-- MIB file created 15-Mar-2011 10:01:04, by -- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com CISCO-METRO-PHY-MIB DEFINITIONS ::= BEGIN -- From file: "CISCO-METRO-PHY-MIB.my" -- Compile options "4 7 F H N W 03 06 0B 0G 0N 0T" IMPORTS TruthValue FROM SNMPv2-TC-v1 ifIndex FROM IF-MIB ciscoExperiment FROM CISCO-SMI Counter, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; ciscoMetroPhyMIB OBJECT IDENTIFIER ::= { ciscoExperiment 69 } -- MODULE-IDENTITY -- LastUpdated -- 200509020000Z -- OrgName -- Cisco Systems, Inc. -- ContactInfo -- Cisco Systems -- Customer Service -- -- Postal: 170 W Tasman Drive -- San Jose, CA 95134 -- -- Tel: +1 800 553-NETS -- -- E-mail: cs-dwdm@cisco.com -- Descr -- This MIB module defines the managed objects for physical -- layer related interface configurations and objects -- for the protocol specific error counters for DWDM -- optical switches. -- -- This MIB contains three groups. -- -- The first group, cmPhyIf group, handles the physical layer -- related interface configurations. The cmPhyIfTable has objects -- for configuring protocol, rate, error monitoring, loopback -- mode and safety features like OFC (Open Fibre Control), laser -- safety control and forward laser control. -- -- The second group, cmPhyStatistics group, represents the -- counters that collect error statistics on the received -- data traffic for all protocols except SONET. -- The error statistics for SONET are covered -- in the SONET-MIB. -- -- The third group, cmPhySonetSectionTrace group, provides -- objects for section trace monitoring on SONET/SDH -- interfaces. -- RevDate -- 200509020000Z -- RevDescr -- Following objects have been added to cmPhyIfTable: -- cmPhyIfRate, -- cmPhyIfNegotiatedRate, -- cmPhyIfOverSubscription, -- cmPhyIfClientSubrate, -- cmPhyIfClientSubrateLock. -- -- Following Textual conventions have been added: -- CmRateType, -- CmNegotiatedRateType. -- RevDate -- 200411190000Z -- RevDescr -- cmPhyIfTransType object has been added to cmPhyIfTable. -- 'e1', 't1', 'e3', 't3', 'dvb', 'sdi' and 'its' enumeration -- has been added to cmPhyIfProtocol object. -- RevDate -- 200308250000Z -- RevDescr -- cmPhyIfAutoNegotiation object has been added to cmPhyIfTable. -- RevDate -- 200301080000Z -- RevDescr -- cmPhyIfTxBufferSize object has been added to cmPhyIfTable. -- RevDate -- 200205140000Z -- RevDescr -- The third revision of this MIB. -- -- The following new counters have been added - -- cmPhyRxCRC, -- cmPhyRxCRCOverflow, -- cmPhyHCRxCRC, -- cmPhyTxEncapFarEndPktErrors, -- cmPhyTxEncapFarEndPktErrOverflow, -- cmPhyHCTxEncapFarEndPktErrors -- -- The following objects have been deprecated - -- cmPhyIfLaserSafetyControl (moved to CISCO-OPTICAL-IF-EXTN-MIB), -- cmPhyIfForwardLaserControl (moved to CISCO-OPTICAL-IF-EXTN-MIB), -- cmPhyRxPower (moved to CISCO-OPTICAL-MONITOR-MIB), -- cmPhyRxHEC (moved to CISCO-CDL-MIB), -- cmPhyRxHECOverflow (moved to CISCO-CDL-MIB) and -- cmPhyHCRxHEC (moved to CISCO-CDL-MIB). -- RevDate -- 200108310000Z -- RevDescr -- The second revision of this MIB. -- RevDate -- 200104190000Z -- RevDescr -- The initial revision of this MIB. ciscoMetroPhyMIBObjects OBJECT IDENTIFIER ::= { ciscoMetroPhyMIB 1 } cmPhyIf OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBObjects 1 } cmPhyStatistics OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBObjects 2 } cmPhySonetSectionTrace OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBObjects 3 } ciscoMetroPhyMIBConformance OBJECT IDENTIFIER ::= { ciscoMetroPhyMIB 3 } ciscoMetroPhyMIBCompliances OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBConformance 1 } ciscoMetroPhyMIBGroups OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBConformance 2 } TransmissionType ::= INTEGER { unknown(1), copper(2), optical(3) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- An integer value that identifies the physical layer medium -- used across an interface. -- -- The value 'unknown' indicates the physical layer medium is not -- known. -- -- The value 'copper' indicates the physical layer medium is -- copper. -- -- The value 'optical' indicates the physical layer medium is -- optical. ProtocolType ::= INTEGER { other(1), unknown(2), gigabitEthernet(3), tenGigabitEthernet(4), fibreChannel(5), ficon(6), escon(7), sonet(8), sdh(9), sysplexIscCompatibility(10), sysplexIscPeer(11), sysplexTimerEtr(12), sysplexTimerClo(13), fastEthernet(14), fddi(15), e1(16), t1(17), e3(18), t3(19), dvb(20), sdi(21), its(22) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- An integer value that identifies the protocol used across an -- interface. -- -- The value 'e1' indicates an interface that implements the -- physical layer of E1. -- -- The value 't1' indicates an interface that implements the -- physical layer of T1. -- -- The value 'e3' indicates an interface that implements the -- physical layer of E3. -- -- The value 't3' indicates an interface that implements the -- physical layer of T3. -- -- The value 'dvb' indicates an interface that implements the -- physical layer of DVB. -- -- The value 'sdi' indicates an interface that implements the -- physical layer of SDI. -- -- The value 'its' indicates an interface that implements the -- physical layer of ITS. TriValue ::= INTEGER { true(1), false(2), notApplicable(3) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- A three codepoint value. CmRateType ::= INTEGER { unknown(1), auto(2), oneGbps(3), twoGbps(4), fourGbps(5), tenGbps(6) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- An integer value that identifies the rate of the interface. -- -- The value 'unknown' indicates the rate of the interface is -- not known. -- -- The value 'auto' indicates the rate of the interface is -- auto. The client interface will automatically negotiates -- its speed with its peer. -- -- The value 'oneGbps' indicates the rate of the interface is -- 1 Gigabits/sec. -- -- The value 'twoGbps' indicates the rate of the interface is -- 2 Gigabits/sec. -- -- The value 'fourGbps' indicates the rate of the interface is -- 4 Gigabits/sec. -- -- The value 'tenGbps' indicates the rate of the interface is -- 10 Gigabits/sec. CmNegotiatedRateType ::= INTEGER { notApplicable(1), negotiating(2), oneGbps(3), twoGbps(4), fourGbps(5), tenGbps(6) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- An integer value that identifies the current rate of the -- interface after the auto negotiation. -- -- The value 'notApplicable' indicates this object is not -- applicable for the interface. -- -- The value 'negotiating' indicates the interface is in the -- process of negotiating its speed with its peer. -- -- The value 'oneGbps' indicates the rate of the interface is -- 1 Gigabits/sec after auto negotiation. -- -- The value 'twoGbps' indicates the rate of the interface is -- 2 Gigabits/sec after auto negotiation. -- -- The value 'fourGbps' indicates the rate of the interface is -- 4 Gigabits/sec after auto negotiation. -- -- The value 'tenGbps' indicates the rate of the interface is -- 10 Gigabits/sec after auto negotiation. cmPhyIfTable OBJECT-TYPE SYNTAX SEQUENCE OF CmPhyIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table allows physical layer related interface configurations on an interface." ::= { cmPhyIf 1 } cmPhyIfEntry OBJECT-TYPE SYNTAX CmPhyIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A collection of objects for configuration on an interface." INDEX { ifIndex } ::= { cmPhyIfTable 1 } CmPhyIfEntry ::= SEQUENCE { cmPhyIfMode INTEGER, cmPhyIfProtocol ProtocolType, cmPhyIfClockRate INTEGER, cmPhyIfMonitor TruthValue, cmPhyIfLoopback INTEGER, cmPhyIfOFC TruthValue, cmPhyIfLaserSafetyControl TruthValue, cmPhyIfForwardLaserControl TruthValue, cmPhyIfTxBufferSize Gauge, cmPhyIfAutoNegotiation TriValue, cmPhyIfTransType TransmissionType, cmPhyIfRate CmRateType, cmPhyIfNegotiatedRate CmNegotiatedRateType, cmPhyIfOverSubscription TriValue, cmPhyIfClientSubrate Gauge, cmPhyIfClientSubrateLock TruthValue } cmPhyIfMode OBJECT-TYPE SYNTAX INTEGER { mode2R(1), mode3R(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the management client to configure the mode of operation for the client interface modules. When in 2R mode, there is no protocol type, clock rate or monitoring to be configured i.e. the next three objects would be read-only. When in 3R mode, monitoring can be enabled or disabled and the clock rate and protocol should be configured." ::= { cmPhyIfEntry 1 } cmPhyIfProtocol OBJECT-TYPE SYNTAX ProtocolType -- Rsyntax INTEGER { -- other(1), -- unknown(2), -- gigabitEthernet(3), -- tenGigabitEthernet(4), -- fibreChannel(5), -- ficon(6), -- escon(7), -- sonet(8), -- sdh(9), -- sysplexIscCompatibility(10), -- sysplexIscPeer(11), -- sysplexTimerEtr(12), -- sysplexTimerClo(13), -- fastEthernet(14), -- fddi(15), -- e1(16), -- t1(17), -- e3(18), -- t3(19), -- dvb(20), -- sdi(21), -- its(22) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to specify the protocol of the data carried over the client side interface. This object applies to linecards which support a variety of protocols and allow dynamic configuration of the specific protocol to be monitored on the interface. The ifType value for such interfaces remains fixed. The agent may use this object to identify the protocol to be monitored (see the cmPhyIfMonitor object), to set the clock rate for the interface (see the cmPhyIfClockRate object), or to enable or disable functionality related to the protocol, for example OFC (see the cmPhyIfOFC object). The value of this object cannot be modified when the cmPhyIfMonitor object is set to 'true' for that interface. Also, this object does not apply to the trunk side interfaces." ::= { cmPhyIfEntry 2 } cmPhyIfClockRate OBJECT-TYPE SYNTAX INTEGER(0..10312000) -- Units -- kHz ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the management client to set the clock rate across the client side interface. Due to hardware limitations, all values may not be supported. The default value of this object depends on the value of the cmPhyIfProtocol object. When the value of the cmPhyIfProtocol object is reset, the value of this object will be automatically set to the default for that protocol. In case of protocols that support multiple rates, the default value of this object will be the lowest rate possible for that protocol. For example, if the value of cmPhyIfProtocol is set to 'sonet', the default value of cmPhyIfClockRate is set to the OC-3 rate of 155520 kHz. If a non-default value is desired, then this object must be set after the cmPhyIfProtocol object has been reset. This object must be set to a supported clock rate when setting cmPhyIfProtocol to 'unknown'. In 2R mode of operation, this object is not applicable and will have a default value of 0. The value of this object cannot be modified when the cmPhyIfMonitor object is set to 'true' for that interface. Also, this object is not applicable to trunk side interfaces." ::= { cmPhyIfEntry 3 } cmPhyIfMonitor OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the management client to enable monitoring of the error counters on an interface, by writing a value of 'true' to this object. To bypass the monitoring hardware, a value of 'false' must be written to this object. Monitoring does not apply when the value of cmPhyIfProtocol is 'unknown'." ::= { cmPhyIfEntry 4 } cmPhyIfLoopback OBJECT-TYPE SYNTAX INTEGER { noLoop(1), diagnosticLoop(2), lineLoop(3), otherLoop(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the management client to configure loopback for the client side or trunk side interfaces. 'noLoop' - No Loopback present. 'diagnosticLoop' - This is an internal loopback, where the data stream is looped from the transmit to receive section. It is used for hardware debug, bring-up and diagnostics. 'lineLoop' - In this mode, the receive data stream is looped back to the transmit side. 'otherLoop' - This indicates loopbacks not defined here. The default value of this object will be 'noLoop'." ::= { cmPhyIfEntry 5 } cmPhyIfOFC OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the management client to enable OFC(Open Fibre Control) safety protocol for the client side interfaces, by writing a 'true' value to this object. A 'false' value would disable OFC. The default value of this object varies depending on the value of cmPhyIfProtocol and cmPhyIfClockRate. When cmPhyIfProtocol or cmPhyIfClockRate is reset, then the value of this object is automatically reset to the default value for that protocol or rate. If non-default OFC behavior is desired, then this object should be set after cmPhyIfProtocol or cmPhyIfClockRate has been reset. This object is not applicable to trunk side interfaces." ::= { cmPhyIfEntry 6 } cmPhyIfLaserSafetyControl OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS deprecated DESCRIPTION "This object allows the management client to enable laser safety control feature on the trunk side interfaces by writing a true value to this object. If laser safety control is enabled, the transmit laser on the trunk side is shut when the receive signal is not available on the fiber. A 'false' value disables this feature and is the default value assigned to this object. Laser safety control would not apply in case of splitter protection on the optical switch." ::= { cmPhyIfEntry 7 } cmPhyIfForwardLaserControl OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS deprecated DESCRIPTION "This object allows the management client to enable forward laser control on the client or trunk side interfaces by writing a true value to this object. If forward laser control is enabled, the transmit laser is shut when the cross-connect receive port on the switch is in alarm condition. A 'false' value disables this feature and is the default value assigned to this object." ::= { cmPhyIfEntry 8 } cmPhyIfTxBufferSize OBJECT-TYPE SYNTAX Gauge(0..65536) -- Units -- bytes ACCESS read-write STATUS mandatory DESCRIPTION "This object applies when circuit emulation of the client protocol is used. It allows the management client to configure the size of the transmit buffer on the client port. A value of 0 implies that this object does not apply to this interface. Controlling the size of the transmit buffer on a client port may be essential in scenarios where packet streams from various client ports are aggregated onto a single trunk port. The latency associated with an elementary stream received on a client port, from the trunk port is influenced by the nature of other elementary streams in the aggregate. For example, a giant packet in one stream will increase latency in processing packets in other elementary streams. The size of the transmit buffer on the client port must be configured proportional to this expected latency. Increasing the buffer size when latency is higher helps in reassembly of fragmented packets before transmitting them to the client device. Note that increasing the buffer size results in higher latency even when the elementary packet stream is not subject to high jitters. Refer to the platform specific documentation for guidelines on configuring this buffer size." ::= { cmPhyIfEntry 9 } cmPhyIfAutoNegotiation OBJECT-TYPE SYNTAX TriValue -- Rsyntax INTEGER { -- true(1), -- false(2), -- notApplicable(3) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the management client to enable auto negotiation signaling on the client side interface, by writing a 'true' value to this object. A 'false' value would disable auto negotiation. Setting the value 'notApplicable' to this object will not change the existing value in this object. Auto negotiation is applicable only for a few client protocols such as gigabitEthernet. If the client interface does not support 'auto negotiation' feature, then this object has the value of 'notApplicable' and the value will not be changed via a set operation." ::= { cmPhyIfEntry 10 } cmPhyIfTransType OBJECT-TYPE SYNTAX TransmissionType -- Rsyntax INTEGER { -- unknown(1), -- copper(2), -- optical(3) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object is used to identify the physical layer medium used for carrying data. For non-relevant interfaces, this value is 'unknown'." ::= { cmPhyIfEntry 11 } cmPhyIfRate OBJECT-TYPE SYNTAX CmRateType -- Rsyntax INTEGER { -- unknown(1), -- auto(2), -- oneGbps(3), -- twoGbps(4), -- fourGbps(5), -- tenGbps(6) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to specify the rate of the interface. The value of 'unknown' implies that this object does not apply to this interface." ::= { cmPhyIfEntry 12 } cmPhyIfNegotiatedRate OBJECT-TYPE SYNTAX CmNegotiatedRateType -- Rsyntax INTEGER { -- notApplicable(1), -- negotiating(2), -- oneGbps(3), -- twoGbps(4), -- fourGbps(5), -- tenGbps(6) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object is used to identify the current rate of the interface after the auto negotation. This object is valid only if the object cmPhyIfRate is configured as 'auto'." ::= { cmPhyIfEntry 13 } cmPhyIfOverSubscription OBJECT-TYPE SYNTAX TriValue -- Rsyntax INTEGER { -- true(1), -- false(2), -- notApplicable(3) -- } ACCESS read-write STATUS mandatory DESCRIPTION "Oversubscription allows the user to carry multiple clients over the trunk to efficiently utilize the trunk bandwidth. This object allows the management client to enable over subscription on an interface by setting a value of 'true' to this object. A 'false' value would disable over subscription. Setting the value 'notApplicable' to this object is not allowed. The value of 'notApplicable' implies that this object does not apply to this interface." DEFVAL { false } ::= { cmPhyIfEntry 14 } cmPhyIfClientSubrate OBJECT-TYPE SYNTAX Gauge(0..4240) -- Units -- mega-bytes-per-second ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the management client to specify the subrate bandwidth of the oversubscribed trunk which carries this client. A value of 0 implies that this object does not apply to this interface." DEFVAL { 0 } ::= { cmPhyIfEntry 15 } cmPhyIfClientSubrateLock OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the management client to lock the subrate bandwidth on an interface, by writing a value of 'true' to this object. A 'false' value would disable the bandwidth lock. If the clients bandwidth is locked then this client will not share its bandwidth with the other clients on the same oversubscribed trunk. SubrateLock does not apply when the value of cmPhyIfClientSubrate is zero." DEFVAL { false } ::= { cmPhyIfEntry 16 } cmPhyStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF CmPhyStatisticsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the cumulative error statistics being collected for the different medium types, except SONET, on the client side and an object for the optical power level on the trunk side. The error statistics for SONET are covered by the sonetSectionCurrentTable and the sonetSectionIntervalTable in the RFC1595-MIB." ::= { cmPhyStatistics 1 } cmPhyStatisticsEntry OBJECT-TYPE SYNTAX CmPhyStatisticsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the cmPhyStatisticsTable." INDEX { ifIndex } ::= { cmPhyStatisticsTable 1 } CmPhyStatisticsEntry ::= SEQUENCE { cmPhyRxPower INTEGER, cmPhyRxCVRD Counter, cmPhyRxCVRDOverflow Counter, cmPhyHCRxCVRD Counter, cmPhyRxHEC Counter, cmPhyRxHECOverflow Counter, cmPhyHCRxHEC Counter, cmPhyRxCRC Counter, cmPhyRxCRCOverflow Counter, cmPhyHCRxCRC Counter, cmPhyTxEncapFarEndPktErrors Counter, cmPhyTxEncapFarEndPktErrOverflow Counter, cmPhyHCTxEncapFarEndPktErrors Counter } cmPhyRxPower OBJECT-TYPE SYNTAX INTEGER(-4000..0) -- Units -- dBm ACCESS read-only STATUS deprecated DESCRIPTION "This object gives the optical power level received on the trunk side interface. The actual value of the power level received on the interface is the value of this object divided by 100. This object is not applicable to client side interfaces. This object has been deprecated since a similar object has been defined in the CISCO-OPTICAL-MONITOR-MIB." ::= { cmPhyStatisticsEntry 1 } cmPhyRxCVRD OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the lower word value of the counter associated with the number of code violations and running disparity errors encountered, in the receive direction. NOTE: The object cmPhyRxCVRDOverflow contains the higher 32 bits of this counter value. SNMP v2c or v3 managers can use the cmPhyHCRxCVRD object directly which is a 64 bit counter." ::= { cmPhyStatisticsEntry 2 } cmPhyRxCVRDOverflow OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the high word value of the counter associated with the number of code violations and running disparity errors encountered, in the receive direction. NOTE: The object cmPhyRxCVRD contains the lower 32 bits of this counter value. If the error count is greater than 4,294,967,295 the higher word value will be stored in this object. SNMP v2c or v3 managers can use the cmPhyHCRxCVRD object directly which is a 64 bit counter." ::= { cmPhyStatisticsEntry 3 } cmPhyHCRxCVRD OBJECT-TYPE SYNTAX --?? syntax is not convertable to SMIv1 Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the counter associated with the number of code violations and running disparity errors encountered, in the receive direction. This is a High Capacity (64 bit) version of the cmPhyRxCVRD counter." ::= { cmPhyStatisticsEntry 4 } cmPhyRxHEC OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "This object represents the lower word value of the counter associated with the number of CDL HEC errors encountered, in the receive direction. This object has a valid value only if the protocol type is gigabitEthernet/ tenGigabitEthernet. For all other protocols, this object is not applicable. NOTE: The object cmPhyRxHECOverflow contains the higher 32 bits of this counter value. SNMP v2c or v3 managers can use the cmPhyHCRxHEC object directly which is a 64 bit counter. This object has been deprecated since a similar object has been defined in the CISCO-CDL-MIB." ::= { cmPhyStatisticsEntry 5 } cmPhyRxHECOverflow OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "This object represents the high word value of the counter associated with the number of CDL HEC errors encountered, in the receive direction. This object has a valid value only if the protocol type is gigabitEthernet/ tenGigabitEthernet. For all other protocols, this object is not applicable. NOTE: The object cmPhyRxHEC contains the lower 32 bits of this counter value. If the error count is greater than 4,294,967,295 the higher word value will be stored in this object. SNMP v2c or v3 managers can use the cmPhyHCRxHEC object directly which is a 64 bit counter. This object has been deprecated since a similar object has been defined in the CISCO-CDL-MIB." ::= { cmPhyStatisticsEntry 6 } cmPhyHCRxHEC OBJECT-TYPE SYNTAX --?? syntax is not convertable to SMIv1 Counter ACCESS read-only STATUS deprecated DESCRIPTION "This object represents the counter associated with the number of CDL HEC errors encountered, in the receive direction. This object has a valid value only if the medium type is gigabitEthernet/ tenGigabitEthernet. For all other media, this object is not applicable. This is a High Capacity (64 bit) version of the cmPhyRxHEC counter. This object has been deprecated since a similar object has been defined in the CISCO-CDL-MIB." ::= { cmPhyStatisticsEntry 7 } cmPhyRxCRC OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the lower word value of the counter associated with CRC errors. This object has a valid value only for interfaces that provide CRC error monitoring. NOTE: The object cmPhyRxCRCOverflow contains the higher 32 bits of this counter value. SNMP v2c or v3 managers can use the cmPhyHCRxCRC object directly which is a 64 bit counter." ::= { cmPhyStatisticsEntry 8 } cmPhyRxCRCOverflow OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the higher word value of the counter associated with CRC errors. This object has a valid value only for interfaces that provide CRC error monitoring. NOTE: The object cmPhyRxCRC contains the lower 32 bits of this counter value. If the error count is greater than 4,294,967,295 the higher word value will be stored in this object. SNMP v2c or v3 managers can use the cmPhyHCRxCRC object directly which is a 64 bit counter." ::= { cmPhyStatisticsEntry 9 } cmPhyHCRxCRC OBJECT-TYPE SYNTAX --?? syntax is not convertable to SMIv1 Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the counter associated with CRC errors. This object has a valid value only for interfaces that provide CRC error monitoring. This is a High Capacity (64 bit) version of the cmPhyRxCRC counter." ::= { cmPhyStatisticsEntry 10 } cmPhyTxEncapFarEndPktErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the lower word value of the counter associated with ingress error indications from the far end of an Ethernet network, where an ESCON stream is encapsulated in Ethernet packets. This counter is incremented whenever an ESCON packet or control character has 8b/10b code violations or running disparity errors in the ingress direction at the far end of the Ethernet network. This object has a valid value only for ESCON interfaces where Ethernet encapsulation is performed. NOTE: The object cmPhyTxEncapFarEndPktErrOverflow contains the higher 32 bits of this counter value. SNMP v2c or v3 managers can use the cmPhyHCTxEsconPktInd object directly which is a 64 bit counter." ::= { cmPhyStatisticsEntry 11 } cmPhyTxEncapFarEndPktErrOverflow OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the higher word value of the counter associated with ingress error indications from the far end of an Ethernet network, where an ESCON stream is encapsulated in Ethernet packets. This counter is incremented whenever an ESCON packet or control character has 8b/10b code violations or running disparity errors in the ingress direction at the far end of the Ethernet network. This object has a valid value only for ESCON interfaces where Ethernet encapsulation is performed. NOTE: The object cmPhyTxEncapFarEndPktErrors contains the lower 32 bits of this counter value. SNMP v2c or v3 managers can use the cmPhyHCTxEsconPktInd object directly which is a 64 bit counter." ::= { cmPhyStatisticsEntry 12 } cmPhyHCTxEncapFarEndPktErrors OBJECT-TYPE SYNTAX --?? syntax is not convertable to SMIv1 Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the counter associated with ESCON ingress error indications from the far end of an Ethernet network, where an ESCON stream is encapsulated in Ethernet packets. This counter is incremented whenever an ESCON packet or control character has 8b/10b code violations or running disparity errors in the ingress direction at the far end of the Ethernet network. This object has a valid value only for ESCON interfaces where Ethernet encapsulation is performed. This is a High Capacity (64 bit) version of the cmPhyTxEncapFarEndPktErrors counter." ::= { cmPhyStatisticsEntry 13 } cmPhySonetSectionTraceTable OBJECT-TYPE SYNTAX SEQUENCE OF CmPhySonetSectionTraceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table provides objects for monitoring the J0 bytes of a SONET or SDH section." ::= { cmPhySonetSectionTrace 1 } cmPhySonetSectionTraceEntry OBJECT-TYPE SYNTAX CmPhySonetSectionTraceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the cmPhySonetSectionTraceTable is created when the value of the cmPhyIfProtocol object is set to 'sonet' and the value of cmPhyIfMonitor is set to 'true'." INDEX { ifIndex } ::= { cmPhySonetSectionTraceTable 1 } CmPhySonetSectionTraceEntry ::= SEQUENCE { cmPhySonetSectionTraceReceived OCTET STRING, cmPhySonetSectionTraceExpected OCTET STRING } cmPhySonetSectionTraceReceived OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object displays the SONET or SDH section trace bytes received at the interface." ::= { cmPhySonetSectionTraceEntry 1 } cmPhySonetSectionTraceExpected OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "This object defines the SONET or SDH section trace bytes to be expected at the interface. The default value of this object will be a zero length string." ::= { cmPhySonetSectionTraceEntry 2 } cmPhyIfGroup OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBGroups 1 } -- OBJECT-GROUP -- Status -- deprecated -- Descr -- The collection of objects to allow configurations and give -- information related to the physical layer characteristics -- of an interface. -- objects -- cmPhyIfMode, cmPhyIfProtocol, cmPhyIfClockRate, -- cmPhyIfMonitor, cmPhyIfLoopback, cmPhyIfOFC, -- cmPhyIfLaserSafetyControl, cmPhyIfForwardLaserControl cmPhyStatisticsGroup OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBGroups 2 } -- OBJECT-GROUP -- Status -- deprecated -- Descr -- The collection of objects used to monitor the protocol -- error counters on the client side and the power level -- received on the trunk side. -- objects -- cmPhyRxPower, cmPhyRxCVRD, cmPhyRxCVRDOverflow, cmPhyHCRxCVRD, -- cmPhyRxHEC, cmPhyRxHECOverflow, cmPhyHCRxHEC cmPhySonetSectionTraceGroup OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBGroups 3 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The objects used for monitoring the SONET section -- trace bytes. -- objects -- cmPhySonetSectionTraceReceived, -- cmPhySonetSectionTraceExpected cmPhyIf2Group OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBGroups 4 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The collection of objects to allow configurations and give -- information related to the physical layer characteristics -- of an interface. -- objects -- cmPhyIfMode, cmPhyIfProtocol, cmPhyIfClockRate, -- cmPhyIfMonitor, cmPhyIfLoopback, cmPhyIfOFC cmPhyCVRDErrorsGroup OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBGroups 5 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The collection of objects used to monitor the code violation -- and running disparity error counters. -- objects -- cmPhyRxCVRD, cmPhyRxCVRDOverflow, cmPhyHCRxCVRD cmPhyCRCErrorsGroup OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBGroups 6 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The collection of objects used to monitor CRC -- error counters. -- objects -- cmPhyRxCRC, cmPhyRxCRCOverflow, cmPhyHCRxCRC cmPhyEncapFarEndPktErrorsGroup OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBGroups 7 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The collection of objects used to monitor the -- far end ingress error indication counters for Ethernet- -- encapsulated ESCON streams. -- objects -- cmPhyTxEncapFarEndPktErrors, cmPhyTxEncapFarEndPktErrOverflow, -- cmPhyHCTxEncapFarEndPktErrors cmPhyIfTxBufferSizeGroup OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBGroups 8 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The collection of objects used to control size of -- transmit buffer. -- objects -- cmPhyIfTxBufferSize cmPhyIfAutoNegGroup OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBGroups 9 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The collection of objects used to control auto -- negotiation behavior. -- objects -- cmPhyIfAutoNegotiation cmPhyIfGroupSup1 OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBGroups 10 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The object that gives information related to transmission -- types on the client interface. -- objects -- cmPhyIfTransType cmPhyIfRateGroup OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBGroups 11 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The collection of objects that are used to retrieve and -- configure the various interface rates. -- objects -- cmPhyIfRate, cmPhyIfNegotiatedRate cmPhyIfClientOvsGroup OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBGroups 12 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The collection of objects to allow the oversubscription -- configurations on an interface. -- objects -- cmPhyIfOverSubscription cmPhyIfClientSubrateGroup OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBGroups 13 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The collection of objects to allow the configurations related -- to the subrating on an interface. -- objects -- cmPhyIfClientSubrate, cmPhyIfClientSubrateLock cmPhyMIBCompliance OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBCompliances 1 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- The compliance statement for platforms that monitor the -- operating status with respect to error -- counters, for the physical layer. -- Module -- >>current<< -- MandGroup -- cmPhyIfGroup -- MandGroup -- cmPhyStatisticsGroup -- OptGroup -- cmPhySonetSectionTraceGroup -- ObjVar -- cmPhyIfMode -- ObjVar -- cmPhyIfProtocol -- ObjVar -- cmPhyIfClockRate -- ObjVar -- cmPhyIfMonitor -- ObjVar -- cmPhyIfOFC cmPhyMIBCompliance2 OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBCompliances 2 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- The compliance statement for platforms that monitor the -- operating status with respect to error -- counters, for the physical layer. -- Module -- >>current<< -- MandGroup -- cmPhyIf2Group -- OptGroup -- cmPhyCVRDErrorsGroup -- OptGroup -- cmPhyCRCErrorsGroup -- OptGroup -- cmPhyEncapFarEndPktErrorsGroup -- OptGroup -- cmPhySonetSectionTraceGroup -- ObjVar -- cmPhyIfMode -- ObjVar -- cmPhyIfProtocol -- ObjVar -- cmPhyIfClockRate -- ObjVar -- cmPhyIfMonitor -- ObjVar -- cmPhyIfOFC cmPhyMIBCompliance3 OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBCompliances 3 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- The compliance statement for platforms that monitor the -- operating status with respect to error -- counters, for the physical layer. -- Module -- >>current<< -- MandGroup -- cmPhyIf2Group -- OptGroup -- cmPhyCVRDErrorsGroup -- OptGroup -- cmPhyCRCErrorsGroup -- OptGroup -- cmPhyEncapFarEndPktErrorsGroup -- OptGroup -- cmPhySonetSectionTraceGroup -- OptGroup -- cmPhyIfTxBufferSizeGroup -- ObjVar -- cmPhyIfMode -- ObjVar -- cmPhyIfProtocol -- ObjVar -- cmPhyIfClockRate -- ObjVar -- cmPhyIfMonitor -- ObjVar -- cmPhyIfOFC -- ObjVar -- cmPhyIfTxBufferSize cmPhyMIBComplianceRev4 OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBCompliances 4 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- The compliance statement for platforms that monitor the -- operating status with respect to error -- counters, for the physical layer. -- Module -- >>current<< -- MandGroup -- cmPhyIf2Group -- OptGroup -- cmPhyCVRDErrorsGroup -- OptGroup -- cmPhyCRCErrorsGroup -- OptGroup -- cmPhyEncapFarEndPktErrorsGroup -- OptGroup -- cmPhySonetSectionTraceGroup -- OptGroup -- cmPhyIfTxBufferSizeGroup -- OptGroup -- cmPhyIfAutoNegGroup -- ObjVar -- cmPhyIfMode -- ObjVar -- cmPhyIfProtocol -- ObjVar -- cmPhyIfClockRate -- ObjVar -- cmPhyIfMonitor -- ObjVar -- cmPhyIfOFC -- ObjVar -- cmPhyIfTxBufferSize -- ObjVar -- cmPhyIfAutoNegotiation cmPhyMIBComplianceRev5 OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBCompliances 5 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- The compliance statement for platforms that monitor the -- operating status with respect to error -- counters, for the physical layer. -- Module -- >>current<< -- MandGroup -- cmPhyIf2Group -- OptGroup -- cmPhyCVRDErrorsGroup -- OptGroup -- cmPhyCRCErrorsGroup -- OptGroup -- cmPhyEncapFarEndPktErrorsGroup -- OptGroup -- cmPhySonetSectionTraceGroup -- OptGroup -- cmPhyIfTxBufferSizeGroup -- OptGroup -- cmPhyIfAutoNegGroup -- OptGroup -- cmPhyIfGroupSup1 -- ObjVar -- cmPhyIfMode -- ObjVar -- cmPhyIfProtocol -- ObjVar -- cmPhyIfClockRate -- ObjVar -- cmPhyIfMonitor -- ObjVar -- cmPhyIfOFC -- ObjVar -- cmPhyIfTxBufferSize -- ObjVar -- cmPhyIfAutoNegotiation cmPhyMIBComplianceRev6 OBJECT IDENTIFIER ::= { ciscoMetroPhyMIBCompliances 6 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- The compliance statement for platforms that monitor the -- operating status with respect to error -- counters, for the physical layer. -- Module -- >>current<< -- MandGroup -- cmPhyIf2Group -- OptGroup -- cmPhyCVRDErrorsGroup -- OptGroup -- cmPhyCRCErrorsGroup -- OptGroup -- cmPhyEncapFarEndPktErrorsGroup -- OptGroup -- cmPhySonetSectionTraceGroup -- OptGroup -- cmPhyIfTxBufferSizeGroup -- OptGroup -- cmPhyIfAutoNegGroup -- OptGroup -- cmPhyIfGroupSup1 -- OptGroup -- cmPhyIfRateGroup -- OptGroup -- cmPhyIfClientOvsGroup -- OptGroup -- cmPhyIfClientSubrateGroup -- ObjVar -- cmPhyIfMode -- ObjVar -- cmPhyIfProtocol -- ObjVar -- cmPhyIfClockRate -- ObjVar -- cmPhyIfMonitor -- ObjVar -- cmPhyIfOFC -- ObjVar -- cmPhyIfTxBufferSize -- ObjVar -- cmPhyIfAutoNegotiation -- ObjVar -- cmPhyIfRate -- ObjVar -- cmPhyIfOverSubscription -- ObjVar -- cmPhyIfClientSubrate -- ObjVar -- cmPhyIfClientSubrateLock END