physical entity for as long as that entity remains instantiated. This includes instantiations across all re-initializations/reboots of the network management system, including those which result in a change of the physical entity's entPhysicalIndex value." ::= { cewNeighborEntry 9 } cewNeighborName OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies an administratively assigned human readable name to the Cisco Energywise endpoint neighbor/child. If cewNeighborConfiguredName is successfully changed, the new value will be copied over to cewNeighborName to make both the objects have the same value. This object specifies a null string if no name is configured." ::= { cewNeighborEntry 10 } cewNeighborConfiguredName OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the name configured on the adjacent Cisco Energywise neighbor/child entity. If the neighbor is of type child and a name is configured, the switch will attempt to set the endpoint neighbor/child entity with this value. If successful,cewNeighborName will be set with the configured name. This object specifies a null string if no name is configured. If write access is implemented for an instance of cewNeighborConfiguredName, and a value is written into the instance, the agent must retain the supplied value in the cewNeighborConfiguredName instance associated with the same physical entity for as long as that entity remains instantiated. This includes instantiations across all re-initializations/reboots of the network management system, including those which result in a change of the physical entity's entPhysicalIndex value." ::= { cewNeighborEntry 11 } cewNeighborRoleDescription OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies an administratively assigned name to indicate the purpose the Cisco Energywise endpoint neighbor/child serves in the network.If cewNeighborConfiguredRoleDesc is successfully changed, the new value will be copied over to cewNeighborRoleDescription to make both the objects have the same value. This object specifies a null string if no role description is configured." ::= { cewNeighborEntry 12 } cewNeighborConfiguredRoleDesc OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the role configured on the adjacent Cisco Energywise neighbor/child entity.If the neighbor is of type child and a role is configured, the switch will attempt to set the endpoint neighbor/child entity with this value. If successful, cewNeighborRoleDesc will be set with the configured role. This object specifies an administratively assigned name to indicate the purpose a Cisco EnergyWise entity serves in the network. This object specifies a null string if no role description is configured. If write access is implemented for an instance of cewNeighborConfiguredRoleDesc, and a value is written into the instance, the agent must retain the supplied value in the cewNeighborConfiguredRoleDesc instance associated with the same physical entity for as long as that entity remains instantiated. This includes instantiations across all re-initializations/reboots of the network management system, including those which result in a change of the physical entity's entPhysicalIndex value." ::= { cewNeighborEntry 13 } cewNeighborEnergyLevel OBJECT-TYPE SYNTAX EnergywiseLevel -- Rsyntax INTEGER { -- shut(1), -- hibernate(2), -- sleep(3), -- standby(4), -- ready(5), -- low(6), -- frugal(7), -- medium(8), -- reduced(9), -- high(10), -- full(11) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the current power level for the Cisco EnergyWise neighbor/child entity." ::= { cewNeighborEntry 14 } cewNeighborConfiguredLevel OBJECT-TYPE SYNTAX EnergywiseLevel -- Rsyntax INTEGER { -- shut(1), -- hibernate(2), -- sleep(3), -- standby(4), -- ready(5), -- low(6), -- frugal(7), -- medium(8), -- reduced(9), -- high(10), -- full(11) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the level configured on the adjacent Cisco Energywise neighbor/child entity. If the neighbor is of type child and a level is configured, the switch will attempt to set the endpoint neighbor/child entity with this value. If successful, cewNeighborEnergyLevel will be set with the configured level." ::= { cewNeighborEntry 15 } cewNeighborImportance OBJECT-TYPE SYNTAX Gauge(1..100) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies Cisco EnergyWise importance for the Cisco EnergyWise neighbor/child entity." DEFVAL { 1 } ::= { cewNeighborEntry 16 } cewNeighborConfiguredImportance OBJECT-TYPE SYNTAX Gauge(1..100) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the importance configured on the adjacent Cisco Energywise neighbor/child entity. If the neighbor is of type child and the importance is configured, the switch will attempt to set the endpoint neighbor/child entity with this value. If successful, cewNeighborImportance will be set with the configured importance." DEFVAL { 1 } ::= { cewNeighborEntry 17 } cewNeighborEnergyUnits OBJECT-TYPE SYNTAX EnergywisePowerUnits -- Rsyntax INTEGER(-24..24) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the units of power for the Cisco Energywise neighbor/child entity. The value of this column applies to the following objects: cewNeighborEnergyUsage" ::= { cewNeighborEntry 18 } cewNeighborEnergyUsage OBJECT-TYPE SYNTAX Gauge(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the current usage for the Cisco EnergyWise neighbor/child entity. This should be less than or equal to the power that can be consumed at that specified level." ::= { cewNeighborEntry 19 } cewNeighborEnergyUsageCategory OBJECT-TYPE SYNTAX INTEGER { consumer(1), producer(2), meter(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the energy usage type of the Cisco Energywise neighbor/child entity. consumer: This indicates that the neighbor consumes energy. producer: This indicates that the neighbor generates energy. meter: This indicates that the neighbor is a meter which reads the energy consumed or produced." ::= { cewNeighborEntry 20 } cewNeighborEnergyUsageDirection OBJECT-TYPE SYNTAX INTEGER { --?? negative enum value may cause problems -- out(-1), in(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the direction of the energy usage with respect to the power grid for this Cisco Energywise neighbor entity. Example: A solar panel is a consumer, drawing power during some part of the day, taking in power from the grid. It can also generate power out to the grid at other times. out: This indicates that the power is being consumed or drawn out by the Cisco EnergyWise neighbor entity. in: This indicates that the power is being produced and supplied back into the power grid by the Cisco EnergyWise neighbor entity." ::= { cewNeighborEntry 21 } cewNeighborMacAddress OBJECT-TYPE SYNTAX MacAddress -- Rsyntax OCTET STRING(SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the MAC Address of the Cisco EnergyWise endpoint that is connected to the Cisco EnergyWise Entity." ::= { cewNeighborEntry 22 } cewNeighborPhysicalEntityId OBJECT-TYPE SYNTAX EntPhysicalIndexOrZero -- Rsyntax INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the entity physical index of the Cisco Energywise Neighbor. If the neighbor is not a cisco device that supports the cisco entity MIB, this value will be zero." ::= { cewNeighborEntry 23 } cewNeighborParentPortIndex OBJECT-TYPE SYNTAX EntPhysicalIndexOrZero -- Rsyntax INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the entPhysicalIndex of the interface on the switch to which the Cisco EnergyWise endpoint is connected." ::= { cewNeighborEntry 24 } cewEventTable OBJECT-TYPE SYNTAX SEQUENCE OF CewEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table lists Cisco EnergyWise events. This table has an expansion dependent relationship on the cewEntTable, containing zero or more rows for each row in the cewEntTable." ::= { ciscoEnergywiseMIBObjects 10 } cewEventEntry OBJECT-TYPE SYNTAX CewEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry describes the attributes, required to be configured on a Cisco EnergyWise entity, to trigger the Cisco EnergyWise event. An entry is created/deleted in cewEventTable, whenever an Cisco EnergyWise entity is configured/unconfigured with above attributes." INDEX { entPhysicalIndex, cewEventIndex } ::= { cewEventTable 1 } CewEventEntry ::= SEQUENCE { cewEventIndex Gauge, cewEventLevel EnergywiseLevel, cewEventRecurrence TruthValue, cewEventTime SnmpAdminString, cewEventStorage StorageType, cewEventStatus RowStatus, cewEventImportance Gauge } cewEventIndex OBJECT-TYPE SYNTAX Gauge(1..4294967295) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies an arbitrary unsigned integer-value that uniquely identifies the Cisco EnergyWise event." ::= { cewEventEntry 1 } cewEventLevel OBJECT-TYPE SYNTAX EnergywiseLevel -- Rsyntax INTEGER { -- shut(1), -- hibernate(2), -- sleep(3), -- standby(4), -- ready(5), -- low(6), -- frugal(7), -- medium(8), -- reduced(9), -- high(10), -- full(11) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the level at which a Cisco EnergyWise entity is set for an event." ::= { cewEventEntry 2 } cewEventRecurrence OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies whether an event is a recurring event. true: If this policy is a recurring event. false: If this policy is not a recurring event." DEFVAL { true } ::= { cewEventEntry 3 } cewEventTime OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies a string-value describing the details regarding the time at which the event should get triggered. For example, 00:30 Hrs on Jan, June & Dec, every weekday (Mon-Fri) 30 0 * 1,6,12 1-5 * * * * * command to be executed - - - - - | | | | | | | | | +----- day of week (0 - 6) Sunday=0 | | | +------- month (1 - 12) | | +--------- day of month (1 - 31) | +----------- hour (0 - 23) +------------- min (0 - 59) Other management interfaces (e.g., local console) will configure time in the above manner. cewEventTime can also have wild cards as shown in the above example." ::= { cewEventEntry 4 } cewEventStorage OBJECT-TYPE SYNTAX StorageType -- Rsyntax INTEGER { -- other(1), -- volatile(2), -- nonVolatile(3), -- permanent(4), -- readOnly(5) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the memory realization of a Cisco EnergyWise event." DEFVAL { volatile } ::= { cewEventEntry 5 } cewEventStatus OBJECT-TYPE SYNTAX RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the status of this event. Once the entry status has been set to active(1), the entry cannot be modified. The only operation possible after this is to delete the entry." ::= { cewEventEntry 6 } cewEventImportance OBJECT-TYPE SYNTAX Gauge(1..100) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the importance at which a Cisco EnergyWise entity is set for an event." ::= { cewEventEntry 7 } cewLevelChangeNotifEnable OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies whether to enable/disable the cewLevelChange notification." ::= { ciscoEnergywiseMIBObjects 11 } cewNeighborAddedNotifEnable OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies whether to enable/disable the cewNeighborAdded notification." ::= { ciscoEnergywiseMIBObjects 12 } cewNeighborDeletedNotifEnable OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies whether to enable/disable the cewNeighborDeleted notification." ::= { ciscoEnergywiseMIBObjects 13 } cewEventOccuredNotifEnable OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies whether to enable/disable the cewEventOccured notification." ::= { ciscoEnergywiseMIBObjects 14 } cewEventOccuredErrorCode OBJECT-TYPE SYNTAX INTEGER { noerror(1), wrongtype(2), outofrange(3), swfault(4), hwfault(5) } ACCESS not-accessible STATUS mandatory DESCRIPTION "An enumerated integer value that represents different error codes when an event occurs. noerror(1) : Event occurred without any error. wrongtype(2) : Event was set with wrong value. outofrange(3) : Set on event called with out of range values. swfault(4) : Event encountered a software fault. hwfault(5) : Event encountered a hardware fault." ::= { ciscoEnergywiseMIBObjects 15 } cewManagementSecret OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the shared secret used to allow Management station to authenticate itself to connect to current Cisco EnergyWise entity via the management port over different type of protocols like HTTP, SSH. This object should be set by the user or network administrator with very high access control using only SNMPv3 protocol with authentication and privilege options." ::= { ciscoEnergywiseMIBObjects 16 } cewEndPointSecret OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the shared secret used to allow endpoints to authenticate messages that are send between current Cisco EnergyWise entity and discovered endpoints. An endpoint is a device having the capability to receive and respond Cisco EnergyWise communication messages. For example, A Desktop PC or a Laptop connected to port of a switch is an endpoint. This object should be set by the user or network administrator with very high access control using only SNMPv3 protocol with authentication and privilege options." ::= { ciscoEnergywiseMIBObjects 17 } cewDomainSecret OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the shared secret used by all the Cisco EnergyWise entities to determine their membership with a domain specified by cewDomainName. All the communications between the Cisco EnergyWise entities will be authorized based this object to keep the communication secure. This object should be set by the user or network administrator with very high access control using only SNMPv3 protocol with authentication and privilege options." ::= { ciscoEnergywiseMIBObjects 18 } cewProtocol OBJECT-TYPE SYNTAX INTEGER { udp(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the protocol used for communication between Cisco EnergyWise entities." ::= { ciscoEnergywiseMIBObjects 19 } cewAddressType OBJECT-TYPE SYNTAX InetAddressType -- Rsyntax INTEGER { -- ?? enum value of zero may cause problems -- unknown(0), -- ipv4(1), -- ipv6(2), -- ipv4z(3), -- ipv6z(4), -- dns(16) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the address type used for cewAddress. Cisco EnergyWise is only valid for the address type of ipv4(1) and ipv6(2)." ::= { ciscoEnergywiseMIBObjects 20 } cewAddress OBJECT-TYPE SYNTAX InetAddress -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the IP address of the interface that sends EnergyWise communication messages." ::= { ciscoEnergywiseMIBObjects 21 } cewPort OBJECT-TYPE SYNTAX InetPortNumber -- Rsyntax Gauge(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the port number used for sending and receiving the Cisco EnergyWise communication messages." ::= { ciscoEnergywiseMIBObjects 22 } cewEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A control object to activate/de-activate Cisco EnergyWise protocol at global level on a Cisco EnergyWise entity (e.g. Switch). This object should be set to enable state only when the following objects are set: cewDomainName cewDomainSecret cewProtocol cewPort cewAddressType cewAddress enable: enables Cisco EnergyWise protocol at a global level on a Cisco EnergyWise entity. disable: disables Cisco EnergyWise protocol at a global level on a Cisco EnergyWise entity." ::= { ciscoEnergywiseMIBObjects 23 } cewVersion OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the current version of the Cisco EnergyWise software running on a Cisco Energywise Entity." ::= { ciscoEnergywiseMIBObjects 24 } cewDeviceTotalUsage OBJECT-TYPE SYNTAX Gauge(0..2147483647) -- Units -- watts ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the sum of the cewEntEnergyUsage of the current Cisco EnergyWise entity and the cewEntEnergyUsage of all its children." ::= { ciscoEnergywiseMIBObjects 25 } cewDeviceTotalUsageUnits OBJECT-TYPE SYNTAX EnergywisePowerUnits -- Rsyntax INTEGER(-24..24) -- Units -- watts ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the units of power for cewDeviceTotalUsage." ::= { ciscoEnergywiseMIBObjects 26 } cewDeviceType OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the type of the Cisco EnergyWise device." ::= { ciscoEnergywiseMIBObjects 27 } cewAllowSet OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "When this object is set to true, the cli, energywise allow query set is activated for the Cisco Energywise Entity. When its set to false, the user will be prevented from setting the parameters from the query." ::= { ciscoEnergywiseMIBObjects 28 } cewNeighborLevelTable OBJECT-TYPE SYNTAX SEQUENCE OF CewNeighborLevelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table lists the power usage at each level for each Cisco EnergyWise neighbor entity. This table has an expansion dependent relationship on the cewNeighborTable, containing rows describing each level for the corresponding Cisco EnergyWise neighbor entity." ::= { ciscoEnergywiseMIBObjects 29 } cewNeighborLevelEntry OBJECT-TYPE SYNTAX CewNeighborLevelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A cewNeighborLevelEntry extends a corresponding cewNeighborEntry. This entry displays max usage and delta values at each level. For example, Given the values of a Cisco EnergyWise Neighbor entity as below: Level Usage UsageProvisioned 2 11 15 UsageVector DeltaVector (0,10,15,25,35,...100) (11, 1, -4, -14, -24,...,-89)" INDEX { cewNeighborIndex, cewNeighborLevelIndex } ::= { cewNeighborLevelTable 1 } CewNeighborLevelEntry ::= SEQUENCE { cewNeighborLevelIndex EnergywiseLevel, cewNeighborLevelMaxUsage Gauge, cewNeighborLevelDeltaUsage INTEGER, cewNeighborLevelUnits EnergywisePowerUnits } cewNeighborLevelIndex OBJECT-TYPE SYNTAX EnergywiseLevel -- Rsyntax INTEGER { -- shut(1), -- hibernate(2), -- sleep(3), -- standby(4), -- ready(5), -- low(6), -- frugal(7), -- medium(8), -- reduced(9), -- high(10), -- full(11) -- } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object indicates the level for which this neighbor describes the power usage." ::= { cewNeighborLevelEntry 1 } cewNeighborLevelMaxUsage OBJECT-TYPE SYNTAX Gauge(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the maximum power usage for the Cisco EnergyWise neighbor at the particular level." ::= { cewNeighborLevelEntry 2 } cewNeighborLevelDeltaUsage OBJECT-TYPE SYNTAX INTEGER(-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the delta; that is the difference between the current cewNeighborEnergyUsage and the cewNeighborLevelMaxUsage value of the Cisco EnergyWise neighbor at a level." ::= { cewNeighborLevelEntry 3 } cewNeighborLevelUnits OBJECT-TYPE SYNTAX EnergywisePowerUnits -- Rsyntax INTEGER(-24..24) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the Cisco EnergyWise power units for cewNeighborLevelMaxUsage cewNeighborLevelDeltaUsage" ::= { cewNeighborLevelEntry 4 } cewLevelChange TRAP-TYPE -- Reverse mappable trap ENTERPRISE ciscoEnergywiseMIB VARIABLES { cewEntEnergyLevel } -- Status -- mandatory DESCRIPTION "The SNMP entity generates the cewLevelChange when the value of cewEntityEnergyLevel has changed." ::= 1 cewNeighborAdded TRAP-TYPE -- Reverse mappable trap ENTERPRISE ciscoEnergywiseMIB VARIABLES { cewNeighborId, cewNeighborType } -- Status -- mandatory DESCRIPTION "The SNMP entity generates a ceweighborAdded when it discovers a Cisco EnergyWise entity neighbor." ::= 2 cewNeighborDeleted TRAP-TYPE -- Reverse mappable trap ENTERPRISE ciscoEnergywiseMIB VARIABLES { cewNeighborId, cewNeighborType } -- Status -- mandatory DESCRIPTION "The SNMP entity generates a cewNeighborDeleted trap when an Cisco EnergyWise entity neighbor is deleted. A neighbor can be deleted in the following ways: 1. The neighbor lost its connection with the current Cisco EnergyWise entity. 2. The management station deletes a neighbor entry. 3. Another management interfaces (e.g., local console) deletes the static neighbor." ::= 3 cewEventOccured TRAP-TYPE -- Reverse mappable trap ENTERPRISE ciscoEnergywiseMIB VARIABLES { cewEventLevel, cewEventOccuredErrorCode } -- Status -- deprecated DESCRIPTION "The SNMP entity generates cewEventOccured when an Cisco EnergyWise event occurs." ::= 4 cewEventOccuredRev1 TRAP-TYPE -- Reverse mappable trap ENTERPRISE ciscoEnergywiseMIB VARIABLES { cewEventLevel, cewEventImportance, cewEventOccuredErrorCode } -- Status -- mandatory DESCRIPTION "The SNMP entity generates cewEventOccured when an Cisco EnergyWise event occurs." ::= 5 ciscoEnergywiseEntityGroup OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 1 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains the collection of all the objects -- related to a Cisco EnergyWise entity. -- objects -- cewMaxImportance, cewMaxImportanceId, cewEntNeighborIndex, -- cewEntNannyVector, cewEntKeyword, cewEntName, -- cewEntRoleDescription, cewEntFullName, cewEntEnergyUnits, -- cewEntEnergyUsage, cewEntEnergyLevel, -- cewEntEnergyUsageProvisioned, cewEntImportanceInt, -- cewEntImportanceExt, cewEntImportanceParentId, cewEntParentId, -- cewEntImportanceRelative, cewEntAdminStatus, cewEntOperStatus, -- cewLevelMaxUsage, cewLevelDeltaUsage, cewLevelUnits, -- cewDeviceId, cewDeviceNeighborCount, cewEntEnergyUsageCaliber, -- cewDomainName ciscoEnergywiseNeighborGroup OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 2 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains the collection of all the objects -- related to a Cisco EnergyWise neighbor. -- objects -- cewNeighborId, cewNeighborType, cewNeighborHeartBeat, -- cewNeighborStatus, cewNeighborStorage ciscoEnergywiseEventGroup OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 3 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains the collection of all the objects -- related to a Cisco EnergyWise event. -- objects -- cewEventLevel, cewEventRecurrence, cewEventStatus, -- cewEventTime, cewEventStorage, cewEventOccuredErrorCode ciscoEnergywiseProxyGroup OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 4 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains the collection of all the objects -- related to a Cisco EnergyWise proxy. -- objects -- cewProxyAddressType, cewProxyAddress, cewProxyPort, -- cewProxyClass, cewProxyStorage, cewProxyStatus ciscoEnergywiseNotifEnableGroup OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 6 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains the collection of all the -- notification enable objects for a Cisco EnergyWise Entity. -- objects -- cewLevelChangeNotifEnable, cewNeighborAddedNotifEnable, -- cewNeighborDeletedNotifEnable, cewEventOccuredNotifEnable ciscoEnergywiseActivationGroup OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 7 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains the collection of all the objects -- required to activate Cisco EnergyWise on Cisco EnergyWise -- entity. -- objects -- cewDomainName, cewDomainSecret, cewProtocol, cewAddressType, -- cewAddress, cewPort, cewEnable ciscoEnergywiseEntityGroupSup1 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 8 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains the collection of all the objects -- related to a Cisco EnergyWise entity. -- objects -- cewEntConfiguredLevel, cewVersion, cewManagementSecret, -- cewEndPointSecret, cewDeviceTotalUsage, -- cewDeviceTotalUsageUnits ciscoEnergywiseEventGroupSup1 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 9 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains the collection of all the objects -- related to a Cisco EnergyWise event. -- objects -- cewEventImportance ciscoEnergywiseEntityGroupSup2 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 11 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains the collection of all the objects -- related to a Cisco EnergyWise event. -- objects -- cewDeviceType ciscoEnergywiseNeighborGroupSup1 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 12 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains the collection of all the objects -- related to a Cisco EnergyWise neighbor. -- objects -- cewNeighborDeviceType ciscoEnergywiseEntityGroupSup3 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 13 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains the collection of all the objects -- related to a Cisco EnergyWise event. -- objects -- cewEntEnergyUsageCategory, cewEntEnergyUsageDirection, -- cewEntAllowSet, cewEntActivityCheck, cewAllowSet ciscoEnergywiseNeighborGroupSup2 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 14 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains the collection of all the objects -- related to a Cisco EnergyWise neighbor. -- objects -- cewNeighborKeyword, cewNeighborConfiguredKeyword, -- cewNeighborName, cewNeighborConfiguredName, -- cewNeighborRoleDescription, cewNeighborConfiguredRoleDesc, -- cewNeighborEnergyLevel, cewNeighborConfiguredLevel, -- cewNeighborImportance, cewNeighborConfiguredImportance, -- cewNeighborEnergyUnits, cewNeighborEnergyUsage, -- cewNeighborEnergyUsageCategory, -- cewNeighborEnergyUsageDirection, cewNeighborLevelMaxUsage, -- cewNeighborLevelDeltaUsage, cewNeighborLevelUnits ciscoEnergywiseNeighborGroupSup3 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 15 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains the collection of objects related to a -- Cisco EnergyWise neighbor that are endpoints. -- objects -- cewNeighborMacAddress, cewNeighborPhysicalEntityId, -- cewNeighborParentPortIndex ciscoEnergywiseNotifGroup OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 5 } -- NOTIFICATION-GROUP -- Status -- deprecated -- Descr -- This group contains the collection of all the -- notifications for a Cisco EnergyWise Entity. -- notifications -- cewLevelChange, cewNeighborAdded, cewNeighborDeleted, -- cewEventOccured cewEnergywiseNotifGroupRev1 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBGroups 10 } -- NOTIFICATION-GROUP -- Status -- mandatory -- Descr -- This group contains the collection of all the -- notifications for a Cisco EnergyWise Entity. -- notifications -- cewLevelChange, cewNeighborAdded, cewNeighborDeleted, -- cewEventOccuredRev1 ciscoEnergywiseMIBFullCompliance OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBCompliances 1 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- When this MIB is implemented with support for -- read-create, then such an implementation can -- claim full compliance. Such devices can then -- be both monitored and configured with this MIB. -- Module -- >>current<< -- MandGroup -- ciscoEnergywiseEntityGroup -- MandGroup -- ciscoEnergywiseNeighborGroup -- MandGroup -- ciscoEnergywiseEventGroup -- MandGroup -- ciscoEnergywiseNotifGroup -- MandGroup -- ciscoEnergywiseNotifEnableGroup -- OptGroup -- ciscoEnergywiseProxyGroup -- ObjVar -- cewProxyStatus -- ObjVar -- cewNeighborStatus -- ObjVar -- cewEventStatus ciscoEnergywiseMIBReadOnlyCompliance OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBCompliances 2 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- When this MIB is implemented without support for -- read-create (i.e. in read-only mode), then such an -- implementation can claim read-only compliance. Such a -- device can then be monitored but can not be configured -- with this MIB. -- Module -- >>current<< -- MandGroup -- ciscoEnergywiseEntityGroup -- MandGroup -- ciscoEnergywiseNeighborGroup -- MandGroup -- ciscoEnergywiseEventGroup -- MandGroup -- ciscoEnergywiseNotifGroup -- MandGroup -- ciscoEnergywiseNotifEnableGroup -- OptGroup -- ciscoEnergywiseProxyGroup -- ObjVar -- cewDomainName -- ObjVar -- cewEntKeyword -- ObjVar -- cewEntRoleDescription -- ObjVar -- cewEntName -- ObjVar -- cewEntEnergyLevel -- ObjVar -- cewEntImportanceInt -- ObjVar -- cewEntAdminStatus -- ObjVar -- cewProxyStatus -- ObjVar -- cewNeighborStatus -- ObjVar -- cewEventStatus ciscoEnergywiseMIBFullComplianceRev1 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBCompliances 3 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- When this MIB is implemented with support for -- read-create, then such an implementation can -- claim full compliance. Such devices can then -- be both monitored and configured with this MIB. -- Module -- >>current<< -- MandGroup -- ciscoEnergywiseEntityGroup -- MandGroup -- ciscoEnergywiseNeighborGroup -- MandGroup -- ciscoEnergywiseEventGroup -- MandGroup -- ciscoEnergywiseNotifEnableGroup -- MandGroup -- ciscoEnergywiseActivationGroup -- MandGroup -- ciscoEnergywiseEntityGroupSup1 -- MandGroup -- ciscoEnergywiseEventGroupSup1 -- MandGroup -- cewEnergywiseNotifGroupRev1 -- OptGroup -- ciscoEnergywiseProxyGroup -- ObjVar -- cewProxyStatus -- ObjVar -- cewNeighborStatus -- ObjVar -- cewEventStatus ciscoEnergywiseMIBReadOnlyComplianceRev1 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBCompliances 4 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- When this MIB is implemented without support for -- read-create (i.e. in read-only mode), then such an -- implementation can claim read-only compliance. Such a -- device can then be monitored but can not be configured -- with this MIB. -- Module -- >>current<< -- MandGroup -- ciscoEnergywiseEntityGroup -- MandGroup -- ciscoEnergywiseNeighborGroup -- MandGroup -- ciscoEnergywiseEventGroup -- MandGroup -- ciscoEnergywiseNotifEnableGroup -- MandGroup -- ciscoEnergywiseActivationGroup -- MandGroup -- ciscoEnergywiseEntityGroupSup1 -- MandGroup -- ciscoEnergywiseEventGroupSup1 -- MandGroup -- cewEnergywiseNotifGroupRev1 -- OptGroup -- ciscoEnergywiseProxyGroup -- ObjVar -- cewDomainName -- ObjVar -- cewDomainSecret -- ObjVar -- cewProtocol -- ObjVar -- cewAddressType -- ObjVar -- cewAddress -- ObjVar -- cewPort -- ObjVar -- cewEnable -- ObjVar -- cewEntKeyword -- ObjVar -- cewEntRoleDescription -- ObjVar -- cewEntName -- ObjVar -- cewEntEnergyLevel -- ObjVar -- cewEntImportanceInt -- ObjVar -- cewEntAdminStatus -- ObjVar -- cewProxyStatus -- ObjVar -- cewNeighborStatus -- ObjVar -- cewEventStatus -- ObjVar -- cewManagementSecret -- ObjVar -- cewEndPointSecret ciscoEnergywiseMIBFullComplianceRev2 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBCompliances 5 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- When this MIB is implemented with support for -- read-create, then such an implementation can -- claim full compliance. Such devices can then -- be both monitored and configured with this MIB. -- Module -- >>current<< -- MandGroup -- ciscoEnergywiseEntityGroup -- MandGroup -- ciscoEnergywiseNeighborGroup -- MandGroup -- ciscoEnergywiseEventGroup -- MandGroup -- ciscoEnergywiseNotifEnableGroup -- MandGroup -- ciscoEnergywiseActivationGroup -- MandGroup -- ciscoEnergywiseEntityGroupSup1 -- MandGroup -- ciscoEnergywiseEventGroupSup1 -- MandGroup -- cewEnergywiseNotifGroupRev1 -- MandGroup -- ciscoEnergywiseEntityGroupSup2 -- MandGroup -- ciscoEnergywiseNeighborGroupSup1 -- OptGroup -- ciscoEnergywiseProxyGroup -- ObjVar -- cewProxyStatus -- ObjVar -- cewNeighborStatus -- ObjVar -- cewEventStatus ciscoEnergywiseMIBReadOnlyComplianceRev2 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBCompliances 6 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- When this MIB is implemented without support for -- read-create (i.e. in read-only mode), then such an -- implementation can claim read-only compliance. Such a -- device can then be monitored but can not be configured -- with this MIB. -- Module -- >>current<< -- MandGroup -- ciscoEnergywiseEntityGroup -- MandGroup -- ciscoEnergywiseNeighborGroup -- MandGroup -- ciscoEnergywiseEventGroup -- MandGroup -- ciscoEnergywiseNotifEnableGroup -- MandGroup -- ciscoEnergywiseActivationGroup -- MandGroup -- ciscoEnergywiseEntityGroupSup1 -- MandGroup -- ciscoEnergywiseEventGroupSup1 -- MandGroup -- cewEnergywiseNotifGroupRev1 -- MandGroup -- ciscoEnergywiseEntityGroupSup2 -- MandGroup -- ciscoEnergywiseNeighborGroupSup1 -- OptGroup -- ciscoEnergywiseProxyGroup -- ObjVar -- cewDomainName -- ObjVar -- cewDomainSecret -- ObjVar -- cewProtocol -- ObjVar -- cewAddressType -- ObjVar -- cewAddress -- ObjVar -- cewPort -- ObjVar -- cewEnable -- ObjVar -- cewEntKeyword -- ObjVar -- cewEntRoleDescription -- ObjVar -- cewEntName -- ObjVar -- cewEntEnergyLevel -- ObjVar -- cewEntConfiguredLevel -- ObjVar -- cewEntImportanceInt -- ObjVar -- cewEntAdminStatus -- ObjVar -- cewProxyStatus -- ObjVar -- cewNeighborStatus -- ObjVar -- cewEventStatus -- ObjVar -- cewManagementSecret -- ObjVar -- cewEndPointSecret ciscoEnergywiseMIBFullComplianceRev3 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBCompliances 7 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- When this MIB is implemented with support for -- read-create, then such an implementation can -- claim full compliance. Such devices can then -- be both monitored and configured with this MIB. -- Module -- >>current<< -- MandGroup -- ciscoEnergywiseEntityGroup -- MandGroup -- ciscoEnergywiseNeighborGroup -- MandGroup -- ciscoEnergywiseEventGroup -- MandGroup -- ciscoEnergywiseNotifEnableGroup -- MandGroup -- ciscoEnergywiseActivationGroup -- MandGroup -- ciscoEnergywiseEntityGroupSup1 -- MandGroup -- ciscoEnergywiseEventGroupSup1 -- MandGroup -- cewEnergywiseNotifGroupRev1 -- MandGroup -- ciscoEnergywiseEntityGroupSup2 -- MandGroup -- ciscoEnergywiseNeighborGroupSup1 -- MandGroup -- ciscoEnergywiseEntityGroupSup3 -- MandGroup -- ciscoEnergywiseNeighborGroupSup2 -- OptGroup -- ciscoEnergywiseProxyGroup -- ObjVar -- cewProxyStatus -- ObjVar -- cewNeighborStatus -- ObjVar -- cewEventStatus ciscoEnergywiseMIBReadOnlyComplianceRev3 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBCompliances 8 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- When this MIB is implemented without support for -- read-create (i.e. in read-only mode), then such an -- implementation can claim read-only compliance. Such a -- device can then be monitored but can not be configured -- with this MIB. -- Module -- >>current<< -- MandGroup -- ciscoEnergywiseEntityGroup -- MandGroup -- ciscoEnergywiseNeighborGroup -- MandGroup -- ciscoEnergywiseEventGroup -- MandGroup -- ciscoEnergywiseNotifEnableGroup -- MandGroup -- ciscoEnergywiseActivationGroup -- MandGroup -- ciscoEnergywiseEntityGroupSup1 -- MandGroup -- ciscoEnergywiseEventGroupSup1 -- MandGroup -- cewEnergywiseNotifGroupRev1 -- MandGroup -- ciscoEnergywiseEntityGroupSup2 -- MandGroup -- ciscoEnergywiseNeighborGroupSup1 -- MandGroup -- ciscoEnergywiseEntityGroupSup3 -- MandGroup -- ciscoEnergywiseNeighborGroupSup2 -- OptGroup -- ciscoEnergywiseProxyGroup -- ObjVar -- cewDomainName -- ObjVar -- cewDomainSecret -- ObjVar -- cewProtocol -- ObjVar -- cewAddressType -- ObjVar -- cewAddress -- ObjVar -- cewPort -- ObjVar -- cewEnable -- ObjVar -- cewEntKeyword -- ObjVar -- cewEntRoleDescription -- ObjVar -- cewEntName -- ObjVar -- cewEntEnergyLevel -- ObjVar -- cewEntConfiguredLevel -- ObjVar -- cewEntImportanceInt -- ObjVar -- cewEntAdminStatus -- ObjVar -- cewProxyStatus -- ObjVar -- cewNeighborStatus -- ObjVar -- cewEventStatus -- ObjVar -- cewManagementSecret -- ObjVar -- cewEndPointSecret ciscoEnergywiseMIBFullComplianceRev4 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBCompliances 9 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- When this MIB is implemented with support for -- read-create, then such an implementation can -- claim full compliance. Such devices can then -- be both monitored and configured with this MIB. -- Module -- >>current<< -- MandGroup -- ciscoEnergywiseEntityGroup -- MandGroup -- ciscoEnergywiseNeighborGroup -- MandGroup -- ciscoEnergywiseEventGroup -- MandGroup -- ciscoEnergywiseNotifEnableGroup -- MandGroup -- ciscoEnergywiseActivationGroup -- MandGroup -- ciscoEnergywiseEntityGroupSup1 -- MandGroup -- ciscoEnergywiseEventGroupSup1 -- MandGroup -- cewEnergywiseNotifGroupRev1 -- MandGroup -- ciscoEnergywiseEntityGroupSup2 -- MandGroup -- ciscoEnergywiseNeighborGroupSup1 -- MandGroup -- ciscoEnergywiseEntityGroupSup3 -- MandGroup -- ciscoEnergywiseNeighborGroupSup2 -- MandGroup -- ciscoEnergywiseNeighborGroupSup3 -- OptGroup -- ciscoEnergywiseProxyGroup -- ObjVar -- cewProxyStatus -- ObjVar -- cewNeighborStatus -- ObjVar -- cewEventStatus ciscoEnergywiseMIBReadOnlyComplianceRev4 OBJECT IDENTIFIER ::= { ciscoEnergywiseMIBCompliances 10 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- When this MIB is implemented without support for -- read-create (i.e. in read-only mode), then such an -- implementation can claim read-only compliance. Such a -- device can then be monitored but can not be configured -- with this MIB. -- Module -- >>current<< -- MandGroup -- ciscoEnergywiseEntityGroup -- MandGroup -- ciscoEnergywiseNeighborGroup -- MandGroup -- ciscoEnergywiseEventGroup -- MandGroup -- ciscoEnergywiseNotifEnableGroup -- MandGroup -- ciscoEnergywiseActivationGroup -- MandGroup -- ciscoEnergywiseEntityGroupSup1 -- MandGroup -- ciscoEnergywiseEventGroupSup1 -- MandGroup -- cewEnergywiseNotifGroupRev1 -- MandGroup -- ciscoEnergywiseEntityGroupSup2 -- MandGroup -- ciscoEnergywiseNeighborGroupSup1 -- MandGroup -- ciscoEnergywiseEntityGroupSup3 -- MandGroup -- ciscoEnergywiseNeighborGroupSup2 -- MandGroup -- ciscoEnergywiseNeighborGroupSup3 -- OptGroup -- ciscoEnergywiseProxyGroup -- ObjVar -- cewDomainName -- ObjVar -- cewDomainSecret -- ObjVar -- cewProtocol -- ObjVar -- cewAddressType -- ObjVar -- cewAddress -- ObjVar -- cewPort -- ObjVar -- cewEnable -- ObjVar -- cewEntKeyword -- ObjVar -- cewEntRoleDescription -- ObjVar -- cewEntName -- ObjVar -- cewEntEnergyLevel -- ObjVar -- cewEntConfiguredLevel -- ObjVar -- cewEntImportanceInt -- ObjVar -- cewEntAdminStatus -- ObjVar -- cewProxyStatus -- ObjVar -- cewNeighborStatus -- ObjVar -- cewEventStatus -- ObjVar -- cewManagementSecret -- ObjVar -- cewEndPointSecret END